Revisited position arithmetics for LaBr3:Ce continuous crystals

被引:26
作者
Pani, R. [1 ]
Vittorini, F. [1 ]
Cinti, M. N. [1 ]
Bennati, P. [2 ]
Pellegrini, R. [1 ]
Ridolfi, S. [1 ]
Scafe, R. [3 ]
Lo Meo, S. [4 ,5 ]
Mattioli, M. [6 ]
Navarria, F. L. [4 ,5 ]
Moschini, G. [7 ,8 ]
Fabbri, A. [2 ]
D'Abramo, E. [2 ]
Cencelli, V. Orsolini [9 ]
Sacco, D. [10 ]
机构
[1] Univ Roma La Sapienza, Expt Med Dpt, I-00161 Rome, Italy
[2] Univ Rome III, EDEMOM PhD Sch Microelect, Rome, Italy
[3] ENEA, Rome, Italy
[4] INFN Bologna, Bologna, Italy
[5] Univ Bologna, Alma Mater Studiorum, Phys Dpt, Bologna, Italy
[6] Univ Roma La Sapienza, Phys Dpt, I-00161 Rome, Italy
[7] Univ Padua, Phys Dpt, Padua, Italy
[8] Ist Nazl Fis Nucl, Lab Nazl Legnaro, Padua, Italy
[9] Roma III Univ Rome, Dept Elect Engn, Ist Nazl Fis Nucl, Rome, Italy
[10] ISPESL, Rome, Italy
关键词
D O I
10.1016/j.nuclphysbps.2009.10.109
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
The development of the molecular imaging technique based on radiopharmaceuticals is requiring sophisticated devices with sub-millimeter spatial resolution and high detection efficiency. Recently, in the field of scintillation gamma camera, it has been demonstrated that continuous crystals may improve spatial resolution with respect to the use of scintillation arrays. In this work we propose a new algorithm that improves spatial resolution. It calculates the position from a single scintillation event by squaring the charge collected on a multi-anodes photomultiplier tube (MA-PMT). It is able to remove the position linearity distortion due to the light reflections and the truncations at the crystal edge. We present measurements from a compact gamma camera based on a 51 mm x 51 turn x 4.0 mm LaBra(3):Ce continuous scintillation crystal, coupled to a MA-PMT Hamamatsu H8500. The results show a strong improvement in spatial resolution and confirm the high potential in using of LaBr continuous crystal for molecular imaging applications.
引用
收藏
页码:383 / 386
页数:4
相关论文
共 7 条
[1]   SCINTILLATION CAMERA [J].
ANGER, HO .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1958, 29 (01) :27-33
[2]   AN INVESTIGATION OF PARAMETERS IN SCINTILLATION CAMERA DESIGN [J].
BAKER, RG ;
SCRIMGER, JW .
PHYSICS IN MEDICINE AND BIOLOGY, 1967, 12 (01) :51-+
[3]   Multichannel Readout Electronics for Flat Panel PSPMT [J].
D'Abramo, Enrico ;
de Notaristefani, Francesco ;
Cencelli, Valentino Orsolini .
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, :3072-3075
[4]   Investigation of a continuous crystal PSAPD-based gamma camera [J].
Despres, Philippe ;
Barber, William C. ;
Funk, Tobias ;
McClish, Mickel ;
Shah, Kanai S. ;
Hasegawa, Bruce H. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) :1643-1649
[5]  
MEO L, 2008, NUCL SCI S 2008 NSS, P4964
[6]  
Pani R, 2005, IEEE NUCL SCI CONF R, P2061
[7]   DESIGN OF AN EFFICIENT POSITION-SENSITIVE GAMMA-RAY DETECTOR FOR NUCLEAR-MEDICINE [J].
ROGERS, JG ;
SAYLOR, DP ;
HARROP, R ;
YAO, XG ;
LEITAO, CVM ;
PATE, BD .
PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (10) :1061-1090