Extracorporeal acute cardiac pacing by High Intensity Focused Ultrasound

被引:21
作者
Livneh, Amit [1 ]
Kimmel, Eitan [1 ]
Kohut, Andrew R. [2 ]
Adam, Dan [1 ]
机构
[1] Technion Israel Inst Technol, Dept Biomed Engn, IL-32000 Haifa, Israel
[2] Drexel Univ, Coll Med, Div Cardiol, Dept Med, Philadelphia, PA 19102 USA
关键词
Cardiac pacing; Ultrasound; Therapeutic; Focused; Imaging; Real-time; MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY; CONTRACTION-EXCITATION FEEDBACK; MECHANICAL STIMULATION; INDUCED ARRHYTHMIAS; PULSED ULTRASOUND; ACTION-POTENTIALS; DEPENDENT CHANGES; GAS-BUBBLES; FROG-HEART; IN-VIVO;
D O I
10.1016/j.pbiomolbio.2014.08.007
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Ultrasound has been shown to produce Premature Ventricular Contractions (PVC's). Two clinical applications in which acute cardiac pacing by ultrasound may be valuable are: (1) preoperative patient screening in cardiac resynchronization therapy surgery; (2) Emergency life support, following an event of sudden death, caused by cardiac arrest. Yet, previously the demonstrated mean success rate of extrasystole induction by High Intensity Focused Ultrasound (HIFU) in rats is below 4.5% (Miller et al., 2011). This stands in contrast to previous work in rats using ultrasound (US) and ultrasound contrast agents (UCAs), where success rates of close to 100% were reported (Rota et al., 2006). Herein, bi-stage temporal sequences of accentuated negative pressure (rarefaction) and positive pressure HIFU transmission (insonation) patterns were applied to anaesthetized rats under real-time vital-signs monitoring and US imaging. This pattern of insonation first produces a gradual growth of dissolved gas cavities in tissue (cavitation) and then an ultrasonic impact. Results demonstrate sequences of successive successful HIFU pacing. Triggering insonation at different delays from the preceding ECG R-wave demonstrated successful HIFU pacing induction from mid ECG T-wave till the next ECG complex's PR interval. Spatially focusing the beam at different locations allows cumulative coverage of the whole left ventricle. Analysis of the acoustic wave patterns and temporal characteristics of paced PVCs is suggested to provide new insight into the mechanisms of HIFU cardiac pacing. Specifically, the observed HIFU pacing temporal success rate distribution suggests against sarcomere length modulation current being the dominant cellular level mechanism of HIFU cardiac pacing and may allow postulating that membrane deformation currents are dominant at the applied insonation conditions. (C) 2014 Published by Elsevier Ltd.
引用
收藏
页码:140 / 153
页数:14
相关论文
共 72 条
[1]   COMPARATIVE ANALYSIS OF ANTEGRADE AND RETROGRADE CONDUCTION PATTERNS IN MAN [J].
AKHTAR, M ;
DAMATO, AN ;
BATSFORD, WP ;
RUSKIN, JN ;
OGUNKELU, JB .
CIRCULATION, 1975, 52 (05) :766-778
[2]   CALCIUM-CONCENTRATION IN THE MYOPLASM OF SKINNED FERRET VENTRICULAR MUSCLE FOLLOWING CHANGES IN MUSCLE LENGTH [J].
ALLEN, DG ;
KENTISH, JC .
JOURNAL OF PHYSIOLOGY-LONDON, 1988, 407 :489-503
[3]   LOCAL-EFFECTS OF ELECTRICAL AND MECHANICAL STIMULATION ON THE RECOVERY PROPERTIES OF THE CANINE VENTRICLE [J].
AVITALL, B ;
LEVINE, HJ ;
NAIMI, S ;
DONAHUE, RP ;
PAUKER, SG ;
ADAM, D .
AMERICAN JOURNAL OF CARDIOLOGY, 1982, 50 (02) :263-270
[4]   A review of therapeutic ultrasound: Biophysical effects [J].
Baker, KG ;
Robertson, VJ ;
Duck, FA .
PHYSICAL THERAPY, 2001, 81 (07) :1351-1358
[5]   Systems approach to the study of stretch and arrhythmias in right ventricular failure induced in rats by monocrotaline [J].
Benoist, David ;
Stones, Rachel ;
Benson, Alan P. ;
Fowler, Ewan D. ;
Drinkhill, Mark J. ;
Hardy, Matthew E. L. ;
Saint, David A. ;
Cazorla, Olivier ;
Bernus, Olivier ;
White, Ed .
PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 2014, 115 (2-3) :162-172
[6]   Cardiac excitation-contraction coupling [J].
Bers, DM .
NATURE, 2002, 415 (6868) :198-205
[7]   Calcium fluxes involved in control of cardiac myocyte contraction [J].
Bers, DM .
CIRCULATION RESEARCH, 2000, 87 (04) :275-281
[8]   Mechanosensitivity of N-type calcium channel currents [J].
Calabrese, B ;
Tabarean, IV ;
Juranka, P ;
Morris, CE .
BIOPHYSICAL JOURNAL, 2002, 83 (05) :2560-2574
[9]   Spontaneous homogeneous nucleation, inertial cavitation and the safety of diagnostic ultrasound [J].
Church, CC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (10) :1349-1364
[10]  
Church CC, 2006, AIP CONF PROC, V838, P217