A 10-year minimum follow-up of hydroxyapatite-coated threaded cups - Clinical, radiographic and Survivorship analyses with comparison to the literature

被引:45
作者
Epinette, JA
Manley, MT
D'Antonio, JA
Edidin, AA
Capello, WN
机构
[1] Orthopaed Res & Imaging Ctr Arthroplasty, Bruay Labuissiere, France
[2] Greater Pittsburgh Orthopaed Assoc, Moon Township, PA USA
[3] Kyphon Inc, Sunnyvale, CA USA
[4] Indiana Univ, Med Ctr, Dept Orthopaed Surg, Indianapolis, IN USA
关键词
total hip arthroplasty; acetabulum; threaded cup; hydroxyapatite coating; screw-in acetabular shell;
D O I
10.1054/arth.2003.50039
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We evaluated the clinical, radiographic, and survivorship outcomes in a series of 418 threaded hydroxyapatite-coated acetabular cups (Arc2f; Osteonics, Allendale, NJ) implanted in a consecutive series of 384 patients undergoing primary total hip arthroplasty. In all cases, the cup was screwed into the prepared acetabulum. Bone screws were used to provide secondary fixation. At a minimum 10-year follow-up, 304 cups were available for analysis. The Cumulative survivorship (mechanical failure as endpoint) at that time was 99.43% +/- 0.0104. Two hundred seventy-six hips were available for full clinical and radiographic review at or after the tenth anniversary. NO unstable implants were noted; all implant fixation interfaces were classified as "stable bone ingrown," and the cup migration rate was zero. Based on the survivorship achieved with this implant, our results compare favorably with survivorship reported for the best cemented and cementless acetabular implant designs.
引用
收藏
页码:140 / 148
页数:9
相关论文
共 75 条
[1]  
Adler E, 1992, J Arthroplasty, V7, P295, DOI 10.1016/0883-5403(92)90052-R
[2]  
APEL DM, 1989, CLIN ORTHOP RELAT R, V241, P183
[3]  
Ayerza M, 1988, ORTHOP T, V12, P662
[4]  
Barrack RL, 1997, CLIN ORTHOP RELAT R, P211
[5]  
BLOEBAUM RD, 1994, CLIN ORTHOP RELAT R, P19
[6]   RADIOGRAPHY AND HISTOLOGY OF A THREADED ACETABULAR IMPLANT - ONE CASE STUDIED AT 2 YEARS [J].
BOBYN, JD ;
ENGH, CA ;
GLASSMAN, AH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (02) :302-304
[7]   FAILURE OF THE MECRING SCREW-RING ACETABULAR COMPONENT IN TOTAL HIP-ARTHROPLASTY - A 3-YEAR TO 7-YEAR FOLLOW-UP-STUDY [J].
BRUIJN, JD ;
SEELEN, JL ;
FEENSTRA, RM ;
HANSEN, BE ;
BERNOSKI, FP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (05) :760-766
[8]   High failure rate of cementless threaded acetabular cups - A radiographic and histologic study in the goat [J].
Bruijn, JD ;
Seelen, JL ;
Veldhuizen, RW ;
Feenstra, RM ;
Bernoski, FP ;
Klopper, PJ .
ACTA ORTHOPAEDICA SCANDINAVICA, 1996, 67 (02) :133-137
[9]  
CALLAGHAN JJ, 1995, CLIN ORTHOP RELAT R, V311, P76
[10]   Hydroxyapatite-coated total hip femoral components in patients less than fifty years old - Clinical and radiographic results after five to eight years of follow-up [J].
Capello, WN ;
DAntonio, JA ;
Feinberg, JR ;
Manley, MT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (07) :1023-1029