Slit design for efficient and accurate MTF measurement at megavoltage x-ray energies

被引:15
作者
Sawant, Arnit [1 ]
Antonuk, Larry [1 ]
El-Mohri, Youcef [1 ]
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48103 USA
关键词
modulation transfer function; MTF measurement; slit method; megavoltage x-ray imaging; portal imaging; PANEL IMAGER AMFPI; TO-NOISE ANALYSIS; FLAT-PANEL; QUANTUM EFFICIENCY; PERFORMANCE; DETECTORS; RADIOTHERAPY; PROTOTYPE; SYSTEM;
D O I
10.1118/1.2717405
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Empirical determination of the modulation transfer function (MTF) for analog and digital megavoltage x-ray imagers is a challenging task. The most common method used to determine MTF at megavoltage x-ray energies employs a long, narrow slit formed by two parallel, metal blocks in order to form a "slit beam." In this work, a detailed overview of some of the important considerations of slit design is presented. Based on these considerations, a novel, compact slit, using 19 cm thick tungsten blocks, was designed. The prototype slit was configured to attach to the accessory slot of the gantry of a linear accelerator, which greatly simplified the measurement process. Measurements were performed to determine the presampling MTF at 6 MV for an indirect detection active matrix flat panel imager prototype previously developed for megavoltage imaging applications. In addition, the effects of two important slit design parameters, material type and thickness, on the accuracy of MTF determination were investigated via a Monte Carlo-based theoretical study. Empirically determined MTFs obtained from the prototype slit closely match those from an earlier, less compact slit design based on 40 cm thick steel blocks. The results of the Monte Carlo-based theoretical studies indicate that the prototype slit achieves close-to-ideal performance in terms of accurately determining the MTF by virtue of practically 100% beam attenuation in regions other than the slit gap. Furthermore, the theoretical results suggest that it may be possible to achieve even further reductions in slit thickness without compromising measurement accuracy. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1535 / 1545
页数:11
相关论文
共 50 条
  • [31] MOSFET dosimetry in-vivo at superficial and orthovoltage x-ray energies
    T. Cheung
    M. J. Butson
    P. K. N. Yu
    Australasian Physics & Engineering Sciences in Medicine, 2003, 26 (2): : 81 - 83
  • [32] Efficient methods of X-ray diffraction pattern inversion
    Shuttleworth, Ian Gregory
    RESULTS IN PHYSICS, 2019, 15
  • [33] X-Ray Single-Grating Interferometry for Wavefront Measurement and Correction of Hard X-Ray Nanofocusing Mirrors
    Yamada, Jumpei
    Inoue, Takato
    Nakamura, Nami
    Kameshima, Takashi
    Yamauchi, Kazuto
    Matsuyama, Satoshi
    Yabashi, Makina
    SENSORS, 2020, 20 (24) : 1 - 12
  • [34] The accurate assessment of small-angle X-ray scattering data
    Grant, Thomas D.
    Luft, Joseph R.
    Carter, Lester G.
    Matsui, Tsutomu
    Weiss, Thomas M.
    Martel, Anne
    Snell, Edward H.
    ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 2015, 71 : 45 - 56
  • [35] Performance of a new star-bar phantom designed for MTF calculations in x-ray imaging systems
    Gonzalez-Lopez, Antonio
    Campos-Morcillo, Pedro-Antonio
    Vera-Sanchez, Juan Antonio
    Ruiz-Morales, Carmen
    MEDICAL PHYSICS, 2020, 47 (10) : 4949 - 4955
  • [36] Modulation transfer function (MTF) evaluation for x-ray phase imaging system employing attenuation masks
    Havariyoun, Glafkos
    Massimi, Lorenzo
    Hagen, Charlotte
    Endrizzi, Marco
    Olivo, Alessandro
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (09)
  • [37] Novel detector design for reducing intercell x-ray cross-talk in the variable resolution x-ray CT scanner: A Monte Carlo study
    Arabi, Hosein
    Asl, Ali Reza Kamali
    Ay, Mohammad Reza
    Zaidi, Habib
    MEDICAL PHYSICS, 2011, 38 (03) : 1389 - 1396
  • [38] Nano-precision metrology of X-ray mirrors with laser speckle angular measurement
    Wang, Hongchang
    Moriconi, Simone
    Sawhney, Kawal
    LIGHT-SCIENCE & APPLICATIONS, 2021, 10 (01)
  • [39] Design and Performance Test of Pulse X-Ray Receiver Based on LYSO-SiPM for X-Ray Communication
    Mu, Junxu
    Tang, Xiaobin
    Liu, Yunpeng
    Lai, Sheng
    Feng, Zhaopeng
    Chen, Wenxuan
    Wang, Yiyang
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2022, 40 (13) : 4217 - 4223
  • [40] Portable x-ray fluorescence for bone lead measurement: Current approaches and future directions
    Specht, Aaron J.
    Hoover, Christian
    Grier, Thomas
    CURRENT ENVIRONMENTAL HEALTH REPORTS, 2024, 11 (03) : 443 - 451