摘要
Since 2001 the femtosecond laser has primarily been used in refractive surgery, e. g., for lasik, implantation of intracorneal ring segments or antiastigmatic corneal incisions. However, the femtosecond laser is more and more used for therapeutic reasons in corneal surgery. In this context it is used for profiled trephinations in penetrating keratoplasty where various profiles of the cutting edge can be designed (e. g., tophat profile, mushroom profile, zig-zag profile). The potential advantages of these profiles include improved graft adaptation, better and more stable wound healing leading to earlier suture removal and eventually prolonged graft survival. However, none of these potential advantages has been demonstrated by reliable study results until now. First clinical experiences show that much earlier suture removal is possible without significant complications. However, with sutures in there seems to be no advantage of the femtosecond laser compared to mechanically guided trephination systems regarding visual acuity and postoperative astigmatism. Besides penetrating profiles, the femtosecond laser also allows for lamellar cuts. As deep anterior lamellar keratoplasty can only be supported by the femtosecond laser, it is mostly used for posterior lamellar grafts in this context. However, first clinical results using the femtosecond laser for DSAEK (descemet stripping automated endothelial keratoplasty) are poorer than those using microkeratome-prepared lamellar grafts for DSAEK.
引用
收藏
页码:453 / 459
页数:7
相关论文
共 50 条
  • [21] VisuMax (R) femtosecond laser for corneal refractive surgery
    Montes-Mico, Robert
    Cervino, Alejandro
    Ferrer-Blasco, Teresa
    EXPERT REVIEW OF OPHTHALMOLOGY, 2008, 3 (04) : 385 - 388
  • [22] Efficacy and Safety of Femtosecond Laser-Assisted Corneal Endothelial Keratoplasty: A Randomized Multicenter Clinical Trial
    Cheng, Yanny Y. Y.
    Schouten, Jan S. A. G.
    Tahzib, Nayyirih G.
    Wijdh, Robert-Jan
    Pels, Elisabeth
    van Cleynenbreugel, Hugo
    Eggink, Catharina A.
    Rijneveld, Wilhelmina J.
    Nuijts, Rudy M. M. A.
    TRANSPLANTATION, 2009, 88 (11) : 1294 - 1302
  • [23] Effects of corneal irregular astigmatism on visual acuity after conventional and femtosecond laser-assisted Descemet's stripping automated endothelial keratoplasty
    Tomida, Daisuke
    Yamaguchi, Takefumi
    Ogawa, Akiko
    Hirayama, Yumiko
    Shimazaki-Den, Seika
    Satake, Yoshiyuki
    Shimazaki, Jun
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2015, 59 (04) : 216 - 222
  • [24] Femtosecond and excimer laser-assisted endothelial keratoplasty (FELEK): A new technique of endothelial transplantation
    Trinh, L.
    Saubamea, B.
    Auclin, F.
    Denoyer, A.
    Lai-Kuen, R.
    El Hamdaoui, M.
    Labbe, A.
    Despiau, M-C.
    Brignole-Baudouin, F.
    Baudouin, C.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2014, 37 (03): : 211 - 219
  • [25] New developments in corneal refractive surgery with femtosecond laser pulses
    Le Harzic, Ronan
    Martin, Sven
    Bückle, Rainer
    Wüllner, Christian
    Donitzky, Christof
    Riemann, Iris.
    König, Karsten
    OPHTHALMIC TECHNOLOGIES XVI, 2006, 6138
  • [26] Comparison of femtosecond laser-assisted corneal intrastromal xenotransplantation and the allotransplantation in rhesus monkeys
    Jin, He
    Liu, Liangping
    Ding, Hui
    He, Miao
    Zhang, Chi
    Zhong, Xingwu
    BMC OPHTHALMOLOGY, 2017, 17
  • [27] Laser parameters, focusing optics, and side effects in femtosecond laser corneal surgery
    Plamann, Karsten
    Nuzzo, Valeria
    Peyrot, Donald A.
    Deloison, Florent
    Savoldelli, Michele
    Legeais, Jean-Marc
    OPHTHALMIC TECHNOLOGIES XVIII, 2008, 6844
  • [28] Human Retina Model for Laser Safety during Corneal Surgery with a Femtosecond Laser
    Sun, Hui
    Fan, Zhongwei
    2016 INTERNATIONAL CONFERENCE LASER OPTICS (LO), 2016,
  • [29] Experimental corneal imaging and corneal surgery with non-amplified femtosecond laser pulses
    Huss, C.
    Krause, M.
    Loew, U.
    Riemann, I.
    Stracke, F.
    Mestres, P.
    Seitz, B.
    Koenig, K.
    OPHTHALMOLOGE, 2012, 109 (10): : 995 - 1000
  • [30] Preparing Uniform-Thickness Corneal Endothelial Grafts from Donor Tissues Using a Non-Amplified Femtosecond Laser
    Singh, Kanwarpal
    Haydari, Nour
    Brunette, Isabelle
    Costantino, Santiago
    PLOS ONE, 2013, 8 (12):