UNSTEADY FLOW ANALYSIS AND EXPERIMENTAL INVESTIGATION OF AXIAL-FLOW PUMP

被引:106
作者
Zhang De-sheng [1 ]
Shi Wei-dong [1 ]
Chen Bin [1 ]
Guan Xing-fan [1 ]
机构
[1] Jiangsu Univ, Tech & Res Ctr Fluid Machinery Engn, Zhenjiang 212013, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
axial-flow pump; unsteady flow; pressure fluctuation; high efficiency; flow field measurement; PERFORMANCE; DESIGN;
D O I
10.1016/S1001-6058(09)60025-1
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The three-dimensional unsteady turbulent flow in axial-flow pumps was simulated based on Navier-Stoke solver embedded with k - epsilon RNG turbulence model and SIMPLEC algorithm. Numerical results show that the unsteady prediction results are more accurate than the steady results, and the maximal error of unsteady prediction is only 4.54%. The time-domain spectrums show that the static pressure fluctuation curves at the inlet and outlet of the rotor and the outlet of the stator are periodic, and all have four peaks and four valleys. The pressure fluctuation amplitude increases from the hub to the tip at the inlet and outlet of the rotor, but decreases at the outlet of the stator. The pressure fluctuation amplitude is the greatest at the inlet of the rotor, and the average amplitude decreases sharply from the inlet to the outlet. The frequency spectrums obtained by Fast Fourier Transform (FFT) show that the dominant frequency is approximately equal to the blade passing frequency. The static pressure on the pressure side of hydrofoil on different stream surfaces remains almost consistent, and increases gradually from the blade inlet to the exit on the suction side at different time steps. The axial velocity distribution is periodic and is affected by the stator blade number at the rotor exit. The experimental results show that the flow is almost axial and the pre-rotation is very small at the rotor inlet under the conditions of 0.8 Q(N) -1.2 Q(N). Due to the clearance leakage, the pressure, circulation and meridional velocity at the rotor outlet all decrease near the hub leakage and tip clearance regions.
引用
收藏
页码:35 / 43
页数:9
相关论文
共 15 条
[1]   SUCTION REVERSE FLOW IN AN AXIAL-FLOW PUMP [J].
ALPAN, K ;
PENG, WW .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1991, 113 (01) :90-97
[2]  
CHEN HX, 2009, CHINESE J HYDRODYNAM, V24, P480
[3]  
Dupont P, 2005, PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER CONFERENCE - 2005, VOL 1, PTS A AND B, P1087
[4]   DESIGN OF IMPLANTABLE AXIAL-FLOW BLOOD PUMP AND NUMERICAL STUDIES ON ITS PERFORMANCE [J].
Fan Hui-min ;
Hong Fang-wen ;
Zhou Lian-di ;
Chen Yin-sheng ;
Ye Liang ;
Liu Zhong-min .
JOURNAL OF HYDRODYNAMICS, 2009, 21 (04) :445-452
[5]   An investigation of the flow and overall performance in a water-jet axial flow pump based on computational fluid dynamics and inverse design method [J].
Gao, H. ;
Lin, W. L. ;
Du, Z. H. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2008, 222 (A5) :517-527
[6]  
Huang Huan-ming, 2009, Journal of Shanghai Jiaotong University, V43, P124
[7]   NUMERICAL INVESTIGATION OF PERFORMANCE OF AN AXIAL-FLOW PUMP WITH INDUCER [J].
Li Yao-jun ;
Wang Fu-jun .
JOURNAL OF HYDRODYNAMICS, 2007, 19 (06) :705-711
[8]  
Shigemitsu T., 2008, Transactions of the Japan Society of Mechanical Engineers, V74, P1091, DOI [10.1299/kikaib.74.1091, DOI 10.1299/KIKAIB.74.1091]
[9]  
SITARAM N, 1981, ASME, V103, P406
[10]  
Wang FJ, 2006, J HYDRODYN, V18, P243