Fully-automatic left ventricular segmentation from long-axis cardiac cine MR scans

被引:20
|
作者
Shahzad, Rahil [1 ]
Tao, Qian [1 ]
Dzyubachyk, Oleh [1 ]
Staring, Marius [1 ]
Lelieveldt, Boudewijn P. F. [1 ,2 ]
van der Geest, Rob J. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, Div Image Proc, POB 9600, NL-2300 RC Leiden, Netherlands
[2] Delft Univ Technol, Intelligent Syst Dept, POB 5031, NL-2600 GA Delft, Netherlands
关键词
Atlas-based segmentation; Registration; Cardiac MRI; Left ventricular segmentation; Long-axis cine MRI; CARDIOVASCULAR MAGNETIC-RESONANCE; EJECTION FRACTION; QUANTIFICATION; DISEASE; MODELS; IMAGES; VOLUME; MASS;
D O I
10.1016/j.media.2017.04.004
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
With an increasing number of large-scale population-based cardiac magnetic resonance (CMR) imaging studies being conducted nowadays, there comes the mammoth task of image annotation and image analysis. Such population-based studies would greatly benefit from automated pipelines, with an efficient CMR image analysis workflow. The purpose of this work is to investigate the feasibility of using a fully-automatic pipeline to segment the left ventricular endocardium and epicardium simultaneously on two orthogonal (vertical and horizontal) long-axis cardiac cine MRI scans. The pipeline is based on a multi-atlas-based segmentation approach and a spatio-temporal registration approach. The performance of the method was assessed by: (i) comparing the automatic segmentations to those obtained manually at both the end-diastolic and end-systolic phase, (ii) comparing the automatically obtained clinical parameters, including end-diastolic volume, end-systolic volume, stroke volume and ejection fraction, with those defined manually and (iii) by the accuracy of classifying subjects to the appropriate risk category based on the estimated ejection fraction. Automatic segmentation of the left ventricular endocardium was achieved with a Dice similarity coefficient (DSC) of 0.93 on the end-diastolic phase for both the vertical and horizontal long-axis scan; on the end-systolic phase the DSC was 0.88 and 0.85, respectively. For the epicardium, a DSC of 0.94 and 0.95 was obtained on the end-diastolic vertical and horizontal long-axis scans; on the end-systolic phase the DSC was 0.90 and 0.88, respectively. With respect to the clinical volumetric parameters, Pearson correlation coefficient (R) of 0.97 was obtained for the end-diastolic volume, 0.95 for end-systolic volume, 0.87 for stroke volume and 0.84 for ejection fraction. Risk category classification based on ejection fraction showed that 80% of the subjects were assigned to the correct risk category and only one subject (< 1%) was more than one risk category off. We conclude that the proposed automatic pipeline presents a viable and cost-effective alternative for manual annotation. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:44 / 55
页数:12
相关论文
共 50 条
  • [41] An SPCNN-GVF-based approach for the automatic segmentation of left ventricle in cardiac cine MR images
    Ma, Yurun
    Wang, Li
    Ma, Yide
    Dong, Min
    Du, Shiqiang
    Sun, Xiaoguang
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (11) : 1951 - 1964
  • [42] An SPCNN-GVF-based approach for the automatic segmentation of left ventricle in cardiac cine MR images
    Yurun Ma
    Li Wang
    Yide Ma
    Min Dong
    Shiqiang Du
    Xiaoguang Sun
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 1951 - 1964
  • [43] Parameter optimization for filtering and segmentation of left ventricular long-axis SPAMM tagged magnetic resonance images
    Chai, Jyh-Wen
    Fu, Ja-Chih
    Chen, Clayton C. C.
    Zeng, Jun-Hua
    Chen, Shin-Hong
    Huang, Jheng-Jhe
    JOURNAL OF INDUSTRIAL AND PRODUCTION ENGINEERING, 2015, 32 (05) : 340 - 350
  • [44] Automatic computation of left ventricular ejection fraction from spatiotemporal information in cine-SSFP cardiac MR images
    Pednekar, Amol S.
    Muthupillai, Raja
    Cheong, Benjamin
    Flamm, Scott D.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (01) : 39 - 50
  • [45] An iterative multi-path fully convolutional neural network for automatic cardiac segmentation in cine MR images
    Ma, Zongqing
    Wu, Xi
    Wang, Xin
    Song, Qi
    Yin, Youbing
    Cao, Kunlin
    Wang, Yan
    Zhou, Jiliu
    MEDICAL PHYSICS, 2019, 46 (12) : 5652 - 5665
  • [46] Right ventricular long-axis function in relation to left ventricular systolic function
    Emilsson, K
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2004, 24 (04) : 212 - 215
  • [47] Automatic Segmentation and Disease Classification Using Cardiac Cine MR Images
    Wolterink, Jelmer M.
    Leiner, Tim
    Viergever, Max A.
    Isgum, Ivana
    STATISTICAL ATLASES AND COMPUTATIONAL MODELS OF THE HEART: ACDC AND MMWHS CHALLENGES, 2018, 10663 : 101 - 110
  • [48] Computational Platform Based on Deep Learning for Segmenting Ventricular Endocardium in Long-axis Cardiac MR Imaging
    Leng, Shuang
    Yang, Xulei
    Zhao, Xiaodan
    Zeng, Zeng
    Su, Yi
    Koh, Angela S.
    Sim, David
    Tan, Ju Le
    Tan, Ru San
    Zhong, Liang
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 4500 - 4503
  • [49] Localization and Segmentation of Left Ventricle in Cardiac Cine-MR Images
    Kurkure, Uday
    Pednekar, Amol
    Muthpillai, Raja
    Flamm, Scott D.
    Kakadiaris, Ioannis A.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (05) : 1360 - 1370
  • [50] Left ventricular mass:: Manual and automatic segmentation of true FISP and FLASH cine MR images in dogs and pigs
    François, CJ
    Fieno, DS
    Shors, SM
    Finn, JP
    RADIOLOGY, 2004, 230 (02) : 389 - 395