Comparison of the cobas Human Immunodeficiency Virus 1 (HIV-1) Test Using the cobas 4800 System With COBAS AmpliPrep/COBAS TaqMan HIV-1 Test and Abbott RealTime HIV-1 Assay and Performance Evaluation of cobas HIV-1

被引:2
|
作者
Shin, Kyung-Hwa [1 ,2 ]
Lee, Hyun-Ji [3 ]
Lee, Jin Hyeon [1 ,2 ]
Chang, Chulhun L. [3 ]
Kim, Hyung-Hoi [1 ,2 ,4 ]
机构
[1] Pusan Natl Univ Hosp, Dept Lab Med, Busan, South Korea
[2] Pusan Natl Univ Hosp, Biomed Res Inst, Busan, South Korea
[3] Pusan Natl Univ, Dept Lab Med, Yangsan Hosp, Yangsan, South Korea
[4] Pusan Natl Univ, Lab Med & BioMed Informat Unit, Sch Med, Busan, South Korea
关键词
Human immunodeficiency virus; RNA quantification; Correlation analysis; VIRAL LOAD; GENETIC DIVERSITY; QUANTIFICATION; PLASMA;
D O I
10.1093/ajcp/aqz075
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Objectives: To compare quantified human immunodeficiency virus type 1 (HIV-1) viral load quantified using the cobas HIV-1 test with that obtained using the CAP/CTM HIV-1 and Abbott RealTime HIV-1 tests and evaluate the performance of cobas HIV-1 using the cobas 4800 system. Methods: Clinical samples (n = 123) were quantitatively analyzed using the CAP/CTM HIV-1, Abbott RealTime HIV-1, and cobas HIV-1 tests, and the precision, linearity, and limit of detection of the cobas HIV-1 test were evaluated. Results: Comparable results were obtained by both methods: ([log CAP/CTM HIV-1 value] = 0.979 * [log cobas HIV-1 test value] + 0.034) and ([log Abbott RealTime HIV-1 value] = 0.985 * [log cobas HIV-1 test value] + 0.027). cobas HIV-1 test results for 89.4% and 93.5% were within 0.5 log(10) IU/mL of the CAP/CTM HIV-1 and Abbott RealTime HIV-1 results, respectively. Conclusions: The cobas HIV-1 test showed good performance, and its results correlated well with those of other two tests.
引用
收藏
页码:558 / 562
页数:5
相关论文
共 50 条
  • [1] Comparison of Abbott RealTime HIV-1 and Roche COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 Assays
    Abravaya, K.
    Hackett, J.
    Swanson, P.
    Huang, S.
    Tang, N.
    Robinson, J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2008, 10 (06): : 587 - 587
  • [2] Workflow and cost comparison of COBAS AmpliPrep/COBAS TaqMan HIV-1 test and Abbott ReaITime HIV-1 assay
    Sloma, C. R.
    Gerads, T. M.
    Germer, J. J.
    Mitchell, P. S.
    Yao, J. D.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2007, 9 (05): : 674 - 675
  • [3] Comparison of the Abbott RealTime Human Immunodeficiency Virus Type 1 (HIV-1) Assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test: Workflow, Reliability, and Direct Costs
    Sloma, Cari R.
    Germer, Jeffrey J.
    Gerads, Tara M.
    Mandrekar, Jayawant N.
    Mitchell, P. Shawn
    Yao, Joseph D. C.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (04) : 889 - 895
  • [4] Results of the Abbott RealTime HIV-1 Assay for Specimens Yielding "Target Not Detected" Results by the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test
    Babady, N. Esther
    Germer, Jeffrey J.
    Yao, Joseph D. C.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (03) : 969 - 971
  • [5] Comparative Evaluation of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Version 2 Test Using the TaqMan 48 Analyzer and the Abbott RealTime HIV-1 Assay
    van Rensburg, Estrelita Janse
    Tait, Karen
    Watt, Alistair
    Schall, Robert
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (01) : 377 - 379
  • [6] The performance of the COBAS AmpliPrep/COBAS TaqMan HIV-1 test on the COBAS TaqMan Analyzer and COBAS TaqMan 48 Analyzer
    Ferreira-Gonzalez, A.
    Wilk, M.
    Kretz, A.
    Lazaro, L.
    Epp, L.
    Sabato, M.
    Kingsland, K.
    Loo, P.
    Colaninno, P.
    Engler, H.
    Mills, R.
    Taylor, K.
    Young, S.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2006, 8 (05): : 650 - 650
  • [7] Performance and Evaluation of the COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 Test, Version 2.0
    Schutzbank, T. E.
    Light, A.
    Palmero, M.
    Blanford, C.
    Michel-Treil, V.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2009, 11 (06): : 634 - 634
  • [8] COMPARISON OF THE APTIMA HIV-1 QUANT ASSAY TO THE COBAS AMPLIPREP/COBAS TAQMAN HIV-1 TEST, V2.0
    Hatzakis, A.
    Papachristou, H.
    Kantzanou, M.
    SEXUALLY TRANSMITTED INFECTIONS, 2013, 89 : A353 - A353
  • [9] Evaluation of an Upgraded Version of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Test for HIV-1 Load Quantification
    Damond, F.
    Avettand-Fenoel, V.
    Collin, G.
    Roquebert, B.
    Plantier, J. C.
    Ganon, A.
    Sizmann, D.
    Babiel, R.
    Glaubitz, J.
    Chaix, M. L.
    Brun-Vezinet, F.
    Descamps, D.
    Rouzioux, C.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (04) : 1413 - 1416
  • [10] Evaluation of the Abbott m2000 RealTime Human Immunodeficiency Virus Type 1 (HIV-1) Assay for HIV Load Monitoring in South Africa Compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 Assays
    Scott, Lesley E.
    Noble, Lara D.
    Moloi, Jackie
    Erasmus, Linda
    Venter, Willem D. F.
    Stevens, Wendy
    JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (07) : 2209 - 2217