Flow injection differential potentiometric determination of lysine by using a lysine biosensor

被引:28
作者
García-Villar, N [1 ]
Saurina, J [1 ]
Hernández-Cassou, S [1 ]
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
differential potentiometry; lysine biosensor; ammonium electrode; flow injection analysis; lysine analysis; stopped-flow; partial least squares regression;
D O I
10.1016/S0003-2670(02)01426-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a method for the determination of lysine based on a flow injection (FI) differential potentiometry system. The flow injection manifold is composed of a support electrolyte solution channel and a water channel acting as a carrier into which the sample solution is injected. The lysine biosensor was consisted of lysine oxidase chemically immobilized on a nylon membrane and attached to an all-solid-state ammonium electrode. A circular ammonium electrode was used as a reference. Hence, the possible interference of endogenous ammonium can be partly corrected by differential potentiometry. In order to increase the sensitivity of the response, the reaction was kinetically developed following a stopped-flow method. As a result, the sensitivity increased from 20 to 40 mV per decade when comparing the FI and the stopped-flow values. Furthermore, the peak-to-peak stopped-flow signals generated can be used as a more selective analytical response for lysine. The quantification of lysine in mixture samples containing small amounts of ammonium can be achieved with an acceptable accuracy, with prediction errors lower than 4%. However, when the ammonium concentration exceeded the lysine concentration, multivariate calibration with non-linear partial least squares (PLS) regression was needed to improve the lysine quantification, with an overall prediction error around 10%. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:315 / 324
页数:10
相关论文
共 29 条
  • [1] ENZYME IMMOBILIZATION ON AN EPOXY MATRIX - DETERMINATION OF L-ARGININE BY FLOW-INJECTION TECHNIQUES
    ALONSO, A
    ALMENDRAL, MJ
    BAEZ, MD
    PORRAS, MJ
    ALONSO, C
    [J]. ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) : 164 - 169
  • [2] Usefulness of a ruggedness test in the validation of flow injection analysis systems
    Alvares-Ribeiro, LMBC
    Machado, AASC
    [J]. ANALYTICA CHIMICA ACTA, 1997, 355 (2-3) : 195 - 201
  • [3] Optimization of a bipotentiometric flow injection analysis system for simultaneous determination of calcium and chloride ions in natural waters
    Alvares-Ribeiro, LMBC
    Machado, AASC
    [J]. ANALYST, 1998, 123 (04) : 653 - 659
  • [4] Electroanalysis: From laboratory to field versions
    Brainina, KZ
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 56 (04) : 303 - 312
  • [5] Design of the fluoride ion-selective electrode as tubular detector for flow injection analysis
    Bralic, M
    Generalic, E
    Krka, S
    [J]. ANALYTICAL LETTERS, 2000, 33 (09) : 1811 - 1825
  • [6] Tetracycline, oxytetracycline and chlortetracycline determination by flow injection potentiometry
    Couto, CMCM
    Lima, JLFC
    Conceiçao, M
    Montenegro, BSM
    Reis, S
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (4-5) : 527 - 533
  • [7] Dimitrakopoulos LT, 2001, ELECTROANAL, V13, P161, DOI 10.1002/1521-4109(200102)13:2<161::AID-ELAN161>3.0.CO
  • [8] 2-R
  • [9] Potentiometric sensor array for the determination of lysine in feed samples using multivariate calibration methods
    García-Villar, N
    Saurina, J
    Hernández-Cassou, S
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (07): : 1001 - 1008
  • [10] Flow injection analysis of sulfite ion with a potentiometric titanium phosphate-epoxy based membrane sensor
    Hassan, SSM
    Marei, SA
    Badr, IH
    Arida, HA
    [J]. TALANTA, 2001, 54 (04) : 773 - 782