Fully-automatic left ventricular segmentation from long-axis cardiac cine MR scans

被引:20
作者
Shahzad, Rahil [1 ]
Tao, Qian [1 ]
Dzyubachyk, Oleh [1 ]
Staring, Marius [1 ]
Lelieveldt, Boudewijn P. F. [1 ,2 ]
van der Geest, Rob J. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, Div Image Proc, POB 9600, NL-2300 RC Leiden, Netherlands
[2] Delft Univ Technol, Intelligent Syst Dept, POB 5031, NL-2600 GA Delft, Netherlands
关键词
Atlas-based segmentation; Registration; Cardiac MRI; Left ventricular segmentation; Long-axis cine MRI; CARDIOVASCULAR MAGNETIC-RESONANCE; EJECTION FRACTION; QUANTIFICATION; DISEASE; MODELS; IMAGES; VOLUME; MASS;
D O I
10.1016/j.media.2017.04.004
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
With an increasing number of large-scale population-based cardiac magnetic resonance (CMR) imaging studies being conducted nowadays, there comes the mammoth task of image annotation and image analysis. Such population-based studies would greatly benefit from automated pipelines, with an efficient CMR image analysis workflow. The purpose of this work is to investigate the feasibility of using a fully-automatic pipeline to segment the left ventricular endocardium and epicardium simultaneously on two orthogonal (vertical and horizontal) long-axis cardiac cine MRI scans. The pipeline is based on a multi-atlas-based segmentation approach and a spatio-temporal registration approach. The performance of the method was assessed by: (i) comparing the automatic segmentations to those obtained manually at both the end-diastolic and end-systolic phase, (ii) comparing the automatically obtained clinical parameters, including end-diastolic volume, end-systolic volume, stroke volume and ejection fraction, with those defined manually and (iii) by the accuracy of classifying subjects to the appropriate risk category based on the estimated ejection fraction. Automatic segmentation of the left ventricular endocardium was achieved with a Dice similarity coefficient (DSC) of 0.93 on the end-diastolic phase for both the vertical and horizontal long-axis scan; on the end-systolic phase the DSC was 0.88 and 0.85, respectively. For the epicardium, a DSC of 0.94 and 0.95 was obtained on the end-diastolic vertical and horizontal long-axis scans; on the end-systolic phase the DSC was 0.90 and 0.88, respectively. With respect to the clinical volumetric parameters, Pearson correlation coefficient (R) of 0.97 was obtained for the end-diastolic volume, 0.95 for end-systolic volume, 0.87 for stroke volume and 0.84 for ejection fraction. Risk category classification based on ejection fraction showed that 80% of the subjects were assigned to the correct risk category and only one subject (< 1%) was more than one risk category off. We conclude that the proposed automatic pipeline presents a viable and cost-effective alternative for manual annotation. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:44 / 55
页数:12
相关论文
共 45 条
  • [1] Assessment of ventricular function and mass by cardiac magnetic resonance imaging
    Alfakih, K
    Reid, S
    Jones, T
    Sivananthan, M
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (10) : 1813 - 1822
  • [2] Multi-atlas based segmentation of brain images: Atlas selection and its effect on accuracy
    Aljabar, P.
    Heckemann, R. A.
    Hammers, A.
    Hajnal, J. V.
    Rueckert, D.
    [J]. NEUROIMAGE, 2009, 46 (03) : 726 - 738
  • [3] [Anonymous], 2011, WHO I Global atlas on cardiovascular disease prevention and control
  • [4] [Anonymous], HDB BIOMEDICAL IMAGE
  • [5] Whole-Body MR Imaging in the German National Cohort:Rationale, Design, and Technical Background
    Bamberg, Fabian
    Kauczor, Hans-Ulrich
    Weckbach, Sabine
    Schlett, Christopher L.
    Forsting, Michael
    Ladd, Susanne C.
    Greiser, Karin Halina
    Weber, Marc-Andre
    Schulz-Menger, Jeanette
    Niendorf, Thoralf
    Pischon, Tobias
    Caspers, Svenja
    Amunts, Katrin
    Berger, Klaus
    Buelow, Robin
    Hosten, Norbert
    Hegenscheid, Katrin
    Kroencke, Thomas
    Linseisen, Jakob
    Guenther, Matthias
    Hirsch, Jochen G.
    Koehn, Alexander
    Hendel, Thomas
    Wichmann, Heinz-Erich
    Schmidt, Boege
    Joeckel, Karl-Heinz
    Hoffmann, Wolfgang
    Kaaks, Rudolf
    Reiser, Maximilian F.
    Voelzke, Henry
    [J]. RADIOLOGY, 2015, 277 (01) : 206 - 220
  • [6] Multi-ethnic study of atherosclerosis: Objectives and design
    Bild, DE
    Bluemke, DA
    Burke, GL
    Detrano, R
    Roux, AVD
    Folsom, AR
    Greenland, P
    Jacobs, DR
    Kronmal, R
    Liu, K
    Nelson, JC
    O'Leary, D
    Saad, MF
    Shea, S
    Szklo, M
    Tracy, RP
    [J]. AMERICAN JOURNAL OF EPIDEMIOLOGY, 2002, 156 (09) : 871 - 881
  • [7] Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricle
    Bloomer, TN
    Plein, S
    Radjenovic, A
    Higgins, DM
    Jones, TR
    Ridgway, JP
    Sivananthan, MU
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (06) : 685 - 692
  • [8] Cardiovascular Disease in the Developing World
    Celermajer, David S.
    Chow, Clara K.
    Marijon, Eloi
    Anstey, Nicholas M.
    Woo, Kam S.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (14) : 1207 - 1216
  • [9] Comparison of long and short axis quantification of left ventricular volume parameters by cardiovascular magnetic resonance, with ex-vivo validation
    Childs, Helene
    Ma, Lucia
    Ma, Michael
    Clarke, James
    Cocker, Myra
    Green, Jordin
    Strohm, Oliver
    Friedrich, Matthias G.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2011, 13
  • [10] Dijkstra EW., 1959, NUMER MATH, V1, P269, DOI 10.1007/BF01386390