Doorway Flows Induced by the Combined Effects of Natural and Forced Ventilation in Case of Multi-compartments Large-Scale Fire Experiments

被引:8
作者
Pretrel, Hugues [1 ]
Koched, Amine [1 ]
Audouin, Laurent [1 ]
机构
[1] Ctr Etud Nucl Cadarache, Lab Commun ETiC, PSN RES SA2I, IRSN, BP3, F-13115 St Paul Les Durance, France
关键词
Compartment fires; Smoke; Doorway; Mechanical ventilation; Buoyancy; Pressure; AIR-FLOW; SIMULATION; SCENARIO;
D O I
10.1007/s10694-015-0524-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper deals with the combined effects of fire and mechanical ventilation on the bi-directional flow occurring at a doorway for a fire scenario involving a three-compartment assembly. Based on large-scale fire tests, the analysis focused on three issues: the velocity profiles at the doorway, the location of the neutral plane, and the inflow and outflow rates entering and leaving the fire compartment. The combined effect of fire and mechanical ventilation leads to different flow regimes depending on whether the smoke outflow (or the fresh air inflow) and the forced ventilation are directed in the same direction or in opposite directions. The theoretical description based on the Bernoulli approach for natural convection flow is applied in case of the combined effect of buoyancy and inertia. Five configurations are identified: one-directional flow of smoke, bi-directional flow with upper smoke flow as dominant, natural convection case with equal smoke and fresh air flows, bi-directional flow with lower fresh air flow as dominant, and one-directional flow with only fresh air flow. These regimes are observed experimentally and clearly defined theoretically. A satisfactory agreement is obtained between the theory and the experiments. This approach permits identifying the critical conditions under which one-directional flow is encountered at the doorway.
引用
收藏
页码:489 / 514
页数:26
相关论文
共 28 条
  • [1] Audouin L, 1999, INT S FIR SAF SCI
  • [2] Beyler C, 2006, P 3 INT S INT ASS FI, P291, DOI DOI 10.3801/IAFSS.FSS.3-291
  • [3] A comparison of gas velocity measurements in a full-scale enclosure fire
    Bryant, Rodney A.
    [J]. FIRE SAFETY JOURNAL, 2009, 44 (05) : 793 - 800
  • [4] Correlation equations on fire-induced air flow rates through doorway derived by large eddy simulation
    Chow, WK
    Zou, GW
    [J]. BUILDING AND ENVIRONMENT, 2005, 40 (07) : 897 - 906
  • [5] Investigation of Sprinkler Sprays on Fire Induced Doorway Flows
    Crocker, Jeremiah P.
    Rangwala, Ali S.
    Dembsey, Nicholas A.
    LeBlanc, David J.
    [J]. FIRE TECHNOLOGY, 2010, 46 (02) : 347 - 362
  • [6] THE HYDRAULICS OF DOORWAY EXCHANGE FLOWS
    DALZIEL, SB
    LANESERFF, GF
    [J]. BUILDING AND ENVIRONMENT, 1991, 26 (02) : 121 - 135
  • [7] Karlsson B., 2000, Enclosure Fire Dynamics
  • [8] Experimental determination of the discharge flow coefficient at a doorway for fire induced flow in natural and mixed convection
    Koched, A.
    Pretrel, H.
    Vauquelin, O.
    Audouin, L.
    [J]. FIRE AND MATERIALS, 2016, 40 (01) : 114 - 128
  • [9] Le Saux W., 2008, FIRE SAFETY SCI, V9, P943, DOI [10.3801/IAFSS.FSS.9-943, DOI 10.3801/IAFSS.FSS.9-943]
  • [10] Lidwell OM, 1997, J HYG, V79, P141, DOI [10.1017/S0022172400052931, DOI 10.1017/S0022172400052931]