Comparison of three methods of facial measurement

被引:150
作者
Ghoddousi, H.
Edler, R.
Haers, P.
Wertheim, D.
Greenhill, D.
机构
[1] Guys Hosp, S Thames Cleft Serv, London SE1 9RT, England
[2] Kingston Univ, Fac Comp Informat Syst & Math, Kingston upon Thames KT1 2EE, Surrey, England
关键词
facial anthropometry; photography; stereophotogrammetry;
D O I
10.1016/j.ijom.2006.10.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aims of this study were to assess the accuracy of measurements recorded by 3D stereophotogrammetry and to compare three methods of facial measurement: manual anthropometry, 3D stereophotogrammetry and 2D photography. Measurements were taken from 14 landmarks on each of six volunteers and compared. In addition, the variability of the methods was assessed. Three-dimensional measurements were shown to compare well with manual measurements on volunteers as well as test objects for which the mean difference was 0.23 mm (shortest distance) and 0.13 mm (surface). All the three methods of measurement were found to have good levels of repeatability. Two-dimensional measurements were more variable than manual measurements (P = 0.021). Three-dimensional stereophotogrammetric measurements were shown to compare well with manual measurements although the values obtained were mostly slightly larger. Stereophotogrammetry allows images to be taken in a Medical Photography Department, facilitating the accurate measurement of facial morphology from digitized data, including changes associated with treatment or growth. There are clear potential benefits of using 3D measurements in the assessment of facial deformity.
引用
收藏
页码:250 / 258
页数:9
相关论文
共 32 条
[21]  
Kolar JC., 1997, CRANIOFACIAL ANTHROP
[22]   Reliability of a 3D surface laser scanner for orthodontic applications [J].
Kusnoto, B ;
Evans, CA .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2002, 122 (04) :342-348
[23]  
Lee JY, 2004, ANGLE ORTHOD, V74, P587
[24]   Laser-scan-based navigation in cranio-maxillofacial surgery [J].
Marmulla, R ;
Hassfeld, S ;
Lüth, T ;
Mühling, J .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2003, 31 (05) :267-277
[25]   Digital two-dimensional photogrammetry: A comparison of three techniques of obtaining digital photographs [J].
Nechala, P ;
Mahoney, J ;
Farkas, LG .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 103 (07) :1819-1825
[26]  
RICHTSMEIER JT, 1995, CLEFT PALATE-CRAN J, V32, P217, DOI 10.1597/1545-1569(1995)032<0217:PRAVOT>2.3.CO
[27]  
2
[28]   Short-term variability and sampling distribution of various parameters of urinary albumin excretion in patients with non-insulin-dependent diabetes mellitus [J].
Smulders, YM ;
Slaats, EH ;
Rakic, M ;
Smulders, FTY ;
Stehouwer, CDA ;
Silberbusch, J .
JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1998, 132 (01) :39-46
[29]  
WARD RE, 1991, J CRAN GENET DEV BIO, V11, P156
[30]   Digital three-dimensional photogrammetry: Evaluation of anthropometric precision and accuracy using a Genex 3D camera system [J].
Weinberg, SM ;
Scott, NM ;
Neiswanger, K ;
Brandon, CA ;
Marazita, ML .
CLEFT PALATE-CRANIOFACIAL JOURNAL, 2004, 41 (05) :507-518