Comparability of pulse oximeters used in sleep medicine for the screening of OSA

被引:27
作者
Boehning, N. [1 ,2 ]
Schultheiss, B. [3 ]
Eilers, S. [3 ]
Penzel, T. [4 ]
Boehning, W. [5 ]
Schmittendorf, E. [3 ]
机构
[1] iDoc Inst Telemed, D-14467 Potsdam, Germany
[2] Gesundheitskommunikat GmbH & Co KG, D-14467 Potsdam, Germany
[3] Univ Appl Sci Wilhelmshaven Oldenburg Elsfleth, Dept Engn, D-26389 Wilhelmshaven, Germany
[4] Charite, Interdisciplinary Ctr Sleep Med, D-10117 Berlin, Germany
[5] Karl Hansen Klin Sleep Med Ctr, D-33175 Bad Lippspringe, Germany
关键词
sleep apnea screening; pulse oximetry; reproducibility; signal processing; APNEA; POLYSOMNOGRAPHY; DIAGNOSIS; EPIDEMIOLOGY;
D O I
10.1088/0967-3334/31/7/001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Obstructive sleep apnea syndrome (OSA) is a frequent clinical picture. It is characterized by repetitive respiratory arrest with a consecutive decrease in arterial oxygen saturation (SaO(2)). In clinical practice, the number of desaturations per hour, oxygen desaturation index (ODI), is used as an important diagnostic criterion. Medical literature, however, mentions different threshold values that are defined as pathological. By means of systematic comparative measurements, the study presented here will examine to what extent the diagnosis and the quantification of OSA severity are affected by the device-specific measurement technique, thus impacting the predictive value of nighttime pulse oximetry in outpatient OSA screening. Different pulse oximeters commonly used in clinical practice were analyzed comparatively regarding technical parameters, temporal dynamics and the reproducibility of measuring results. The measurements were executed simultaneously and time synchronized in a reference group of five test subjects (four males, one female, average age 33.0 +/- 9.4 years), in a group of five patients (all males, average age 51.8 +/- 18.4 years) and using a simulator (pulse oximeter simulator index 2). All devices underestimate the simulator's predetermined oxygen desaturation of 10%. The dispersion of values is high. The device-specific characteristics have a significant influence on the collected data. The fundamental weakness of the systems lies in the reproducibility of measuring results (this only seems adequate at a signal resolution in steps of 0.1%) as well as the differing temporal dynamics. In the synchronous use of different systems on patients for the purpose of a direct comparison of devices, the dispersion of values is serious, reaching a fluctuation range of up to factor 1.42. In measuring dynamic events (apneas), different pulse oximeters do not record identical values. This is due to the different internal signal processing of the devices. Without prior knowledge of the pulse oximeter used and the chosen device settings, meaningful interpretation of the measured desaturations is, therefore, ambiguous. Accordingly, different devices require different threshold values in determining the ODI. Standardized technical parameters and the standardization of signal processing are imperative for outpatient screening of sleep-related breathing disorders (SRBD) via pulse oximetry.
引用
收藏
页码:875 / 888
页数:14
相关论文
共 32 条
[11]  
Iber C., 2007, AASM MANUAL SCORING
[12]  
Ip MS., 2002, AM J RESP CRIT CARE, V165, P562
[13]   Obstructive Sleep Apnea and Cardiovascular Disease [J].
Kato, Masahiko ;
Adachi, Taro ;
Koshino, Yuki ;
Somers, Virend K. .
CIRCULATION JOURNAL, 2009, 73 (08) :1363-1370
[14]   Comparison of home oximetry monitoring with laboratory polysomnography in children [J].
Kirk, VG ;
Bohn, SG ;
Flemons, WW ;
Remmers, JE .
CHEST, 2003, 124 (05) :1702-1708
[15]   Prediction of the apnea-hypopnea index from overnight pulse oximetry [J].
Magalang, UJ ;
Dmochowski, J ;
Veeramachaneni, S ;
Draw, A ;
Mador, MJ ;
El-Solh, A ;
Grant, BJB .
CHEST, 2003, 124 (05) :1694-1701
[16]  
PENZEL T, 1993, EEG-EMG-Z ELEK ELEKT, V24, P65
[17]   DOES OXIMETRY CONTRIBUTE TO THE DETECTION OF APNEIC EVENTS - MATHEMATICAL-PROCESSING OF THE SAO2 SIGNAL [J].
PEPIN, JL ;
LEVY, P ;
LEPAULLE, B ;
BRAMBILLA, C ;
GUILLEMINAULT, C .
CHEST, 1991, 99 (05) :1151-1157
[18]   Prospective study of the association between sleep-disordered breathing and hypertension [J].
Peppard, PE ;
Young, T ;
Palta, M ;
Skatrud, J .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (19) :1378-1384
[19]  
PODSZUS T, 2009, SOMNOLOGIE, V13, P113
[20]  
Punjabi Naresh M, 2008, Proc Am Thorac Soc, V5, P136, DOI 10.1513/pats.200709-155MG