Capillary batch injection analysis: a novel approach for analyzing nanoliter samples

被引:11
作者
Backofen, U
Hoffmann, W
Matysik, FM [1 ]
机构
[1] Forschungszentrum Karlsruhe, Inst Instrumentelle Analyt, D-76021 Karlsruhe, Germany
[2] Univ Leipzig, Inst Analyt Chem, D-04103 Leipzig, Germany
关键词
capillary batch injection; miniaturization; amperometric detection; square-wave voltammetry; microelectrode; wall-tube electrode;
D O I
10.1016/S0003-2670(98)00036-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A significantly miniaturized version of batch injection analysis (BIA) is described. The new technique is based on solution handling by means of a piece of fused silica capillary and is, therefore, termed as capillary batch injection analysis (CBIA). The operation of CBIA is characterized by dispensing nanoliter samples onto the surface of a micro- or minidisk electrode which is immersed in a 1 ml blank solution. The effects of various parameters such as injection volume, capillary outlet/electrode distance, dispensing rate, presence or absence of stirring and capillary/electrode dimensions on the CBIA response are studied and optimized conditions for CBIA operation are derived. Repetitive injections of 188 nl aliquots of hexacyanoferrate(II) are performed with an injection rate of 600 samples/h, with a good precision of the signal height expressed by a relative standard deviation of 1.1% (n=31). Furthermore, CBIA measurements are combined with square-wave voltammetry by recording complete voltammograms during the injection of sub-mu l samples. The enhancement of selectivity is demonstrated by the simultaneous determination of ferrocene and ferrocenemonocarboxylic acid at concentrations ranging from 2.5 x 10(-5) M to 2.5 x 10(-4) M. The square-wave voltammograms of CBIA are nearly identical to those obtained in a large-volume batch experiment. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:213 / 220
页数:8
相关论文
共 17 条
  • [1] Brett C. M. A., 1993, ELECTROCHEMISTRY, P151
  • [2] AMPEROMETRIC AND VOLTAMMETRIC DETECTION IN BATCH INJECTION-ANALYSIS
    BRETT, CMA
    BRETT, AMO
    MITOSERIU, LC
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (19) : 3145 - 3150
  • [3] EFFECTS OF CELL DESIGN ON ELECTROCHEMICAL MEASUREMENTS IN SUBMICROLITER VOLUMES
    CLARK, ME
    INGRAM, JL
    BLAKELY, EE
    BOWYER, WJ
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 385 (02): : 157 - 162
  • [4] Electrochemical analysis in picoliter microvials
    Clark, RA
    Hietpas, PB
    Ewing, AG
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (02) : 259 - 263
  • [5] MULTICOMPONENT BATCH-INJECTION ANALYSIS USING AN ARRAY OF ION-SELECTIVE ELECTRODES
    DIAMOND, D
    LU, JM
    CHEN, Q
    WANG, J
    [J]. ANALYTICA CHIMICA ACTA, 1993, 281 (03) : 629 - 635
  • [6] ELECTROCHEMICAL DETECTION IN MICROCOLUMN SEPARATIONS
    EWING, AG
    MESAROS, JM
    GAVIN, PF
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (09) : A527 - A537
  • [7] Grossman P.D., 1992, CAPILLARY ELECTROPHO
  • [8] Development and operating characteristics of micro flow injection analysis systems based on electroosmotic flow - A review
    Haswell, SJ
    [J]. ANALYST, 1997, 122 (01) : R1 - R10
  • [9] CAPILLARY ZONE ELECTROPHORESIS
    JORGENSON, JW
    LUKACS, KD
    [J]. SCIENCE, 1983, 222 (4621) : 266 - 272
  • [10] ELECTROOSMOTICALLY PUMPED CAPILLARY FLOW-INJECTION ANALYSIS - VALVE-BASED INJECTION SYSTEMS AND SAMPLE THROUGHPUT
    LIU, SR
    DASGUPTA, PK
    [J]. ANALYTICA CHIMICA ACTA, 1993, 283 (02) : 739 - 745