The Electromagnetic Calorimeter of CMS, Summary and Status

被引:1
作者
Lustermann, Werner [1 ]
机构
[1] ETH, Inst Particle Phys, ETH Honggerberg, CH-8093 Zurich, Switzerland
来源
XIII INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS | 2009年 / 160卷
关键词
DETECTOR;
D O I
10.1088/1742-6596/160/1/012044
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
The construction of the lead tungstate crystal calorimeter for the CMS experiment at the Large Hadron Collider (LHC) is close to completion. The barrel part of the calorimeter composed of 61200 crystals is installed and operated inside CMS. Only 102 readout channels are problematic including the 21 entirely dead, corresponding to 0.17 % and 0.034 %, respectively. All 14648 end-cap crystals axe mounted. The electronics installation and commissioning of one end-cap has finished and the second will be finished in few weeks. The construction of the pre-shower detectors installed in front of the end-caps is well advanced. The many challenges of the design and construction imposed by a 4 Tesla magnetic field, radiation levels ranging from 100 krad up to several Mrad and a bunch crossing rate of 40 MHz were mastered by a huge effort in developing and testing appropriate crystals, photo-detectors and readout electronics carried out over the past similar to 15 years. Test beam results demonstrate that the energy resolution obtained is better than 0.5 % at high energies. All readout channels in the barrel are inter-calibrated to better than 2 % using cosmic muons.
引用
收藏
页数:8
相关论文
共 18 条
[1]   Energy resolution of the barrel of the CMS Electromagnetic Calorimeter [J].
Adzic, P. ;
Alemany-Fernandez, R. ;
Almeida, C. B. ;
Almeida, N. M. ;
Anagnostou, G. ;
Anfreville, M. G. ;
Anicin, I. ;
Antunovic, Z. ;
Auffray, E. ;
Baccaro, S. ;
Baffioni, S. ;
Baillon, P. ;
Barney, D. ;
Barone, L. M. ;
Barrillon, P. ;
Bartoloni, A. ;
Beauceron, S. ;
Beaudette, F. ;
Bell, K. W. ;
Benetta, R. ;
Bercher, M. J. ;
Berthon, U. ;
Betev, B. ;
Beuselinck, R. ;
Bhardwaj, A. ;
Bialas, W. ;
Biino, C. ;
Bimbot, S. ;
Blaha, J. ;
Bloch, P. ;
Blyth, S. ;
Bordalo, P. ;
Bornheim, A. ;
Bourotte, J. M. ;
Britton, D. ;
Brown, R. M. ;
Bruneliere, R. ;
Busson, P. ;
Camporesi, T. ;
Cartiglia, N. ;
Cavallari, F. ;
Cerutti, M. ;
Chamont, D. ;
Chang, P. ;
Chang, Y. H. ;
Charlot, C. ;
Chatterji, S. ;
Chen, E. A. ;
Chipaux, R. ;
Choudhary, B. C. .
JOURNAL OF INSTRUMENTATION, 2007, 2
[2]  
ADZIC P, 200818 CMS
[3]  
ADZIC P, 2006140 CMS
[4]   Radiation hard avalanche photodiodes for the CMS detector [J].
Antunovic, Z ;
Britvitch, I ;
Deiters, K ;
Godinovic, N ;
Ingram, Q ;
Kuznetsov, A ;
Musienko, Y ;
Puljak, I ;
Renker, D ;
Reucroft, S ;
Rusack, R ;
Sakhelashvili, T ;
Singovski, A ;
Soric, I ;
Swain, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 537 (1-2) :379-382
[5]   Status of PWO crystal production for the electromagnetic calorimeter of CMS and of its construction [J].
Auffray, E ;
Balog, S ;
Bouquerel, E ;
Lecoq, P ;
Schneegans, M ;
Roldan, PS .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 537 (1-2) :373-378
[6]  
AUFFRAY E, 2007, IEEE TANS NUCL SCI, V55
[7]  
BAYATIAN GL, 1997, 9733 CERNLHCC
[8]  
BAYATIAN GL, 2006001 CERNLHCC, V1
[9]   The development of vacuum phototriodes for the CMS electromagnetic calorimeter [J].
Bell, KW ;
Brown, RM ;
Cockerill, DJA ;
Flower, PS ;
Hobson, PR ;
Imrie, DC ;
Kennedy, BW ;
Lintern, AL ;
Pattison, CAX ;
Sproston, M ;
Williams, JH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 469 (01) :29-46
[10]  
*CERN LHCC, 1994, 9438 CERNLHCC