Evaluation of airborne particulate matter and metals data in personal, indoor and outdoor environments using ED-XRF and ICP-MS and co-located duplicate samples

被引:64
作者
Niu, Jianjun [1 ]
Rasmussen, Pat E. [1 ,2 ]
Wheeler, Amanda [3 ]
Williams, Ron [4 ]
Chenier, Marc [1 ]
机构
[1] Hlth Canada, HECSB, Environm Hlth Sci Res Bur, Safe Environm Programme, Ottawa, ON K1A 0K9, Canada
[2] Univ Ottawa, Dept Earth Sci, Ottawa, ON K1N 6N5, Canada
[3] Hlth Canada, Water Air & Climate Change Bur, Safe Environm Programme, HECSB, Ottawa, ON K1A 0P8, Canada
[4] US EPA, Natl Exposure Res Lab, Res Triangle Pk, NC 27711 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Particulate matter; Uncertainty; Metals; Exposure assessment; Air pollution; ICP-MS; ED-XRF; EXPOSURE; UNCERTAINTY; PB; CR; CD;
D O I
10.1016/j.atmosenv.2009.10.009
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Factors and sources affecting measurement uncertainty associated with monitoring metals in airborne particulate matter (PM) were investigated as part of the Windsor, Ontario Exposure Assessment Study (WOEAS). The assessment was made using co-located duplicate samples and a comparison of two analytical approaches: ED-XRF and ICP-MS. Sampling variability was estimated using relative percent difference (RPD) of co-located duplicate samples. The comparison of ICP-MS and ED-XRF results yields very good correlations (R-2 >= 0.7) for elements present at concentrations that pass both ICP-MS and ED-XRF detection limits (e.g. Fe, Mn, Zn. Pb and Cu). PM concentration ranges (median, sample number) of 24-h indoor PM10 and personal PM10 filters, and outdoor PM2.5 filters were determined to be 2.2-40.7 (11.0, n = 48) mu g m(-3), 8.0-48.3 (11.9, n = 48) mu g m(-3), and 17.1-42.3 (21.6, n = 18) mu g m(-3), respectively. The gravimetric analytical results reveal that the variations in PM mass measurements for same-day sampling are insignificant compared to temporal or spatial variations: 92%, 100% and 96% of indoor, outdoor and personal duplicate samples, respectively, pass the quality criteria (RPD <= 20%). Uncertainties associated with ED-XRF elemental measurements of S, Ca, Mn, Fe and Zn for 24-h filter samples are low: 78%-100% of the duplicate samples passed the quality criteria. In the case of 24-h filter samples using ICP-MS, more elements passed the quality criteria due to the lower detection limits. These were: Li, Na, K, Ca, Si,Al, V. Fe, Mn, Co, Cu, Mo, Ag, Zn, Pb,As, Mg, Sb, Sn, Sr, Th, Ti, TI, and U. Low air concentrations of metals (near or below instrumental detection limits) and/or inadvertent introduction of metal contamination are the main causes for excluding elements based on the pass/fail criteria. Uncertainty associated with elemental measurements must be assessed on an element-by-element basis. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:235 / 245
页数:11
相关论文
共 42 条
[1]   Size distributions of trace metals in atmospheric aerosols in the United Kingdom [J].
Allen, AG ;
Nemitz, E ;
Shi, JP ;
Harrison, RM ;
Greenwood, JC .
ATMOSPHERIC ENVIRONMENT, 2001, 35 (27) :4581-4591
[2]  
[Anonymous], [No title captured]
[3]  
BRANIS M, 2005, 2005 EV ASS C EAC 20, P535
[4]   Atomic spectrometry update. Environmental analysis [J].
Butler, Owen T. ;
Cook, Jennifer M. ;
Harrington, Chris F. ;
Hill, Steve J. ;
Rieuwerts, John ;
Miles, Douglas L. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (02) :249-286
[5]   Atomic spectrometry update. Environmental analysis [J].
Butler, Owen T. ;
Cook, Jennifer M. ;
Davidson, Christine M. ;
Harrington, Chris F. ;
Miles, Douglas L. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (02) :131-177
[6]  
BUTTERFIELD D, 2007, NPL REPORT AS, V15, P1
[7]  
*CESI, 2008, HIGHL
[8]   Bioavailable transition metals in particulate matter mediate cardiopulmonary injury in healthy and compromised animal models [J].
Costa, DL ;
Dreher, KL .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1997, 105 :1053-1060
[9]   Development and laboratory performance evaluation of a personal multipollutant sampler for simultaneous measurements of particulate and gaseous pollutants [J].
Demokritou, P ;
Kavouras, IG ;
Ferguson, ST ;
Koutrakis, P .
AEROSOL SCIENCE AND TECHNOLOGY, 2001, 35 (03) :741-752
[10]   A COMPOSITE RECEPTOR METHOD APPLIED TO PHILADELPHIA AEROSOL [J].
DZUBAY, TG ;
STEVENS, RK ;
GORDON, GE ;
OLMEZ, I ;
SHEFFIELD, AE ;
COURTNEY, WJ .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1988, 22 (01) :46-52