Pulse pressure variation and pleth variability index as predictors of fluid responsiveness in patients undergoing spinal surgery in the prone position

被引:18
作者
Kim, Do-Hyeong [1 ]
Shin, Seokyung [1 ]
Kim, Ji Young [1 ]
Kim, Seung Hyun [2 ]
Jo, Minju [2 ]
Choi, Yong Seon [1 ]
机构
[1] Yonsei Univ, Anesthesia & Pain Res Inst, Dept Anesthesiol & Pain Med, Coll Med, 50-1 Yonsei Ro, Seoul 03722, South Korea
[2] Yonsei Univ, Coll Med, Dept Anesthesiol & Pain Med, Seoul, South Korea
关键词
fluid therapy; intraoperative monitoring; prone position; stroke volume; CRITICALLY-ILL PATIENTS; TRANSESOPHAGEAL DOPPLER; RESPIRATORY VARIATIONS; HEMODYNAMIC-RESPONSE; ESOPHAGEAL DOPPLER; CARDIAC-OUTPUT; ZONE APPROACH; GREY ZONE; VOLUME; ANESTHESIA;
D O I
10.2147/TCRM.S170395
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: This study investigated the ability of pulse pressure variation (PPV) and pleth variability index (PVI) to predict fluid responsiveness of patients undergoing spinal surgery in the prone position. Patients and methods: A total of 53 patients undergoing posterior lumbar spinal fusion in the prone position on a Jackson table were studied. PPV, PVI, and hemodynamic and respiratory variables were measured both before and after the administration of 6 mL/kg colloid in both the supine and prone positions. Fluid responsiveness was defined as a 15% or greater increase in stroke volume index, as assessed by esophageal Doppler monitor after fluid loading. Results: In the supine position, 40 patients were responders. The areas under the receiver operating characteristic (ROC) curves for PPV and PVI were 0.783 [95% CI 0.648-0.884, P<0.001] and 0.814 (95% CI 0.684-0.908, P<0.001), respectively. The optimal cut-off values of PPV and PVI were 10% (sensitivity 75%, specificity 62%) and 8% (sensitivity 78%, specificity 77%), respectively. In the prone position, 27 patients were responders. The areas under the ROC curves for PPV and PVI were 0.781 (95% CI 0.646-0.883, P<0.001) and 0.756 (95% CI 0.618-0.863, P<0.001), respectively. The optimal cut-off values of PPV and PVI were 7% (sensitivity 82%, specificity 62%) and 8% (sensitivity 67%, specificity 69%), respectively. Conclusion: Both PPV and PVI were able to predict fluid responsiveness; their predictive abilities were maintained in the prone position.
引用
收藏
页码:1175 / 1183
页数:9
相关论文
共 37 条
[1]   Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery [J].
Biais, M. ;
Bernard, O. ;
Ha, J. C. ;
Degryse, C. ;
Sztark, F. .
BRITISH JOURNAL OF ANAESTHESIA, 2010, 104 (04) :407-413
[2]   Clinical relevance of pulse pressure variations for predicting fluid responsiveness in mechanically ventilated intensive care unit patients: the grey zone approach [J].
Biais, Matthieu ;
Ehrmann, Stephan ;
Mari, Arnaud ;
Conte, Benjamin ;
Mahjoub, Yazine ;
Desebbe, Olivier ;
Pottecher, Julien ;
Lakhal, Karim ;
Benzekri-Lefevre, Dalila ;
Molinari, Nicolas ;
Boulain, Thierry ;
Lefrant, Jean-Yves ;
Muller, Laurent .
CRITICAL CARE, 2014, 18 (06)
[3]   Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index [J].
Broch, O. ;
Bein, B. ;
Gruenewald, M. ;
Hoecker, J. ;
Schoettler, J. ;
Meybohm, P. ;
Steinfath, M. ;
Renner, J. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (06) :686-693
[4]   Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre [J].
Cannesson, M. ;
Desebbe, O. ;
Rosamel, P. ;
Delannoy, B. ;
Robin, J. ;
Bastien, O. ;
Lehot, J. -J. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (02) :200-206
[5]   The ability of a novel algorithm for automatic estimation of the respiratory variations, in arterial pulse pressure to monitor fluid responsiveness in the operating room [J].
Cannesson, Maxime ;
Slieker, Juliette ;
Desebbe, Olivier ;
Bauer, Christian ;
Chiari, Pascal ;
Henaine, Roland ;
Lehot, Jean-Jacques .
ANESTHESIA AND ANALGESIA, 2008, 106 (04) :1195-1200
[6]   Assessing the Diagnostic Accuracy of Pulse Pressure Variations for the Prediction of Fluid Responsiveness A "Gray Zone" Approach [J].
Cannesson, Maxime ;
Le Manach, Yannick ;
Hofer, Christoph K. ;
Goarin, Jean Pierre ;
Lehot, Jean-Jacques ;
Vallet, Benoit ;
Tavernier, Benoit .
ANESTHESIOLOGY, 2011, 115 (02) :231-241
[7]   An update on the prone position: Continuing Professional Development [J].
Chui, Jason ;
Craen, Rosemary Ann .
CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2016, 63 (06) :737-767
[8]   A grey zone for quantitative diagnostic and screening tests [J].
Coste, J ;
Pouchot, J .
INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 2003, 32 (02) :304-313
[9]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[10]   Effect of prone positioning systems on hemodynamic and cardiac function during lumbar spine surgery: An echocardiographic study [J].
Dharmavaram, Sreenivasa ;
Jellish, W. Scott ;
Nockels, Russ P. ;
Shea, John ;
Mehmood, Rashid ;
Ghanayem, Alex ;
Kleinman, Bruce ;
Jacobs, William .
SPINE, 2006, 31 (12) :1388-1393