共 50 条
Temporal artery biopsy size does not matter
被引:10
作者:
Kaptanis, Sarantos
[1
]
Perera, Joanne K.
[1
]
Halkias, Constantine
[2
]
Caton, Nadine
[1
]
Alarcon, Lida
[1
]
Vig, Stella
[1
]
机构:
[1] Croydon Univ Hosp, London CR7 7YE, England
[2] Imperial Coll Healthcare NHS Trust, London, England
来源:
关键词:
Giant cell arteritis;
temporal artery biopsy;
size;
ACR criteria;
GIANT-CELL ARTERITIS;
SPECIMEN LENGTH;
SKIP LESIONS;
DIAGNOSIS;
CLASSIFICATION;
MANAGEMENT;
EFFICACY;
D O I:
10.1177/1708538113516322
中图分类号:
R6 [外科学];
学科分类号:
1002 ;
100210 ;
摘要:
This study aimed to clarify whether positive temporal artery biopsies had a greater sample length than negative biopsies in temporal arteritis. It has been suggested that biopsy length should be at least 1 cm to improve diagnostic accuracy. A retrospective review of 149 patients who had 151 temporal artery biopsies was conducted. Twenty biopsies were positive (13.3%), 124 negative (82.1%) and seven samples were insufficient (4.6%). There was no clinically significant difference in the mean biopsy size between positive (0.7 cm) and negative samples (0.65 cm) (t-test: p = .43 NS). Ninety-four patients fulfilled all three ACR criteria prior to biopsy (62.3%) and four patients (2.6%) changed ACR score from 2 to 3 after biopsy. Treatment should not be delayed in anticipation of the biopsy or withheld in the case of a negative biopsy if the patient's symptoms improve.