Low-power, noninvasive measurement system for wearable ballistocardiography in sitting and standing positions

被引:24
作者
Liu, Mengxing [1 ,2 ,3 ]
Jiang, Feng [1 ]
Jiang, He [1 ]
Ye, Shuming [1 ]
Chen, Hang [1 ,2 ,3 ]
机构
[1] Zhejiang Univ, Coll Biomed Engn & Instrument Sci, Hangzhou 310027, Zhejiang, Peoples R China
[2] Zhejiang Univ, Key Lab Biomed Engn, Minist Educ, Hangzhou 310027, Zhejiang, Peoples R China
[3] Zhejiang Prov Key Lab Cardiocerebral Vasc Detect, Hangzhou 310027, Zhejiang, Peoples R China
关键词
Ballistocardiography; Non-invasive measurement; Low power consumption; Electrostatic discharge; Wearable device; HEART-RATE;
D O I
10.1016/j.compind.2017.05.005
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Ballistocardiography (BCG), the noninvasive measurement of the reaction forces of the body to the cardiac ejection of blood, is one of few methods available for unobtrusively assessing the mechanical aspects of cardiovascular health outside clinical settings. In this study, two sizes of piezoelectric film sensors were installed into the seat cushion of a chair and the foot insole, respectively, to acquire local BCG signals in sitting and standing positions. The design and engineering implementation of the signal processing circuit and data transmission system are discussed below. Although wearable BCG measurement devices have been extensively researched to date, to the authors' knowledge, they have never been tested in regards to power consumption and electrostatic discharge (ESD) immunity. In this work, comprehensive experiments were conducted to show the low power consumption and high reliability of the proposed system. The shapes and the amplitudes of measured signals were examined in detail. The results suggest that the proposed system can feasibly and reliably be used to continuously record and evaluate cardiovascular changes occurring throughout an individual's daily life. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:24 / 32
页数:9
相关论文
共 24 条
  • [1] Exploring Neuro-Physiological Correlates of Drivers' Mental Fatigue Caused by Sleep Deprivation Using Simultaneous EEG, ECG, and fNIRS Data
    Ahn, Sangtae
    Nguyen, Thien
    Jang, Hyojung
    Kim, Jae G.
    Jun, Sung C.
    [J]. FRONTIERS IN HUMAN NEUROSCIENCE, 2016, 10
  • [2] Ballistocardiography in sitting and horizontal positions
    Alametsa, J.
    Viik, J.
    Alakare, J.
    Varri, A.
    Palomaki, A.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2008, 29 (09) : 1071 - 1087
  • [3] Altman, 2010, INT J NURS STUD, V47
  • [4] An algorithm for beat-to-beat heart rate detection from the BCG based on the continuous spline wavelet transform
    Alvarado-Serrano, Carlos
    Samuel Luna-Lozano, Pablo
    Pallas-Areny, Ramon
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2016, 27 : 96 - 102
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] Adaptive Beat-to-Beat Heart Rate Estimation in Ballistocardiograms
    Brueser, Christoph
    Stadlthanner, Kurt
    de Waele, Stijn
    Leonhardt, Steffen
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (05): : 778 - 786
  • [7] Chung GS, 2007, P ANN INT IEEE EMBS, P2357
  • [8] Gieratowski J., 2013, PHYSIOL MEAS, V34, P123
  • [9] Non-invasive cardiac output trending during exercise recovery on a bathroom-scale-based ballistocardiograph
    Inan, O. T.
    Etemadi, M.
    Paloma, A.
    Giovangrandi, L.
    Kovacs, G. T. A.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2009, 30 (03) : 261 - 274
  • [10] An Electromechanical Film Sensor Based Wireless Ballistocardiographic Chair: Implementation and Performance
    Junnila, Sakari
    Akhbardeh, Alireza
    Varri, Alpo
    [J]. JOURNAL OF SIGNAL PROCESSING SYSTEMS FOR SIGNAL IMAGE AND VIDEO TECHNOLOGY, 2009, 57 (03): : 305 - 320