Evaluation study on structural fault of a Renaissance Italian palace

被引:42
作者
Betti, Michele [1 ]
Bartoli, Gianni [1 ]
Orlando, Maurizio [1 ]
机构
[1] Univ Florence, Dept Civil & Environm Engn DICeA, I-50139 Florence, Italy
关键词
Masonry buildings; Damage assessment; Finite element analysis; Limit analysis; SEISMIC VULNERABILITY; MASONRY BUILDINGS; CHURCH;
D O I
10.1016/j.engstruct.2010.03.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper discusses the cracking pattern in a historical Italian palace proposing a diagnosis for the origin of the actual damage state. The analyzed building, which dates back to the seventeenth century, is a masonry building with a rectangular plan section located in Piancastagnaio (South Tuscany, Italy). The building exhibits a severe and variegated vertical and horizontal cracking pattern mainly affecting the southern and eastern facades. Due to the damage, the palace was evacuated by the Public Authorities during the 1980s and a series of provisional remedies (mainly steel chains) was added. Through the use of the finite element technique, the paper provides an interpretation of the manifested damage. The aim of the diagnosis, supported by the numerical results, is to design an extensive in-situ investigation on the palace. Moreover, the paper aims at evaluating the effectiveness of the actual temporary retrofitting (mainly steel chains) used to freeze the present damage. At the end of the paper the in-situ investigation is presented and discussed. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1801 / 1813
页数:13
相关论文
共 31 条
[1]  
[Anonymous], 2006, P INT C STRUCT AN HI
[2]   Experimental and numerical analyses for static retrofitting intervention on the "Cappella dei Principi" in Firenze [J].
Antonelli, A. ;
Bartoli, G. ;
Betti, M. .
STRUCTURAL ANALYSIS OF HISTORIC CONSTRUCTION: PRESERVING SAFETY AND SIGNIFICANCE, VOLS 1 AND 2, 2008, :899-907
[3]  
ANTONELLI A, 2008, P 6 INT C STRUCT AN, V2, P899
[4]  
ANTONELLI A, 2006, WORKSH DES REH MAS S, P277
[5]  
BALDI AM, 2007, PRELIMINARY GEOLOGIC
[6]   Seismic evaluation of old masonry buildings. Part II: Analysis of strengthening solutions for a case study [J].
Bento, R ;
Lopes, M ;
Cardoso, R .
ENGINEERING STRUCTURES, 2005, 27 (14) :2014-2023
[7]  
BETTI M, 2009, P 12 INT C CIV STRUC, V1, P1
[8]  
BETTI M, 2008, P 6 INT C STRUCT AN, V1, P601
[9]   Modelling and analysis of a Romanesque church under earthquake loading: Assessment of seismic resistance [J].
Betti, Michele ;
Vignoli, Andrea .
ENGINEERING STRUCTURES, 2008, 30 (02) :352-367
[10]   A micromechanical inelastic model for historical masonry [J].
Calderini, C. ;
Lagomarsino, S. .
JOURNAL OF EARTHQUAKE ENGINEERING, 2006, 10 (04) :453-479