Study on the Degradation Mechanism of the Proton Exchange Membrane Fuel Cell Based on a Constant Voltage Cold Start Mode

被引:9
作者
Yang, Yanbo [1 ]
Ma, Tiancai [1 ]
Pei, Fenglai [2 ]
Lin, Weikang [1 ]
Wang, Kai [1 ]
Du, Boyu [1 ]
机构
[1] Tongji Univ, Clean Energy Automot Engn Ctr, Sch Automot Studies, 4800 Caoan Rd, Shanghai 201804, Peoples R China
[2] Shanghai Motor Vehicle Inspect Certificat & Tech, 68 South Yutian Rd, Shanghai 201804, Peoples R China
基金
中国国家自然科学基金;
关键词
proton exchange membrane fuel cell; cold start; constant voltage mode; degradation; DESIGN PARAMETERS; PERFORMANCE; TEMPERATURE; STRATEGY; BEHAVIOR; PEFC; OPERATION; HYDROGEN; LAYERS;
D O I
10.1115/1.4052534
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The constant voltage cold start of the proton exchange membrane fuel cell (PEMFC) is usually operated at a low start-voltage in order to ensure high heat generation, which can shorten the process of the PEMFC cold start. However, the effect of constant voltage cold start on the durability of PEMFC is still unclear. Thus, in this work, the PEMFC is tested repeatedly at a low start-voltage to simulate its actual operating state in the vehicle. Then, the effect of the PEMFC durability under constant voltage cold start is investigated by polarization curve, cyclic voltammetry, electrochemical impedance spectroscopy, transmission electron microscope, and ion chromatography. After the repeatedly cold start, the output performance of the PEMFC decreases significantly. According to the characterization results, the degradation mechanism of the PEMFC at the constant voltage cold start is demonstrated to be that the PEMFC start-up repeatedly at low start-voltage leads to the decomposition of membrane polymer structure and promotes the crossover of H-2. Meanwhile, the PEMFC start-up repeatedly at low start-voltage also leads to the agglomeration of catalysts, which reduces the active area of catalysts and ultimately results in the degradation of fuel cell performance. Above all, this study proves that the durability of PEMFC can be shortened by the constant voltage cold start at 0.1 V, which provides a reference for the development of the PEMFC cold start control strategy.
引用
收藏
页数:8
相关论文
共 50 条
[31]   Statistical investigation of the most influent parameters on the cold start of Proton Exchange Membrane Fuel Cell [J].
Gantzer, Matteo ;
Giurgea, Stefan ;
Hissel, Daniel ;
Yousfi-Steiner, Nadia .
2024 IEEE VEHICLE POWER AND PROPULSION CONFERENCE, VPPC 2024, 2024,
[32]   Simultaneous measurement of current and temperature distributions in a proton exchange membrane fuel cell during cold start processes [J].
Jiao, Kui ;
Alaefour, Ibrahim E. ;
Karimi, Gholamreza ;
Li, Xianguo .
ELECTROCHIMICA ACTA, 2011, 56 (08) :2967-2982
[33]   A Review on Cold Start of Proton Exchange Membrane Fuel Cells [J].
Wan, Zhongmin ;
Chang, Huawei ;
Shu, Shuiming ;
Wang, Yongxiang ;
Tang, Haolin .
ENERGIES, 2014, 7 (05) :3179-3203
[34]   Cold-start method for proton-exchange membrane fuel cells based on locally heating the cathode [J].
Li, Linjun ;
Wang, Shixue ;
Yue, Like ;
Wang, Guozhuo .
APPLIED ENERGY, 2019, 254
[35]   Real time adaptive efficient cold start strategy for proton exchange membrane fuel cells [J].
Amamou, A. ;
Kandidayeni, M. ;
Boulon, L. ;
Kelouwani, S. .
APPLIED ENERGY, 2018, 216 :21-30
[36]   Rapid cold start of proton exchange membrane fuel cells by the printed circuit board technology [J].
Lin, Rui ;
Weng, Yuanming ;
Lin, Xuwei ;
Xiong, Feng .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (32) :18369-18378
[37]   Comparison of self cold start strategies of automotive Proton Exchange Membrane Fuel Cell [J].
Amamou, A. ;
Boulon, L. ;
Kelouwani, S. .
2018 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2018, :904-908
[38]   Characteristics of proton exchange membrane fuel cells cold start with silica in cathode catalyst layers [J].
Miao, Zhili ;
Yu, Hongmei ;
Song, Wei ;
Hao, Lixing ;
Shao, Zhigang ;
Shen, Qiang ;
Hou, Junbo ;
Yi, Baolian .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (11) :5552-5557
[39]   The voltage uniformity analysis of high-power proton exchange membrane fuel cell stack during cold start [J].
Lv, Ping ;
Wu, Siyuan ;
Hou, Ben ;
Sun, Xin ;
Wang, Zixuan ;
Liu, Xueting ;
Li, Guangwei ;
Han, Meng ;
Jiao, Kui ;
Du, Qing ;
Xing, Danmin .
APPLIED ENERGY, 2025, 393
[40]   Ultralow degradation cold start of proton exchange membrane fuel cell with alternating hydrogen pump method [J].
Shi, Wenbo ;
Li, Dewei ;
Niu, Kai ;
Yang, Ruoxi ;
Xu, Haosen ;
Zhang, Jianbo .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 86 :404-413