Study on the Degradation Mechanism of the Proton Exchange Membrane Fuel Cell Based on a Constant Voltage Cold Start Mode

被引:6
作者
Yang, Yanbo [1 ]
Ma, Tiancai [1 ]
Pei, Fenglai [2 ]
Lin, Weikang [1 ]
Wang, Kai [1 ]
Du, Boyu [1 ]
机构
[1] Tongji Univ, Clean Energy Automot Engn Ctr, Sch Automot Studies, 4800 Caoan Rd, Shanghai 201804, Peoples R China
[2] Shanghai Motor Vehicle Inspect Certificat & Tech, 68 South Yutian Rd, Shanghai 201804, Peoples R China
基金
中国国家自然科学基金;
关键词
proton exchange membrane fuel cell; cold start; constant voltage mode; degradation; DESIGN PARAMETERS; PERFORMANCE; TEMPERATURE; STRATEGY; BEHAVIOR; PEFC; OPERATION; HYDROGEN; LAYERS;
D O I
10.1115/1.4052534
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The constant voltage cold start of the proton exchange membrane fuel cell (PEMFC) is usually operated at a low start-voltage in order to ensure high heat generation, which can shorten the process of the PEMFC cold start. However, the effect of constant voltage cold start on the durability of PEMFC is still unclear. Thus, in this work, the PEMFC is tested repeatedly at a low start-voltage to simulate its actual operating state in the vehicle. Then, the effect of the PEMFC durability under constant voltage cold start is investigated by polarization curve, cyclic voltammetry, electrochemical impedance spectroscopy, transmission electron microscope, and ion chromatography. After the repeatedly cold start, the output performance of the PEMFC decreases significantly. According to the characterization results, the degradation mechanism of the PEMFC at the constant voltage cold start is demonstrated to be that the PEMFC start-up repeatedly at low start-voltage leads to the decomposition of membrane polymer structure and promotes the crossover of H-2. Meanwhile, the PEMFC start-up repeatedly at low start-voltage also leads to the agglomeration of catalysts, which reduces the active area of catalysts and ultimately results in the degradation of fuel cell performance. Above all, this study proves that the durability of PEMFC can be shortened by the constant voltage cold start at 0.1 V, which provides a reference for the development of the PEMFC cold start control strategy.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Cold start characteristics of proton exchange membrane fuel cells
    Jiao, Kui
    Alaefour, Ibrahim E.
    Karimi, Gholamreza
    Li, Xianguo
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (18) : 11832 - 11845
  • [22] Numerical investigations of assisted heating cold start strategies for proton exchange membrane fuel cell systems
    Yang, Zirong
    Jiao, Kui
    Wu, Kangcheng
    Shi, Weilong
    Jiang, Shangfeng
    Zhang, Longhai
    Du, Qing
    ENERGY, 2021, 222
  • [23] Theoretical analysis on cold start process of proton exchange membrane fuel cell with different flow fields based on the coupling of redox reaction and dynamic response of porous materials
    Pan, Chengjie
    Li, Ding
    Liang, Ke
    Meng, Xianpan
    Pan, Mingzhang
    ENERGY CONVERSION AND MANAGEMENT, 2022, 253
  • [24] Study on Fast Cold Start-Up Method of Proton Exchange Membrane Fuel Cell Based on Electric Heating Technology
    Jiang, Wei
    Song, Ke
    Zheng, Bailin
    Xu, Yongchuan
    Fang, Ruoshi
    ENERGIES, 2020, 13 (17)
  • [25] Study on internal dynamic response during cold start of proton exchange membrane fuel cell with parallel and serpentine flow fields
    Yang, Xiaokang
    Meng, Xiangchao
    Sun, Jiaqi
    Song, Wei
    Sun, Shucheng
    Shao, Zhigang
    JOURNAL OF POWER SOURCES, 2023, 561
  • [26] Modeling of assisted cold start processes with anode catalytic hydrogen-oxygen reaction in proton exchange membrane fuel cell
    Guo, Qian
    Luo, Yueqi
    Jiao, Kui
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (02) : 1004 - 1015
  • [27] Maximum power tracking-based adaptive cold start strategy for proton exchange membrane fuel cell
    Pan, Mingzhang
    Li, Ding
    Pan, Chengjie
    Liang, Lu
    ENERGY CONVERSION AND MANAGEMENT, 2022, 273
  • [28] Influence of cathode channel blockages on the cold start performance of proton exchange membrane fuel cell: A numerical study
    Dafalla, Ahmed Mohmed
    Wei, Lin
    Liao, Zihao
    Guo, Jian
    Jiang, Fangming
    ENERGY, 2023, 263
  • [29] Simultaneous measurement of current and temperature distributions in a proton exchange membrane fuel cell during cold start processes
    Jiao, Kui
    Alaefour, Ibrahim E.
    Karimi, Gholamreza
    Li, Xianguo
    ELECTROCHIMICA ACTA, 2011, 56 (08) : 2967 - 2982
  • [30] A Review on Cold Start of Proton Exchange Membrane Fuel Cells
    Wan, Zhongmin
    Chang, Huawei
    Shu, Shuiming
    Wang, Yongxiang
    Tang, Haolin
    ENERGIES, 2014, 7 (05): : 3179 - 3203