Liquid matrix deposition on conductive hydrophobic surfaces for tuning and quantitation in UV-MALDI mass spectrometry

被引:34
作者
Palmblad, Magnus [1 ]
Cramer, Rainer [1 ]
机构
[1] Univ Reading, BioCtr, Reading RG6 6AS, Berks, England
关键词
D O I
10.1016/j.jasms.2006.11.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
With its highly fluctuating ion production matrix-assisted laser desorption/ionization (MALDI) poses many practical challenges for its application in mass spectrometry. Instrument tuning and quantitative ion abundance measurements using ion signal alone depend on a stable ion beam. Liquid MALDI matrices have been shown to be a promising alternative to the commonly used solid matrices. Their application in areas where a stable ion current is essential has been discussed but only limited data have been provided to demonstrate their practical use and advantages in the formation of stable MALDI ion beams. In this article we present experimental data showing high MALDI ion beam stability over more than two orders of magnitude at high analytical sensitivity (low femtomole amount prepared) for quantitative peptide abundance measurements and instrument tuning in a MALDI Q-TOF mass spectrometer. Samples were deposited on an inexpensive conductive hydrophobic surface and shrunk to droplets < 10 nL in size. By using a sample droplet < 10 nL it was possible to acquire data from a single irradiated spot for roughly 10,000 shots with little variation in ion signal intensity at a laser repetition rate of 5-20 Hz.
引用
收藏
页码:693 / 697
页数:5
相关论文
共 19 条
[1]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[2]   Ionic liquids as matrixes for matrix-assisted laser desorption/ionization mass spectrometry [J].
Armstrong, DW ;
Zhang, LK ;
He, LF ;
Gross, ML .
ANALYTICAL CHEMISTRY, 2001, 73 (15) :3679-3686
[3]   Liquid ultraviolet matrix-assisted laser desorption/ionization mass spectrometry for automated proteomic analysis [J].
Cramer, R ;
Corless, S .
PROTEOMICS, 2005, 5 (02) :360-370
[4]   High-throughput proteomics using matrix-assisted laser desorption/ionization mass spectrometry [J].
Cramer, R ;
Gobom, J ;
Nordhoff, E .
EXPERT REVIEW OF PROTEOMICS, 2005, 2 (03) :407-420
[5]  
Cramer R, 2000, RAPID COMMUN MASS SP, V14, P53
[6]   α-cyano-4-hydroxycinnamic acid affinity sample preparation.: A protocol for MALDI-MS peptide analysis in proteomics [J].
Gobom, J ;
Schuerenberg, M ;
Mueller, M ;
Theiss, D ;
Lehrach, H ;
Nordhoff, E .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :434-438
[7]   IMPROVEMENT OF SIGNAL REPRODUCIBILITY AND MATRIX/COMATRIX EFFECTS IN MALDI ANALYSIS [J].
GUSEV, AI ;
WILKINSON, WR ;
PROCTOR, A ;
HERCULES, DM .
ANALYTICAL CHEMISTRY, 1995, 67 (06) :1034-1041
[8]   Automation of matrix-assisted laser desorption/ionization mass spectrometry using fuzzy logic feedback control [J].
Jensen, ON ;
Mortensen, P ;
Vorm, O ;
Mann, M .
ANALYTICAL CHEMISTRY, 1997, 69 (09) :1706-1714
[9]   CONTINUOUS-FLOW MATRIX-ASSISTED LASER DESORPTION IONIZATION MASS-SPECTROMETRY [J].
LI, L ;
WANG, APL ;
COULSON, LD .
ANALYTICAL CHEMISTRY, 1993, 65 (04) :493-495
[10]   Ionic-liquid matrices for quantitative analysis by MALDI-TOF mass spectrometry [J].
Li, YL ;
Gross, ML .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2004, 15 (12) :1833-1837