Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectral prediction of postmortem interval from vitreous humor samples

被引:23
|
作者
Zhang, Ji [1 ]
Wei, Xin [2 ]
Huang, Jiao [3 ]
Lin, Hancheng [2 ]
Deng, Kaifei [1 ]
Li, Zhengdong [1 ]
Shao, Yu [1 ]
Zou, Donghua [1 ]
Chen, Yijiu [1 ]
Huang, Ping [1 ]
Wang, Zhenyuan [1 ,2 ]
机构
[1] Shanghai Forens Serv Platform, Acad Forens Sci, Shanghai Key Lab Forens Med, Minist Justice, Shanghai 200063, Peoples R China
[2] Xi An Jiao Tong Univ, Dept Forens Pathol, Xian 710061, Shaanxi, Peoples R China
[3] Xuzhou Med Univ, Dept Forens Med, Xuzhou 221000, Jiangsu, Peoples R China
基金
美国国家科学基金会;
关键词
Forensic medicine; Postmortem interval; Fourier transform infrared spectroscopy; Machine learning; Vitreous humor; ARTIFICIAL NEURAL-NETWORKS; IR SPECTROSCOPY; LEAST-SQUARES; DIAGNOSIS; BLOOD; DEGRADATION; PLASMA; SERUM; DEATH; TIME;
D O I
10.1007/s00216-018-1367-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Evaluation of postmortem interval (PMI) is of paramount importance to guide criminal investigations, especially when witnesses are not found. However, accurate PMI estimation is a challenging task in the forensic community due to the limitations of existing methods. The study aims to investigate the potential of attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy for predicting PMI based on vitreous humor (VH). VH samples were collected from 72 rabbits in the range of 0-48h postmortem at a 6-h interval. Their FTIR spectra were normalized by the extended multiplicative signal correction (RMSC) and divided into calibration and validation sets. After analysis of the absorption bands, the Bayesian ridge regression (BRR), support vector regression (SVR), and artificial neural network (ANN) methods were established by the calibration set using a 10-fold cross-validation that was further used to predict the PMI in the validation set. The validity of the models was assessed by a permutation test. The current study demonstrated that multiple macromolecules in the VH samples were reflected in a FTIR spectrum, and the spectral absorption bands at 1313 and 925cm(-1) were highly correlated with PMI. The three models allowed generalization to the validation set due to similar R-2 and errors between the calibration and validation tests. The highest accuracy with R-2=0.983 and error=2.018h was achieved by the ANN model in the validation test. The results suggest that ATR-FTIR spectroscopy may be useful for VH analysis in order to predict PMI in the future.
引用
收藏
页码:7611 / 7620
页数:10
相关论文
共 50 条
  • [41] Rapid and Nondestructive Forensic Identification of Tire Particles by Attenuated Total Reflectance - Fourier Transform Infrared Spectroscopy and Chemometrics
    He, Xinlong
    Wang, Jifen
    ANALYTICAL LETTERS, 2020, 53 (05) : 714 - 734
  • [42] Spectral Mining for Discriminating Blood Origins in the Presence of Substrate Interference via Attenuated Total Reflection Fourier Transform Infrared Spectroscopy: Postmortem or Antemortem Blood?
    Takamura, Ayari
    Watanabe, Ken
    Akutsu, Tomoko
    Ikegaya, Hiroshi
    Ozawa, Takeaki
    ANALYTICAL CHEMISTRY, 2017, 89 (18) : 9797 - 9804
  • [43] Forensic Hair Differentiation Using Attenuated Total Reflection Fourier Transform Infrared (ATR FT-IR) Spectroscopy
    Manheim, Jeremy
    Doty, Kyle C.
    McLaughlin, Gregory
    Lednev, Igor K.
    APPLIED SPECTROSCOPY, 2016, 70 (07) : 1109 - 1117
  • [44] Monitoring the thermal gelation of cellulose ethers in situ using attenuated total reflectance Fourier transform infrared spectroscopy
    Banks, SR
    Sammon, C
    Melia, CD
    Timmins, P
    APPLIED SPECTROSCOPY, 2005, 59 (04) : 452 - 459
  • [45] Application of Linear Discriminant Analysis and Attenuated Total Reflectance Fourier Transform Infrared Microspectroscopy for Diagnosis of Colon Cancer
    Khanmohammadi, Mohammadreza
    Garmarudi, Amir Bagheri
    Samani, Simin
    Ghasemi, Keyvan
    Ashuri, Ahmad
    PATHOLOGY & ONCOLOGY RESEARCH, 2011, 17 (02) : 435 - 441
  • [46] Determination of Cellulose, Water, and N-Methylmorpholine N-Oxide during the Production of Lyocell by Attenuated Total Reflection (ATR) - Fourier Transform Infrared (FTIR) Spectroscopy
    Luo, Xuebing
    Yuan, Hongfu
    Song, Chunfeng
    Meng, Yan
    Li, Xiaoyu
    ANALYTICAL LETTERS, 2022, 55 (03) : 388 - 398
  • [47] Feasibility study for the detection of Trichinella spiralis in a murine model using mid-Fourier transform infrared spectroscopy (MID-FTIR) with attenuated total reflectance (ATR) and soft independent modelling of class analogies (SIMCA)
    Gomez-de Anda, Fabian
    Gallardo-Velazquez, Tzayhri
    Osorio-Revilla, Guillermo
    Dorantes-Alvarez, Lidia
    Calderon-Dominguez, Georgina
    Nogueda-Torres, Benjamin
    de-la-Rosa-Arana, Jorge-Luis
    VETERINARY PARASITOLOGY, 2012, 190 (3-4) : 496 - 503
  • [48] Analysis of platelets in hypertensive and normotensive individuals using Raman and Fourier transform infrared-attenuated total reflectance spectroscopies
    Garcia-Rubio, Diana L.
    de la Mora, M. B.
    Badillo-Ramirez, Isidro
    Cerecedo, Doris
    Saniger, Jose M.
    Luis Benitez-Benitez, Jose
    Villagran-Muniz, M.
    JOURNAL OF RAMAN SPECTROSCOPY, 2019, 50 (04) : 509 - 521
  • [49] In situ attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy combined with non-negative matrix factorization for investigating the synthesis reaction mechanism of 3-amino-4-amino-oxime furazan
    Zhang, Tianlong
    He, Ting
    Yan, Chunhua
    Gao, Xinyu
    Ma, Junxiu
    Li, Hua
    ANALYTICAL METHODS, 2018, 10 (48) : 5817 - 5822
  • [50] Attenuated Total Reflection Fourier Transform Infrared (ATR FT-IR) Spectroscopy Sensitivity to the Thermal Decay of Bone Collagen
    Thomas, Brian
    Anderson, Kevin
    De Silva, Imesha
    Verbeck, Guido
    Taylor, Stephen
    APPLIED SPECTROSCOPY, 2023, 77 (01) : 53 - 61