Towards Improved Healthcare Performance: Examining Technological Possibilities and Patient Satisfaction with Wireless Body Area Networks

被引:23
作者
Fensli, Rune [1 ,2 ]
Dale, Jan Gunnar [3 ]
O'Reilly, Philip
O'Donoghue, John [1 ]
Sammon, David [1 ]
Gundersen, Torstein [4 ]
机构
[1] Univ Coll Cork, Cork, Ireland
[2] Univ Agder, Fac Sci & Engn, Grimstad, Norway
[3] Univ Agder, Fac Hlth & Sport, Arendal, Norway
[4] Sorlandet Hosp HF, Dept Med, Arendal, Norway
关键词
Wireless BANs; Electrocardiography; Arrhythmia diagnostics; Patient satisfaction; Remote patient monitoring; ACCEPTANCE;
D O I
10.1007/s10916-009-9291-8
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
This paper investigates the benefits of using less intrusive wireless technologies for heart monitoring. By replacing well established heart monitoring devices (i.e. Holter) with wireless ECG based Body Area Networks (BAN), improved healthcare performance can be achieved, reflected in (1) high quality ECG recordings during physical activities and (2) increased patient satisfaction. A small scale clinical trial was conducted to compare both technologies and the results illustrate that the wireless ECG monitor was able to detect ECG signals intended for arrhythmia diagnostics. Furthermore, from a patient's perspective, both technologies were evaluated using three dimensions, namely; hygienic aspects, physical activity, and skin reactions. Results demonstrate that the wireless ECG BAN showed better performance, especially regarding the hygienic aspects. It was also favourable for use during physical activities, and the signal quality of the wireless sensor system demonstrated good performance regarding signal noise and artefact disturbances. This paper concludes that wireless cardiac monitoring systems have significant benefits from a patient's perspective, and further clinical trials should be conducted to further evaluate the new ECG based BAN system, to identify the possibility of widespread adoption and utilisation of wireless technology for arrhythmia diagnostics.
引用
收藏
页码:767 / 775
页数:9
相关论文
共 26 条
[1]  
ALKHATIB I, 2007, LNCS, V4050, P239
[2]  
ANDREASSON J, 2002, SENS 02 P IEEE
[3]   AMON:: A wearable multiparameter medical monitoring and alert system [J].
Anliker, U ;
Ward, JA ;
Lukowicz, P ;
Tröster, G ;
Dolveck, F ;
Baer, M ;
Keita, F ;
Schenker, EB ;
Catarsi, F ;
Coluccini, L ;
Belardinelli, A ;
Shklarski, D ;
Alon, M ;
Hirt, E ;
Schmid, R ;
Vuskovic, M .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2004, 8 (04) :415-427
[4]  
[Anonymous], 1985, PHENOMENOLOGY PSYCHO
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Long-term outcomes of out-of-hospital cardiac arrest after successful early defibrillation [J].
Bunch, TJ ;
White, RD ;
Gersh, BJ ;
Meverden, RA ;
Hodge, DO ;
Ballman, KV ;
Hammill, SC ;
Shen, WK ;
Packer, DL .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (26) :2626-2633
[7]   Pilot study of objective cough monitoring in infants [J].
Corrigan, DL ;
Paton, JY .
PEDIATRIC PULMONOLOGY, 2003, 35 (05) :350-357
[8]  
Demiris George, 2004, Int J Electron Healthc, V1, P4, DOI 10.1504/IJEH.2004.004655
[9]  
FENSKE S, 2007, CHALLENGES OPPORTUNI
[10]   Sensor acceptance model - Measuring patient acceptance of wearable sensors [J].
Fensli, R. ;
Pedersen, P. E. ;
Gundersen, T. ;
Hejlesen, O. .
METHODS OF INFORMATION IN MEDICINE, 2008, 47 (01) :89-95