Localization ability with bimodal hearing aids and bilateral cochlear implants

被引:106
作者
Seeber, BU
Baumann, U
Fastl, H
机构
[1] Tech Univ Munich, MMK, AG Tech Akust, D-80333 Munich, Germany
[2] Univ Munich, Dept Expt Audiol, D-81377 Munich, Germany
关键词
D O I
10.1121/1.1776192
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
After successful cochlear implantation in one ear, some patients continue to use a hearing aid at the contralateral ear. They report an improved reception of speech, especially in noise, as well as a better perception of music when the hearing aid and cochlear implant are used in this bimodal combination. Some individuals in this bimodal patient group also report the impression of an improved localization ability. Similar experiences are reported by the group of bilateral cochlear implantees. In this study, a survey of 11 bimodally and 4 bilaterally equipped cochlear implant users was carried out to assess localization ability. Individuals in the bimodal implant group were all provided with the same type of hearing aid in the opposite ear, and subjects in the bilateral implant group used cochlear implants of the same manufacturer on each ear. Subjects adjusted the spot of a computer-controlled laser-pointer to the perceived direction of sound incidence in the frontal horizontal plane by rotating a trackball. Two subjects of the bimodal group who had substantial residual hearing showed localization ability in the bimodal configuration, whereas using each single device only the subject with better residual hearing was able to discriminate the side of sound origin. Five other subjects with more pronounced hearing loss displayed an ability for side discrimination through the use of bimodal aids, while four of them were already able to discriminate the side with a single device. Of the bilateral cochlear implant group one subject showed localization accuracy close to that of normal hearing subjects. This subject was also able to discriminate the side of sound origin using the first implanted device alone. The other three bilaterally equipped subjects showed limited localization ability using both devices. Among them one subject demonstrated a side-discrimination ability using only the first implanted device. (C) 2004 Acoustical Society of America.
引用
收藏
页码:1698 / 1709
页数:12
相关论文
共 38 条
[1]  
BAUMANN U, 2001, FORTSCHRITTE AKUSTIK
[2]  
Blauert J., 1996, SPATIAL HEARING PSYC, DOI [https://doi.org/10.7551/mitpress/6391.001.0001, DOI 10.7551/MITPRESS/6391.001.0001, 10.7551/mitpress/6391.001.0001]
[3]   Gap detection by early-deafened cochlear-implant subjects [J].
Busby, PA ;
Clark, GM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 105 (03) :1841-1852
[4]  
DOOLEY GJ, 1993, ARCH OTOLARYNGOL, V119, P55
[5]  
DURLACH NI, 1981, AUDIOLOGY, V20, P181
[6]  
FEDDERSEN UE, 1957, J ACOUST SOC AM, V29, P988
[7]   Binaural cochlear implants placed during the same operation [J].
Gantz, BJ ;
Tyler, TS ;
Rubinstein, JT ;
Wolaver, A ;
Lowder, M ;
Abbas, T ;
Brown, T ;
Hughes, M ;
Preece, JP .
OTOLOGY & NEUROTOLOGY, 2002, 23 (02) :169-180
[8]   Abnormal auditory experience induces frequency-specific adjustments in unit tuning for binaural localization cues in the optic tectum of juvenile owls [J].
Gold, JI ;
Knudsen, EI .
JOURNAL OF NEUROSCIENCE, 2000, 20 (02) :862-877
[9]  
Grantham D. Wesley, 1995, P297, DOI 10.1016/B978-012505626-7/50011-X
[10]  
GRAY RF, 1993, ADV OTO-RHINO-LARYNG, V48, P174