Electromyography-controlled exoskeletal upper-limb-powered orthosis for exercise training after stroke

被引:121
作者
Stein, Joel
Narendran, Kailas
McBean, John
Krebs, Kathryn
Hughes, Richard
机构
[1] Spaulding Rehabil Hosp, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Dept Phys Med & Rehabil, Boston, MA USA
[3] MIT, Act Joint Brace Res Lab, Dept Mech Engn, Boston, MA USA
[4] Myomo Inc, Boston, MA USA
关键词
robots; EMG; stroke; exercise; hemiparesis;
D O I
10.1097/PHM.0b013e3180383cc5
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: Robot-assisted exercise shows promise as a means of providing exercise therapy for weakness that results from stroke or other neurological conditions. Exoskeletal or "wearable" robots can, in principle, provide therapeutic exercise and/or function as powered orthoses to help compensate for chronic weakness. We describe a novel electromyography (EMG)-controlled exoskeletal robotic brace for the elbow (the active joint brace) and the results of a pilot study conducted using this brace for exercise training in individuals with chronic hemiparesis after stroke. Design: Eight stroke survivors with severe chronic hemiparesis were enrolled in this pilot study. One subject withdrew from the study because of scheduling conflicts. A second subject was,unable to participate in the training protocol because of insufficient surface EMG activity to control the active joint brace. The six remaining subjects each underwent 18 hrs of exercise training using the device for a period of 6 wks. Outcome measures included the upper-extremity component of the Fugl-Meyer scale and the modified Ashworth scale of muscle hypertonicity. Results: Analysis revealed that the mean upper-extremity component of the Fugl-Meyer scale increased from 15.5 (SD 3.88) to 19 (SD 3.95) (P = 0.04) at the conclusion of training for the six subjects who completed training. Combined (summated) modified Ashworth scale for the elbow flexors and extensors improved from 4.67 (+/- 1.2 SD) to 2.33 (+/- 0.653 SD) (P = 0.009) and improved for the entire upper limb as well. All subjects tolerated the device, and no complications occurred. Conclusion: EMG-controlled powered elbow orthoses can be successfully controlled by severely impaired hemiparetic stroke survivors. This technique shows promise as a new modality for assisted exercise training after stroke.
引用
收藏
页码:255 / 261
页数:7
相关论文
共 29 条
[1]   The effect of robot-assisted therapy and rehabilitative training on motor recovery following stroke [J].
Aisen, ML ;
Krebs, HI ;
Hogan, N ;
McDowell, F ;
Volpe, BT .
ARCHIVES OF NEUROLOGY, 1997, 54 (04) :443-446
[2]   INTERRATER RELIABILITY OF A MODIFIED ASHWORTH SCALE OF MUSCLE SPASTICITY [J].
BOHANNON, RW ;
SMITH, MB .
PHYSICAL THERAPY, 1987, 67 (02) :206-207
[3]   Intramuscular injection of botulinum toxin for the treatment of wrist and finger spasticity after a stroke [J].
Brashear, A ;
Gordon, MF ;
Elovic, E ;
Kassicieh, VD ;
Marciniak, C ;
Lee, CH ;
Jenkins, S ;
Turkel, C .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (06) :395-400
[4]   Improving elbow torque output of stroke patients with assistive torque controlled by EMG signals [J].
Cheng, HS ;
Ju, MS ;
Lin, CCK .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (06) :881-886
[5]   A functional MRI study of subjects recovered from hemiparetic stroke [J].
Cramer, SC ;
Nelles, G ;
Benson, RR ;
Kaplan, JD ;
Parker, RA ;
Kwong, KK ;
Kennedy, DN ;
Finklestein, SP ;
Rosen, BR .
STROKE, 1997, 28 (12) :2518-2527
[6]   Customized interactive robotic treatment for stroke: EMG-triggered therapy [J].
Dipietro, L ;
Ferraro, M ;
Palazzolo, JJ ;
Krebs, HI ;
Volpe, BT ;
Hogan, N .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2005, 13 (03) :325-334
[7]   Effects of robotic therapy on motor impairment and recovery in chronic stroke [J].
Fasoli, SE ;
Krebs, HI ;
Stein, J ;
Frontera, WR ;
Hogan, N .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2003, 84 (04) :477-482
[8]   Robot-aided sensorimotor arm training improves outcome in patients with chronic stroke [J].
Ferraro, M ;
Palazzolo, JJ ;
Krol, J ;
Krebs, HI ;
Hogan, N ;
Volpe, BT .
NEUROLOGY, 2003, 61 (11) :1604-1607
[9]   An ankle-foot orthosis powered by artificial pneumatic muscles [J].
Ferris, DP ;
Czerniecki, JM ;
Hannaford, B .
JOURNAL OF APPLIED BIOMECHANICS, 2005, 21 (02) :189-197
[10]  
FUGLMEYER AR, 1975, SCAND J REHABIL MED, V7, P13