Of dipolar dc excitation and dc tomography in the rf quadrupole ion trap

被引:21
作者
Plass, WR [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
translational excitation; ion tomography; quadrupole ion trap; Mathieu equation; simulation;
D O I
10.1016/S1387-3806(00)00241-4
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A theory of dipolar dc excitation and dc tomography in the rf quadrupole ion trap is presented. The equation of motion for ions subject to a dipolar dc field is written in the form of a Mathieu equation with time indcpendcnt inhomogeneity and solved analytically. Three cases are considcred explicitly: application of continuous dipolar dc fields, application of dipolar pulses for translational excitation of ion motion, and application of dipolar pulses for selective ejection of ions. The effect of monopolar pulses and nonlinear fields is investigated by simulations of ion motion. It is shown that translational excitation of ions by dipolar dc pulses has a near linear response of oscillation amplitudc to the voltage of the dipolar dc pulse and is nearly mass indcpendcnt for a large mass range, providcd the pulse width is chosen appropriately. Formulae are given for optimum choice of pulse voltage and width. Dc tomography, a technique which probes ion motion by selective ejection of ions due to the application of short dipolar dc pulses, is shown to be a feasible method for monitoring the secular oscillation of a coherent group of ions, sensitive to even small changes in ion position. (Int J Mass Spectrom 202 (2000) 175-197) (C) 2000 Elsevier Science B.V.
引用
收藏
页码:175 / 197
页数:23
相关论文
共 66 条
[1]  
[Anonymous], CLASSICAL ELECTRODYN
[2]  
Badman ER, 1999, J MASS SPECTROM, V34, P889, DOI 10.1002/(SICI)1096-9888(199908)34:8<889::AID-JMS848>3.0.CO
[3]  
2-C
[4]   CALCULATED ELECTROSTATIC PROPERTIES OF ION TRAPS [J].
BEATY, EC .
PHYSICAL REVIEW A, 1986, 33 (06) :3645-3656
[5]  
BILLEN JH, 1993, PROCEEDINGS OF THE 1993 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, P790, DOI 10.1109/PAC.1993.308773
[6]  
Bonner R. F., 1972, International Journal of Mass Spectrometry and Ion Physics, V10, P197, DOI 10.1016/0020-7381(72)83008-0
[7]  
Bui HA, 1998, J MASS SPECTROM, V33, P297, DOI 10.1002/(SICI)1096-9888(199804)33:4<297::AID-JMS665>3.3.CO
[8]  
2-M
[9]   Probing radial and axial secular frequencies in a quadrupole ion trap [J].
Carette, M ;
Perrier, P ;
Zerega, Y ;
Brincourt, G ;
Payan, JC ;
Andre, J .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1997, 171 (1-3) :253-261
[10]   Radial distributions and ejection times of molecular ions in an ion trap mass spectrometer: A laser tomography study of effects of ion density and molecular type [J].
Cleven, CD ;
Cooks, RG ;
Garrett, AW ;
Nogar, NS ;
Hemberger, PH .
JOURNAL OF PHYSICAL CHEMISTRY, 1996, 100 (01) :40-46