Frequency range selection method of trans-impedance amplifier for high sensitivity lock-in amplifier used in the optical sensors

被引:0
|
作者
Park, Chang-In [1 ]
Jeon, Su-Jin [1 ]
Hong, Nam-Pyo [1 ]
Choi, Young-Wan [1 ]
机构
[1] Chung Ang Univ, Sch Elect & Elect Engn, 221 Heuksuk Dong, Seoul 156756, South Korea
来源
SMART PHOTONIC AND OPTOELECTRONIC INTEGRATED CIRCUITS XVIII | 2016年 / 9751卷
关键词
lock-in amplifier; optical signal modulation frequency; trans-impedance amplifier; noise region; frequency range selection; optical signal detection system;
D O I
10.1117/12.2212415
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Lock-in amplifier (LIA) has been proposed as a detection technique for optical sensors because it can measure low signal in high noise level. LIA uses synchronous method, so the input signal frequency is locked to a reference frequency that is used to carry out the measurements. Generally, input signal frequency of LIA used in optical sensors is determined by modulation frequency of optical signal. It is important to understand the noise characteristics of the trans-impedance amplifier (TIA) to determine the modulation frequency. The TIA has a frequency range in which noise is minimized by the capacitance of photo diode (PD) and the passive component of TIA feedback network. When the modulation frequency is determined in this range, it is possible to design a robust system to noise. In this paper, we propose a method for the determination of optical signal modulation frequency selection by using the noise characteristics of TIA. Frequency response of noise in TIA is measured by spectrum analyzer and minimum noise region is confirmed. The LIA and TIA circuit have been designed as a hybrid circuit. The optical sensor is modeled by the laser diode (LD) and photo diode (PD) and the modulation frequency was used as the input to the signal generator. The experiments were performed to compare the signal to noise ratio (SNR) of the minimum noise region and the others. The results clearly show that the SNR is enhanced in the minimum noise region of TIA.
引用
收藏
页数:6
相关论文
共 47 条
  • [31] High-sensitivity ethylene gas sensor based on NDIR and dual-channel lock-in amplifier
    Zhang, Yunbo
    Jiang, Pai
    Cao, Weijie
    Li, Xiaoping
    Lai, Jianjun
    OPTIK, 2020, 223
  • [32] Low-noise and high-speed trans-impedance amplifier for nanopore sensor (vol 94, 074704, 2023)
    Fang, Shaoxi
    Yin, Bohua
    Xie, Wanyi
    He, Shixuan
    Liang, Liyuan
    Tang, Peng
    Tian, Rong
    Weng, Ting
    Yuan, Jiahu
    Wang, Deqiang
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (12):
  • [33] A 0.8V 40 Gb/s Novel CMOS Regulated Cascode Trans-impedance Amplifier for Optical Sensing Applications
    Hasan, S. M. Rezaul
    JOURNAL OF SIGNAL PROCESSING SYSTEMS FOR SIGNAL IMAGE AND VIDEO TECHNOLOGY, 2013, 72 (01): : 63 - 68
  • [34] A 0.8V 40 Gb/s Novel CMOS Regulated Cascode Trans-impedance Amplifier for Optical Sensing Applications
    S. M. Rezaul Hasan
    Journal of Signal Processing Systems, 2013, 72 : 63 - 68
  • [35] MODIFICATION OF ITHACO MODEL 391A LOCK-IN AMPLIFIER FOR USE IN THE HIGH-DYNAMIC-RANGE MODE AT THE FREQUENCY-RANGE FROM 60 TO 120 KHZ
    MAEDA, S
    SHINDO, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (10): : 3338 - 3339
  • [36] Error estimation and enhanced stiffness sensitivity in contact resonance force microscopy with a multiple arbitrary frequency lock-in amplifier (MAFLIA)
    Flater, Erin E.
    Mugdha, Arya C.
    Gupta, Saurabh
    Hudson, William A.
    Fahrenkamp, Abbigail A.
    Killgore, Jason P.
    Wilson, Jesse W.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2020, 31 (11)
  • [37] Portable Lock-in Amplifier-Based Electrochemical Method to Measure an Array of 64 Sensors for Point-of-Care Applications
    Hrdy, Radim
    Kynclova, Hana
    Klepacova, Ivana
    Bartosik, Martin
    Neuzil, Pavel
    ANALYTICAL CHEMISTRY, 2017, 89 (17) : 8731 - 8737
  • [38] A low-power and high-gain frontend for GHz application using trans-impedance amplifier for fast particle detection
    Kholili, M. J.
    Miyahara, M.
    Shoji, M.
    Kurniawan, E.
    Prakosa, J. A.
    Tanaka, M. M.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (11)
  • [39] Measurement of mutual inductance from the frequency dependence of impedance of AC coupled circuits using a digital dual-phase lock-in amplifier
    Schauber, Michael J.
    Newman, Seth A.
    Goodman, Lindsey R.
    Suzuki, Itsuko S.
    Suzuki, Masatsugu
    AMERICAN JOURNAL OF PHYSICS, 2008, 76 (02) : 129 - 132
  • [40] A portable analog lock-in amplifier for accurate phase measurement and application in high-precision optical oxygen concentration detection
    Xi Chen
    Jun Chang
    Fupeng Wang
    Zongliang Wang
    Wei Wei
    Yuanyuan Liu
    Zengguang Qin
    Photonic Sensors, 2017, 7 : 27 - 36