Intraexaminer Reliability of Hand-Held Dynamometry in the Upper Extremity: A Systematic Review

被引:101
作者
Schrama, Patrick P. M. [1 ]
Stenneberg, Martijn S. [1 ]
Lucas, Cees [2 ]
van Trijffel, Emiel [1 ,2 ]
机构
[1] Inst Master Educ Musculoskeletat Therapy, Stichting Opleidingen Musculoskeletale Therapie, Amersfoort, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Clin Epidemiol Biostatist & Bioinformat, NL-1105 AZ Amsterdam, Netherlands
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2014年 / 95卷 / 12期
关键词
Extremities; Isometric contraction; Muscle strength dynamometer; Observer variation; Rehabilitation; Reproducibility of results; ISOMETRIC MUSCLE FORCE; ASSESS MUSCULAR STRENGTH; NONSPECIFIC NECK PAIN; SPINAL-CORD-INJURY; INTERRATER RELIABILITY; DIAGNOSTIC-ACCURACY; RETEST RELIABILITY; ISOKINETIC DYNAMOMETRY; CLINIMETRIC EVALUATION; MENTAL-RETARDATION;
D O I
10.1016/j.apmr.2014.05.019
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To summarize and appraise the literature on the intraexaminer reliability of hand-held dynamometry (HHD) in the upper extremity. Data Sources: MEDLINE, CINAHL, and EMBASE were searched for relevant studies published up to December 2011. In addition, experts were contacted, and journals and reference lists were hand searched. Study Selection: To be included in the review, articles needed to (1) use a repeated-measures, within-examiner(s) design; (2) include symptomatic or asymptomatic individuals, or both; (3) use BED to measure muscle strength in any of the joints of the shoulder, elbow, or wrist with the "make" or the "break" technique; (4) report measurements in kilogram, pound, or torque; (5) use a device that is placed between the examiner's hand and the subject's body; and (6) present estimates of intraexaminer reliability. Data Extraction: Quality assessment and data extraction were performed by 2 reviewers independently. Data Synthesis: Fifty-four studies were included, of which 26 (48%) demonstrated acceptable intraexaminer reliability. Seven high-quality studies showed acceptable reliability for flexion and extension of the elbow in healthy subjects. Conflicting results were found for shoulder external rotation and abduction. Reliability for all other movements was unacceptable. Higher estimates were reached for within-sessions reliability and if means of trials were used. Conclusions: Intraexaminer reliability of HHD in upper extremity muscle strength was acceptable only for elbow measurements in healthy subjects. We provide specific recommendations for future research. Physical therapists should not rely on HHD measurements for evaluation of treatment effects in patients with upper extremity disorders. (C) 2014 by the American Congress of Rehabilitation Medicine
引用
收藏
页码:2444 / 2469
页数:26
相关论文
共 120 条
[51]   Isometric Muscle Strength in Youth Assessed by Hand-held Dynamometry: A Feasibility, Reliability, and Validity Study [J].
Hebert, Luc J. ;
Maltais, Desiree B. ;
Lepage, Celine ;
Saulnier, Joanne ;
Crete, Melanie ;
Perron, Marc .
PEDIATRIC PHYSICAL THERAPY, 2011, 23 (03) :289-299
[52]  
Hedengren E, 2001, SCAND J RHEUMATOL, V30, P69
[53]  
Hopman K, CLIN PRACTICE GUIDEL
[54]  
Horvat M, 1992, ISOKINETICS EXERCISE, V2, P175
[55]   MEASUREMENTS OF MUSCLE STRENGTH AND PERFORMANCE IN CHILDREN WITH NORMAL AND DISEASED MUSCLE [J].
HOSKING, GP ;
BHAT, US ;
DUBOWITZ, V ;
EDWARDS, RHT .
ARCHIVES OF DISEASE IN CHILDHOOD, 1976, 51 (12) :957-963
[56]  
Jobst Andrea, 2013, Open Respir Med J, V7, P33, DOI 10.2174/1874306401307010033
[57]   Intraobserver and interobserver reliability for the strength test in the Constant-Murley shoulder assessment [J].
Johansson, KM ;
Adolfsson, LF .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (03) :273-278
[58]   Hand-held dynamometry: Reliability of lower extremity muscle testing in healthy, physically active, young adults [J].
Kelln, Brent M. ;
McKeon, Patrick O. ;
Gontkof, Lauren M. ;
Hertel, Jay .
JOURNAL OF SPORT REHABILITATION, 2008, 17 (02) :160-170
[59]   Hand-held dynamometry reliability in persons with neuropathic weakness [J].
Kilmer, DD ;
McCrory, MA ;
Wright, NC ;
Rosko, RA ;
Kim, HR ;
Aitkens, SG .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1997, 78 (12) :1364-1368
[60]  
Kimura I.F., 1996, J SPORT REHABIL, V5, P197, DOI 10.1123/jsr.5.3.197