Statistical analysis of adsorption isotherm models and its appropriate selection

被引:203
作者
Rajahmundry, Ganesh Kumar [1 ]
Garlapati, Chandrasekhar [1 ]
Kumar, Ponnusamy Senthil [2 ]
Alwi, Ratna Surya [3 ]
Vo, Dai-Viet N. [4 ]
机构
[1] Puducherry Technol Univ, Dept Chem Engn, Pondicherry 605014, India
[2] Sri Sivasubramaniya Nadar Coll Engn, Dept Chem Engn, Chennai 603110, Tamil Nadu, India
[3] Fajar Univ, Dept Chem Engn, Sulawesi Selatan 90231, Indonesia
[4] Nguyen Tat Thanh Univ, Ctr Excellence Green Energy & Environm Nanomat CE, Ho Chi Minh City, Vietnam
关键词
Adsorbate; Adsorbent; AIC(corrected); Correlations; Isotherm models; ACTIVATED CARBON; AQUEOUS-SOLUTION; REMOVAL; EQUILIBRIUM; BIOSORPTION; KINETICS; ACIDS; IONS; DYE;
D O I
10.1016/j.chemosphere.2021.130176
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In adsorption research, there was a good amount of adsorption data on various absorbent-adsorbate systems and many isotherm models were studied but there was no study on applicability of models to a group of adsorbent-adsorbate systems. In order to establish this, adsorption data obtained from literature for activated carbon with different solutes/sorbate(s) were considered and modelled with various adsorption models. The molecular mass of the solutes varies from 78.118(Benzene) to 932(Direct blue 2B dye) g.mol(-1) and adsorbent surface area varies from 516 to 1100 m(2) g(-1). In this work, twelve commonly known isotherms models were employed to correlate the adsorption data. For modelling polymath (R) software has been used. The input data for the polymath (R) software were amount of adsorbate per unit amount of adsorbent, q(e) vs. concentration, c(e). Nonlinear optimization of isotherm data gives model parameters. The correlating ability of the various models was compared in terms of arithmetic average relative deviation (AARD) calculated based on q(e). The lowest overall AARD% values were observed for Baudu Isotherm and Langmuir-Freundlich and the corresponding AARD% values were 2.6 and 2.8 respectively. The highest overall AARD% value was observed for Marczewski-jaroniec isotherm and the corresponding AARD% is 23.5. Corrected Akaike's information criterion (AIC(corrected)) was employed to known the best model. We observed lowest AIC(corrected)(15.859) value for LangmuirFreundlich isotherm and the highest AIC(corrected)(59.283) value for Marczewski-jaroniec isotherm. AIC(corrected) reveals that Langmuir-Freundlich isotherm was efficient in correlating the isotherm data. Further, Pair-t test was performed between Baudu isotherm and other model. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:7
相关论文
共 44 条
[1]  
Adamson AW, 1967, PHYS CHEM SURFACES
[2]   Removal of cyanide from aqueous solution using impregnated activated carbon [J].
Adhoum, N ;
Monser, L .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2002, 41 (01) :17-21
[3]   Information Theory and an Extension of the Maximum Likelihood Principle [J].
Akaike, Hirotogu .
Trees - Structure and Function, 2015, 29 (06) :655-662
[4]   Removal of direct blue-106 dye from aqueous solution using new activated carbons developed from pomegranate peel: Adsorption equilibrium and kinetics [J].
Amin, Nevine Kamal .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 165 (1-3) :52-62
[5]   Modelling and Interpretation of Adsorption Isotherms [J].
Ayawei, Nimibofa ;
Ebelegi, Augustus Newton ;
Wankasi, Donbebe .
JOURNAL OF CHEMISTRY, 2017, 2017
[6]  
Baudu M, 1990, APPL 723 REGENERATIO
[7]   On the optimal use of isotherm models for the characterization of biosorption of lead onto algae [J].
Brouers, F. ;
Al-Musawi, Tariq J. .
JOURNAL OF MOLECULAR LIQUIDS, 2015, 212 :46-51
[8]   Adsorption of gases in multimolecular layers [J].
Brunauer, S ;
Emmett, PH ;
Teller, E .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1938, 60 :309-319
[9]   Multimodel inference - understanding AIC and BIC in model selection [J].
Burnham, KP ;
Anderson, DR .
SOCIOLOGICAL METHODS & RESEARCH, 2004, 33 (02) :261-304
[10]   Adsorption isotherms of benzoic acid onto activated carbon and breakthrough curves in fixed-bed columns [J].
Chern, JM ;
Chien, YW .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2001, 40 (17) :3775-3780