Temporal subtraction technique for detection of interval changes on digital chest radiographs by using an elastic matching technique

被引:0
作者
Li, Q [1 ]
Katsuragawa, S [1 ]
Doi, K [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
来源
MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2 | 2000年 / 3979卷
关键词
temporal subtraction; elastic matching; nonlinear image warping;
D O I
10.1117/12.387642
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have been developing a temporal subtraction technique to assist radiologists in the detection of interval changes of pulmonary abnormalities on digital chest radiographs. By subtracting a previous image from an current one, a temporal subtraction image is obtained, in which the lesions can be enhanced because skeletal structures such as ribs and clavicles are eliminated. Although the quality of the subtraction images obtained with our previous technique is relatively good, minor misregistration artifacts were observed in many cases because of the use of polynomial fitting of shift values. In this study, we employed three new techniques to reduce the misregistration artifacts in the temporal subtraction images. The first was a rib edge matching technique which was used to align the rib structures approximately in the two images. The second was an increase in the number of template and search area regions of interest (ROIs) in the two images. The third was the use of an elastic matching technique for the replacement of the polynomial fitting technique employed in the previous subtraction technique. With the new techniques, the quality of subtraction images was improved significantly. In particular, the number of subtraction images with excellent quality was greatly increased from 37% to 57%.
引用
收藏
页码:1331 / 1341
页数:5
相关论文
共 12 条
  • [1] BAJSCY R, 1982, P 6 INT C PATT REC, P351
  • [2] BAJSCY R, 1989, COMPUT VISION GRAPH, V46, P1
  • [3] Davis L.S., 1975, Comput. Graph. Image Process., V4, P248
  • [4] Digital chest radiography: Effect of temporal subtraction images on detection accuracy
    Difazio, MC
    MacMahon, H
    Xu, XW
    Tsai, P
    Shiraishi, J
    Armato, SG
    Doi, K
    [J]. RADIOLOGY, 1997, 202 (02) : 447 - 452
  • [5] Iterative image warping technique for temporal subtraction of sequential chest radiographs to detect interval change
    Ishida, T
    Katsuragawa, S
    Nakamura, K
    MacMahon, H
    Doi, K
    [J]. MEDICAL PHYSICS, 1999, 26 (07) : 1320 - 1329
  • [6] Application of temporal subtraction for detection of interval changes on chest radiographs: Improvement of subtraction images using automated initial image matching
    Ishida, T
    Ashizawa, K
    Engelmann, R
    Katsuragawa, S
    MacMahon, H
    Doi, K
    [J]. JOURNAL OF DIGITAL IMAGING, 1999, 12 (02) : 77 - 86
  • [7] JAIN AK, 1989, FUNDAMENTALS DIGITAL, P253
  • [8] DIGITAL IMAGE SUBTRACTION OF TEMPORALLY SEQUENTIAL CHEST IMAGES FOR DETECTION OF INTERVAL CHANGE
    KANO, A
    DOI, K
    MACMAHON, H
    HASSELL, DD
    GIGER, ML
    [J]. MEDICAL PHYSICS, 1994, 21 (03) : 453 - 461
  • [9] Contralateral subtraction: A novel technique for detection of asymmetric abnormalities on digital chest radiographs
    Li, Q
    Katsuragawa, S
    Ishida, T
    Yoshida, H
    Tsukuda, S
    MacMahon, H
    Doi, K
    [J]. MEDICAL PHYSICS, 2000, 27 (01) : 47 - 55
  • [10] IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY - AUTOMATED DELINEATION OF POSTERIOR RIBS IN CHEST IMAGES
    SANADA, S
    DOI, K
    MACMAHON, H
    [J]. MEDICAL PHYSICS, 1991, 18 (05) : 964 - 971