In the paper GUM-Dw3 graphite-walled cylindrical cavity ionization chamber (of design and volume typical for the chambers for radiation therapy dosimetry) was presented as a realization of an ionometric standard for absorbed dose to water. A state-of-the-art uncertainty budget and results of comparison to GUMs standards has been presented. Good agreement of absorbed dose to water with reference standard, with relative deviation of 0.28%, and standard uncertainty (k=2) of 0.48% indicates good quality of the GUM-Dw3 as a primary standard. This paper describes the step-by-step procedure to calculate a perturbation factor, that is a crucial issue for ionometric measurement of absorbed dose to water. Capabilities of FLUKA code for this factor determination have been also investigated.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] THE GRAPHITE CALORIMETER AS A STANDARD OF ABSORBED DOSE FOR CO-60 GAMMA-RADIATION
    PRUITT, JS
    DOMEN, SR
    LOEVINGER, R
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1981, 86 (05): : 495 - 502
  • [2] IONOMETRIC DETERMINATION OF ABSORBED DOSE TO WATER FOR CO-60 GAMMA-RAYS
    BOUTILLON, M
    PERROCHE, AM
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (03): : 439 - 454
  • [3] PERTURBATION CORRECTION FOR THE IONOMETRIC DETERMINATION OF ABSORBED DOSE IN A GRAPHITE PHANTOM FOR CO-60 GAMMA-RAYS
    BOUTILLON, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (04): : 375 - 388
  • [4] GRAPHITE IONIZATION CHAMBER AS A LABORATORY STANDARD OF ABSORBED DOSE
    LAMPERTI, PJ
    LOEVINGE.R
    PHYSICS IN MEDICINE AND BIOLOGY, 1971, 16 (01): : 172 - &
  • [5] CALORIMETER AND IONIZATION-CHAMBER MEASUREMENTS OF ABSORBED DOSE IN CO-60 AND PROTON THERAPY BEAMS
    VERHEY, LJ
    MCDONALD, JC
    MA, I
    SMITH, AR
    MEDICAL PHYSICS, 1981, 8 (04) : 573 - 573
  • [6] GRAPHITE CALORIMETER IN WATER PHANTOM AND CALIBRATION OF IONIZATION CHAMBERS IN DOSE TO WATER FOR CO-60 GAMMA-RADIATION
    RAO, ISS
    NAIK, SB
    MEDICAL PHYSICS, 1980, 7 (03) : 196 - 201
  • [7] GAP CORRECTION FOR THE CALORIMETRIC MEASUREMENT OF ABSORBED DOSE IN GRAPHITE WITH A CO-60 BEAM
    BOUTILLON, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (12): : 1809 - 1821
  • [8] Comparisons of air kerma and absorbed dose to water standards in Co-60 radiation beams for radiotherapy
    Kottler, Christian
    Steurer, Andreas
    Delaunay, Frank
    de Pooter, Jacco
    Mulas, Cristina Garcia
    Mihailescu, Liviu-Cristian
    METROLOGIA, 2020, 57 (1A)
  • [9] Performance evaluation of graphite pancake ionization chamber by comparing the absorbed dose to water calibration
    Lee, JH
    Lin, CY
    Wang, CF
    Butler, DJ
    Webb, DV
    Yeh, CY
    Hwang, WS
    RADIATION MEASUREMENTS, 2006, 41 (03) : 306 - 316
  • [10] COMPUTATION OF ABSORBED DOSE DISTRIBUTION IN CO-60 TELETHERAPY
    CUZINO, S
    MOLDOVAN, N
    SZAKATS, M
    MATACHE, G
    REVUE ROUMAINE DE PHYSIQUE, 1975, 20 (01): : 107 - 113