Quality control and patient dosimetry in dental cone beam CT

被引:29
作者
Vassileva, J. [1 ]
Stoyanov, D. [1 ]
机构
[1] Natl Ctr Radiobiol & Radiat Protect, Dept Radiat Protect Med Exposure, Sofia 1756, Bulgaria
关键词
TOMOGRAPHY;
D O I
10.1093/rpd/ncq011
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents the initial experience in performing quality control and patient dose measurements in a cone beam computed tomography (CT) scanner (ILUMA (TM) Ultra, IMTEC Imaging, USA) for oral and maxillofacial radiology. The X-ray tube and the generator were tested first, including the kVp accuracy and precision, and the half-value layer (HVL). The following tests specific for panoramic dental systems were also performed: tube output, beam size and beam alignment to the detector. The tests specific for CT included measurements of noise and CT numbers in water and in air, as well as the homogeneity of CT numbers. The most appropriate dose quantity was found to be the air kerma-area product (KAP) measured with a KAP-metre installed at the tube exit. KAP values were found to vary from 110 to 185 mu Gy m(2) for available adult protocols and to be 54 mu Gy m(2) for the paediatric protocol. The effective dose calculated with the software PCXMC (STUK, Finland) was 0.05 mSv for children and 0.09-0.16 mSv for adults.
引用
收藏
页码:310 / 312
页数:3
相关论文
共 10 条
[1]   Development of a quality control program for a Cone Beam CT Imaging System [J].
Benitez, Ricardo Betancourt ;
Ning, Ruola ;
Conover, David ;
Zhang, Yan ;
Cai, Weixing .
MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
[2]   Basic principles for use of dental cone beam computed tomography: consensus guidelines of the European Academy of Dental and Maxillofacial Radiology [J].
Horner, K. ;
Islam, M. ;
Flygare, L. ;
Tsiklakis, K. ;
Whaites, E. .
DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (04) :187-195
[3]   Three-dimensional cone beam computerized tomography in orthodontics [J].
Kau, C. H. ;
Richmond, S. ;
Palomo, J. M. ;
Hans, M. G. .
JOURNAL OF ORTHODONTICS, 2005, 32 (04) :282-293
[4]   Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology [J].
Ludlow, John B. ;
Ivanovic, Marija .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 106 (01) :106-114
[5]  
*MIN HLTH REP BULG, 2005, ODR PROT IND MED EXP
[6]  
PRYOR M, 2007, DENTAL CONE BEAM CT
[7]   Effective dose from cone beam CT examinations in dentistry [J].
Roberts, J. A. ;
Drage, N. A. ;
Davies, J. ;
Thomas, D. W. .
BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (973) :35-40
[8]  
Scarfe WC, 2006, J CAN DENT ASSOC, V72, P75
[9]  
Scharfe W C., 2007, Australasian Dental Practice, P102
[10]  
2009, RAD PROTECTION CONE, V1