National Consensus in the Use of the Flash Glucose Monitoring System in Portugal

被引:2
作者
Cardoso, Helena [1 ,2 ]
Carvalho, Davide [3 ,4 ,5 ]
Pape, Estevao [6 ,7 ]
Carrilho, Francisco [8 ]
Raposo, Joao Filipe [9 ,10 ,11 ]
Melo, Miguel [8 ,12 ,13 ]
Carvalho, Ema [14 ]
Duarte, Rui [11 ,15 ]
机构
[1] Univ Porto, Med Sch, Porto, Portugal
[2] Porto Hosp & Univ Ctr, Endocrinol Diabet & Metab Serv, Porto, Portugal
[3] Univ Porto, Portuguese Soc Endocrinol Diabet & Metab, Porto, Portugal
[4] Univ Porto, Fac Med, Porto, Portugal
[5] Ctr Hosp Univ S Joeia, Dept Endocrinol Diabet & Metab, Porto, Portugal
[6] Portuguese Soc Internal Med, Diabet Mellitus Ctr Studies, Almada, Portugal
[7] Garcia Orta Hosp, Almada, Portugal
[8] Coimbra Univ & Hosp Ctr, Endocrinol Diabet & Metab Serv, Coimbra, Portugal
[9] Univ Nova Lisboa, Portuguese Soc Diabetol, Lisbon, Portugal
[10] Univ Nova Lisboa, Publ Hlth, Med Sci Fac, Lisbon, Portugal
[11] Portuguese Diabet Assoc APDP, Lisbon, Portugal
[12] Coimbra Univ, Portuguese Soc Endocrinol Diabet & Metab, Coimbra, Portugal
[13] Coimbra Univ, Med Sch, Coimbra, Portugal
[14] Sao Joao Hosp & Univ Ctr, Day Hosp, Endocrinol Diabet & Metab Serv, Porto, Portugal
[15] Portuguese Soc Diabetol, Lisbon, Portugal
关键词
Blood Glucose Self-Monitoring/methods; Consensus; Diabetes Mellitus; Type; 1/blood; Portugal; Wearable Electronic Devices; G5 CGM SYSTEM; SENSING TECHNOLOGY; GLYCEMIC VARIABILITY; PRACTICAL APPROACH; TREND ARROWS; PROFILE; REPLACEMENT; MANAGEMENT; HYPOGLYCEMIA; ASSOCIATION;
D O I
10.1016/j.rpedm.14.1.NA190022
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Monitoring of glucose levels is essential in the management of diabetes, particularly in insulin therapy. The flash glucose monitoring system FreeStyle Libre (R) is an intermittent continuous monitoring system that adds a set of new data to the traditional blood glucose determinations and that, when properly used, can lead to better glucose control through more personalized and rigorous clinical advice, as well as greater involvement and responsibility of the patients in the management of their condition. The recommendations outlined here aim to guide and standardize clinical practice and communication with the patient, namely: 1) New parameters for glucose assessment 2) Reading and interpretation of the ambulatory glucose profile (AGP) and 3) Interpretation of trend arrows and therapeutic adjustments.
引用
收藏
页码:74 / 81
页数:8
相关论文
共 38 条
[1]  
Aleppo G, 2017, J ENDOCR SOC, V1, P1445, DOI 10.1210/js.2017-00388
[2]  
[Anonymous], FREEST LIBR US MAN
[3]  
[Anonymous], 2014, BRIT J DIABETES VASC, DOI [10.15277/bjdvd.2014.046, DOI 10.15277/bjdvd.2014.046]
[4]  
[Anonymous], DIABETES S1
[5]  
[Anonymous], 2016, CLIN REVS
[6]  
[Anonymous], DIABETES S1
[7]   Glucose Management Indicator (GMI): A New Term for Estimating A1C From Continuous Glucose Monitoring [J].
Bergenstal, Richard M. ;
Beck, Roy W. ;
Close, Kelly L. ;
Grunberger, George ;
Sacks, David B. ;
Kowalski, Aaron ;
Brown, Adam S. ;
Heinemann, Lutz ;
Aleppo, Grazia ;
Ryan, Donna B. ;
Riddlesworth, Tonya D. ;
Cefalu, William T. .
DIABETES CARE, 2018, 41 (11) :2275-2280
[8]  
Bergenstal Richard M, 2013, J Diabetes Sci Technol, V7, P562
[9]   Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial [J].
Bolinder, Jan ;
Antuna, Ramiro ;
Geelhoed-Duijvestijn, Petronella ;
Kroeger, Jens ;
Weitgasser, Raimund .
LANCET, 2016, 388 (10057) :2254-2263
[10]   Use of the DirecNet Applied Treatment Algorithm (DATA) for diabetes management with a real-time continuous glucose monitor (the FreeStyle Navigator) [J].
Buckingham, Bruce ;
Xing, Dongyuan ;
Weinzimer, Stu ;
Fiallo-Scharer, Rosanna ;
Kollman, Craig ;
Mauras, Nelly ;
Tsalikian, Eva ;
Tamborlane, William ;
Wysocki, Tim ;
Ruedy, Katrina ;
Beck, Roy .
PEDIATRIC DIABETES, 2008, 9 (02) :142-147