Slit design for efficient and accurate MTF measurement at megavoltage x-ray energies

被引:15
作者
Sawant, Arnit [1 ]
Antonuk, Larry [1 ]
El-Mohri, Youcef [1 ]
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48103 USA
关键词
modulation transfer function; MTF measurement; slit method; megavoltage x-ray imaging; portal imaging; PANEL IMAGER AMFPI; TO-NOISE ANALYSIS; FLAT-PANEL; QUANTUM EFFICIENCY; PERFORMANCE; DETECTORS; RADIOTHERAPY; PROTOTYPE; SYSTEM;
D O I
10.1118/1.2717405
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Empirical determination of the modulation transfer function (MTF) for analog and digital megavoltage x-ray imagers is a challenging task. The most common method used to determine MTF at megavoltage x-ray energies employs a long, narrow slit formed by two parallel, metal blocks in order to form a "slit beam." In this work, a detailed overview of some of the important considerations of slit design is presented. Based on these considerations, a novel, compact slit, using 19 cm thick tungsten blocks, was designed. The prototype slit was configured to attach to the accessory slot of the gantry of a linear accelerator, which greatly simplified the measurement process. Measurements were performed to determine the presampling MTF at 6 MV for an indirect detection active matrix flat panel imager prototype previously developed for megavoltage imaging applications. In addition, the effects of two important slit design parameters, material type and thickness, on the accuracy of MTF determination were investigated via a Monte Carlo-based theoretical study. Empirically determined MTFs obtained from the prototype slit closely match those from an earlier, less compact slit design based on 40 cm thick steel blocks. The results of the Monte Carlo-based theoretical studies indicate that the prototype slit achieves close-to-ideal performance in terms of accurately determining the MTF by virtue of practically 100% beam attenuation in regions other than the slit gap. Furthermore, the theoretical results suggest that it may be possible to achieve even further reductions in slit thickness without compromising measurement accuracy. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1535 / 1545
页数:11
相关论文
共 50 条
  • [41] Nano-precision metrology of X-ray mirrors with laser speckle angular measurement
    Wang, Hongchang
    Moriconi, Simone
    Sawhney, Kawal
    LIGHT-SCIENCE & APPLICATIONS, 2021, 10 (01)
  • [42] Theory and optical design of x-ray echo spectrometers
    Shvyd'ko, Yuri
    PHYSICAL REVIEW A, 2017, 96 (02)
  • [43] Development of high quantum efficiency, flat panel, thick detectors for megavoltage x-ray imaging: An experimental study of a single-pixel prototype
    Mei, X
    Pang, G
    MEDICAL PHYSICS, 2005, 32 (11) : 3379 - 3388
  • [44] Experimental study of a single-pixel prototype anti-scatter detector for megavoltage x-ray imaging
    Tian, Y.
    Pang, G.
    RADIATION PHYSICS AND CHEMISTRY, 2016, 119 : 9 - 13
  • [45] Real-time segmentation of multiple implanted cylindrical liver markers in kilovoltage and megavoltage x-ray images
    Fledelius, W.
    Worm, E.
    Hoyer, M.
    Grau, C.
    Poulsen, P. R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (11) : 2787 - 2800
  • [46] The X-ray quantum efficiency measurement of high resistivity CCDs
    Murray, Neil J.
    Holland, Andrew D.
    Smith, David R.
    Gow, Jason P.
    Pool, Peter J.
    Burt, David J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2) : 180 - 182
  • [47] Quantum efficiency measurement of the X-ray CCD camera (XIS) for the ASTRO-E mission in the soft X-ray band
    Kohmura, T
    Katayama, K
    Katayama, H
    Shouho, M
    Tsunemi, H
    Kitamoto, S
    Hayashida, K
    Miyata, E
    Ohtani, M
    Ohta, M
    Yoshita, K
    Koyama, K
    Ricker, G
    Bautz, MW
    Foster, R
    Kissel, S
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 : 588 - 596
  • [48] Comparative Investigation of Ce3+ Doped Scintillators in a Wide Range of Photon Energies Covering X-ray CT, Nuclear Medicine and Megavoltage Radiation Therapy Portal Imaging Applications
    Valais, Ioannis G.
    Michail, Christos M.
    David, Stratos L.
    Liaparinos, Panagiotis F.
    Fountos, George P.
    Paschalis, Theodoros V.
    Kandarakis, Ioannis S.
    Panayiotakis, George S.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 3 - 7
  • [49] Intramolecular charge transfer enables highly-efficient X-ray luminescence in cluster scintillators
    Zhang, Nan
    Qu, Lei
    Dai, Shuheng
    Xie, Guohua
    Han, Chunmiao
    Zhang, Jing
    Huo, Ran
    Hu, Huan
    Chen, Qiushui
    Huang, Wei
    Xu, Hui
    NATURE COMMUNICATIONS, 2023, 14 (01)
  • [50] Highly efficient eco-friendly X-ray scintillators based on an organic manganese halide
    Xu, Liang-Jin
    Lin, Xinsong
    He, Qingquan
    Worku, Michael
    Ma, Biwu
    NATURE COMMUNICATIONS, 2020, 11 (01)