Electrochemical DNA biosensor based on chitosan/nano-V2O5/MWCNTs composite film modified carbon ionic liquid electrode and its application to the LAMP product of Yersinia enterocolitica gene sequence

被引:143
|
作者
Sun, Wei [1 ]
Qin, Peng [1 ]
Gao, Hongwei [2 ]
Li, Guicun [3 ]
Jiao, Kui [1 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Shandong, Peoples R China
[2] Shandong Entry Exit Inspect & Quarantine Bur Peop, Qingdao 266042, Peoples R China
[3] Qingdao Univ Sci & Technol, Key Lab Nanostruct Mat, Qingdao 266042, Peoples R China
基金
中国国家自然科学基金;
关键词
V2O5; nanobelt; Multi-walled carbon nanotubes; Chitosan; Carbon ionic liquid electrode; Electrochemical DNA biosensor; MEDIATED ISOTHERMAL AMPLIFICATION; VANADIUM-OXIDE; PAT GENE; HYBRIDIZATION; CHITOSAN; HEMOGLOBIN; NANOTUBES; ELECTROCATALYSIS; NANOPARTICLES; SENSOR;
D O I
10.1016/j.bios.2009.10.011
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new electrochemical DNA biosensor was fabricated by using a V2O5 nanobelts (nano-V2O5), Multiwalled carbon nanotubes (MWCNTs) and chitosan (CTS) nanocomposite materials modified carbon ionic liquid electrode (CILE) as the working electrode. The CILE was prepared by using N-hexylpyridinium hexafluorophosphate (HPPF6) as the binder with the graphite powder. The CTS-V2O5-MWCNTs/CILE was used as the basal electrode for the immobilization of the single-stranded DNA (ssDNA) probe. After the hybridization with the target ssDNA sequence, the electrochemical indicator of methylene blue (MB) was used to monitor the hybridization reaction. Experimental data indicated that the synergistic effect of nano-V2O5 and MWCNTs increased the amounts of ssDNA adsorbed on the electrode surface and resulted in the corresponding increase of the electrochemical responses. This DNA biosensor combined the advantages such as the biocompatibility of V2O5 nanobelt, the excellent electron transfer ability of MWCNTs, the good film-forming ability of CTS and the high conductivity of CILE. Under the optimal conditions differential pulse voltammetry (DPV) was used to record the electrochemical response of MB and the specific ssDNA sequence could be detected in the concentration range from 1.0 x 10(-11) to 1.0 x 10(-6) mol L-1 with the detection limit as 1.76 x 10-11 mol L-1 (3 sigma). The DNA biosensor showed good stability and discrimination ability to the one-base and three-base mismatched ssDNA sequence. The loop-mediated isothermal amplification (LAMP) product of Yersinia enterocolitica gene sequence in pork meat was detected by the proposed method with satisfactory result, suggesting that the CTS-V2O5-MWCNTs/ClLE had the potential for the sensitive detection of specific gene sequence. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1264 / 1270
页数:7
相关论文
共 20 条
  • [1] Electrochemical horseradish peroxidase biosensor based on dextran-ionic liquid-V2O5 nanobelt composite material modified carbon ionic liquid electrode
    Zhu, Zhihong
    Sun, Xiaoying
    Wang, Yan
    Zeng, Yan
    Sun, Wei
    Huang, Xintang
    MATERIALS CHEMISTRY AND PHYSICS, 2010, 124 (01) : 488 - 492
  • [2] Application of chitosan/Fe3O4 microsphere-graphene composite modified carbon ionic liquid electrode for the electrochemical detection of the PCR product of soybean Lectin gene sequence
    Sun, Wei
    Qi, Xiaowei
    Chen, Ying
    Liu, Shengyun
    Gao, Hongwei
    TALANTA, 2011, 87 : 106 - 112
  • [3] Electrochemical Biosensor Based on Carbon Ionic Liquid Electrode Modified with Nafion/Hemoglobin/DNA Composite Film
    Sun, Wei
    Wang, Yan
    Li, Xiaoqing
    Wu, Jie
    Zhan, Tianrong
    Jiao, Kui
    ELECTROANALYSIS, 2009, 21 (22) : 2454 - 2460
  • [4] Electrochemical myoglobin biosensor based on carbon ionic liquid electrode modified with Fe3O4@SiO2 microsphere
    Wang, Xiaofeng
    You, Zheng
    Sha, Hailiang
    Sun, Zhaolan
    Sun, Wei
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2014, 18 (01) : 207 - 213
  • [5] Electrochemical DNA Biosensor Based on Partially Reduced Graphene Oxide Modified Carbon Ionic Liquid Electrode for the Detection of Transgenic Soybean A2704-12 Gene Sequence
    Sun, Wei
    Zhang, Yuanyuan
    Hu, Anhui
    Lu, Yongxi
    Shi, Fan
    Lei, Bingxin
    Sun, Zhenfan
    ELECTROANALYSIS, 2013, 25 (06) : 1417 - 1424
  • [6] Development of a Highly Sensitive DNA Electrochemical Biosensor for the Determination of Escherichia coli Based on Nano-MnO2/Chitosan/Ionic Liquid Film Composites
    Liu, Zhi-Min
    Cao, Yan-Yan
    Li, Zhe-Jian
    Shen, Guo-Li
    Yu, Ru-Qin
    SENSOR LETTERS, 2011, 9 (02) : 563 - 569
  • [7] Electrochemistry of Hemoglobin in the Chitosan and TiO2 Nanoparticles Composite Film Modified Carbon Ionic Liquid Electrode and Its Electrocatalysis
    Sun, Wei
    Li, Xiaoqing
    Liu, Shufeng
    Jiao, Kui
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2009, 30 (03): : 582 - 588
  • [8] Electrochemical oxidation of adenosine-5′-triphosphate on a chitosan-graphene composite modified carbon ionic liquid electrode and its determination
    Sun, Wei
    Liu, Jun
    Wang, Xiuzhen
    Li, Tongtong
    Li, Guangjiu
    Wu, Jie
    Zhang, Liqi
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (07): : 2129 - 2134
  • [9] Electrochemistry of hemoglobin in the chitosan and TiO2 nanoparticles composite film modified carbon ionic liquid electrode and its electrocatalysis
    Sun, Wei
    Li, Xiaoqing
    Liu, Shufeng
    Jiao, Kui
    Bulletin of the Korean Chemical Society, 2009, 30 (03) : 582 - 588
  • [10] Sensitive Determination of 4-Nitrophenol Based on Multi-Walled Carbon Nano-Tube/Ionic Liquid/Chitosan Composite Film Modified Electrode
    Chen, J.
    Yang, G.
    Chen, M.
    Li, W.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2009, 45 (11) : 1287 - 1291