Sorbent-based sampling methods for volatile and semi-volatile organic compounds in air. Part 2. Sorbent selection and other aspects of optimizing air monitoring methods

被引:141
作者
Woolfenden, Elizabeth [1 ]
机构
[1] Markes Int Ltd, Llantrisant CF27 8XL, RCT, England
关键词
Air monitoring; Sorbent tubes; Sorbent traps; VOCs; SVOCs; Volatile organic chemicals; Semi-volatile organic chemicals; Thermal desorption; SOLID ADSORBENTS;
D O I
10.1016/j.chroma.2010.01.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Sorbent tubes/traps are widely used in combination with gas chromatographic (GC) analytical methods to monitor the vapour-phase fraction of organic compounds in air. Applications range from atmospheric research and ambient air monitoring (indoor and outdoor) to occupational hygiene (personal exposure assessment) and measuring chemical emission levels. Part 1 of this paper reviewed the main sorbent-based air sampling strategies including active (pumped) tube monitoring, diffusive (passive) sampling onto sorbent tubes/cartridges plus sorbent trapping/focusing of whole air samples that are either collected in containers (such as canisters or bags) or monitored online. Options for subsequent extraction and transfer to GC(MS) analysis were also summarised and the trend to thermal desorption (TD)-based methods and away from solvent extraction was explained. As a result of this trend, demand for TD-compatible sorbents (alternatives to traditional charcoal) is growing. Part 2 of this paper therefore continues with a summary of TO-compatible sorbents, their respective advantages and limitations and considerations for sorbent selection. Other analytical considerations for optimizing sorbent-based air monitoring methods are also discussed together with recent technical developments and sampling accessories which have extended the application range of sorbent trapping technology generally. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2685 / 2694
页数:10
相关论文
共 34 条
[1]  
*AGBB DLBT, 2000 HLTH REL EV VOL, P3
[2]  
*ASTM WK, 22044 ASTM WK
[3]   Gas phase detection of explosives such as 2,4,6-trinitrotoluene by molecularly imprinted polymers [J].
Bunte, Gudrun ;
Huerttlen, Juergen ;
Pontius, Heike ;
Hartlieb, Kerstin ;
Krause, Horst .
ANALYTICA CHIMICA ACTA, 2007, 591 (01) :49-56
[4]   GAS-CHROMATOGRAPHIC EVALUATION OF THE ORGANIC-COMPONENTS PRESENT IN THE ATMOSPHERE AT TRACE LEVELS WITH THE AID OF CARBOPACK-B FOR PRECONCENTRATION OF THE SAMPLE [J].
CICCIOLI, P ;
BRANCALEONI, E ;
CECINATO, A ;
DIPALO, C ;
BRACHETTI, A ;
LIBERTI, A .
JOURNAL OF CHROMATOGRAPHY, 1986, 351 (03) :433-449
[5]   EVALUATION OF ORGANIC POLLUTANTS IN OPEN AIR AND ATMOSPHERES IN INDUSTRIAL SITES USING GRAPHITIZED CARBON-BLACK TRAPS AND GAS CHROMATOGRAPHIC-MASS SPECTROMETRIC ANALYSIS WITH SPECIFIC DETECTORS [J].
CICCIOLI, P ;
BERTONI, G ;
BRANCALEONI, E ;
FRATARCANGELI, R ;
BRUNER, F .
JOURNAL OF CHROMATOGRAPHY, 1976, 126 (NOV3) :757-770
[6]   IDENTIFICATION AND DETERMINATION OF BIOGENIC AND ANTHROPOGENIC VOLATILE ORGANIC-COMPOUNDS IN FOREST AREAS OF NORTHERN AND SOUTHERN EUROPE AND A REMOTE SITE OF THE HIMALAYA REGION BY HIGH-RESOLUTION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
CICCIOLI, P ;
BRANCALEONI, E ;
CECINATO, A ;
SPARAPANI, R ;
FRATTONI, M .
JOURNAL OF CHROMATOGRAPHY, 1993, 643 (1-2) :55-69
[7]  
*COLL HIGH PERF SC, 2004, REF SPEC EN RES EFF
[8]   A novel device for capturing breath samples for solvent analysis [J].
Dyne, D ;
Cocker, J ;
Wilson, HK .
SCIENCE OF THE TOTAL ENVIRONMENT, 1997, 199 (1-2) :83-89
[9]  
*EC CONSTR PROD RE, REV TEXT AD MAY 2009
[10]  
*ECHA, 2008, GUID REQ SUBST ART