Neutron spectrum and doses in a 18 MV LINAC

被引:39
作者
Rene Vega-Carrillo, Hector [1 ]
Hernandez-Almaraz, Berenice [1 ]
Martin Hernandez-Davila, Victor [1 ]
Ortiz-Hernandez, Arturo [1 ]
机构
[1] Univ Autonoma Zacatecas, Unidad Acad Estudios Nucl, Zacatecas 98000, Zac, Mexico
关键词
Neutron spectrum; Dose; LINAC; Bonner sphere spectrometer; MONTE-CARLO; TLD PAIRS;
D O I
10.1007/s10967-009-0337-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bonner sphere spectrometer with TLDs pairs has been utilized to measure the neutron spectrum 100 cm from isocenter of a 18 MV LINAC, simultaneously the ambient dose equivalent due to neutrons and photons was measured in the control room area with neutron and gamma-ray area monitors. Measurements were carried out when the LINAC was delivering a dose of 600 MU at the isocentre that was located at 5 cm depth of a head phantom. Undesired neutron field in the treatment room produce activation reactions with nuclei in different materials of LINAC, couch, air, and phantom. To determine the dose due to decay of activation nuclei the ambient dose due to gamma-rays was measured inside the treatment room immediately after dose was delivered. Measured spectrum has two peaks, one between 0.1-1 MeV and other in the thermal region, the ambient dose equivalent in the control room are 3.1 and 0.93 mu Sv h(-1) for photons and neutrons, respectively. In the treatment room the ambient dose equivalent due to photons produced during decay of activation nuclei varies from 6 to 26.1 mu Sv h(-1).
引用
收藏
页码:261 / 265
页数:5
相关论文
共 18 条
[1]  
[Anonymous], ALASBIMN J
[2]  
[Anonymous], 1991, 1990 recommendations of the international commission on radiological protection ICRP publication 60, DOI 10.1016/0146-6453(91)90064-N
[3]  
[Anonymous], 2008, ANN ICRP
[4]   Comparison of activation products and induced dose rates in different high-energy medical linear accelerators [J].
Fischer, Helmut W. ;
Tabot, Ben ;
Poppe, Bjoern .
HEALTH PHYSICS, 2008, 94 (03) :272-278
[5]  
Followill David S, 2003, J Appl Clin Med Phys, V4, P189, DOI 10.1120/1.1571671
[6]  
Hashemi SM, 2007, NUKLEONIKA, V52, P39
[7]  
International Commission on Radiological Protection (ICRP), 1996, ANN ICRP, V26
[8]   The new remcounter LB6411: Measurement of neutron ambient dose equivalent H*(10) according to ICRP60 with high sensitivity [J].
Klett, A ;
Burgkhardt, B .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :757-759
[9]   Accelerators for cancer therapy [J].
Lennox, AJ .
RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) :223-226
[10]   Monte Carlo study of photoneutron production in the Varian Clinac 2100C linac [J].
Ma, A. ;
Awotwi-Pratt, J. ;
Alghamdi, A. ;
Alfuraih, A. ;
Spyrou, N. M. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 276 (01) :119-123