Accuracy of IOL Power Calculation Using the New Carlevale Sutureless Scleral Fixation Posterior Chamber IOL

被引:12
|
作者
Vaiano, Agostino S. [1 ]
Hoffer, Kenneth J. [2 ,3 ]
Greco, Andrea [1 ]
Greco, Antonio [1 ]
D'Amico, Giovanni [1 ]
Pasqualitto, Valerio [1 ]
Carlevale, Carlo [4 ]
Savini, Giacomo [5 ]
机构
[1] Santa Croce & Carle Hosp, Inst Ophthalmol, Cuneo, Italy
[2] Univ Calif Los Angeles, Stein Eye Inst, Los Angeles, CA USA
[3] St Marys Eye Ctr, Santa Monica, CA USA
[4] Karol Wojtyla Hosp, Rome, Italy
[5] IRCCS GB Bietti Fdn, Rome, Italy
关键词
INTRAOCULAR-LENS IMPLANTATION; REFRACTIVE-OUTCOMES; FORMULA; ABSENCE;
D O I
10.3928/1081597X-20210401-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the refractive outcomes of the new Carlevale foldable sutureless scleral fixation intraocular lens (SSF-IOL) (Soleko in eyes without capsular support. METHODS: This retrospective, single-center, noncomparative interventional case series included 25 consecutive eyes of 25 consecutive patients with either aphakia or lens/IOL dislocation due to capsular or zonular defects. The Hoffer Q, Holladay 1, and SRK/T formulas, which do not need measurements of the anterior chamber depth to predict the IOL position, were used to calculate the IOL power. Constant optimization was performed to zero out the mean prediction error (PE). The main outcome measures were mean PE +/- standard deviation, median absolute error (MedAE), mean absolute error (MAE), and percentage of eyes with a PE within +/- 0.50 and +/- 1.00 diopters (D). RESULTS: Mean axial length was 24.09 +/- 2.09 mm (range: 21.85 to 32.17 mm). No statistically significant differences were found among the three formulas for any parameter. The PE was zero due to constant optimization and its standard deviation ranged between 0.89 and 0.95 D. The MedAE ranged between 0.30 and 0.34 D, whereas the MAE ranged between 0.62 and 0.67 D. The percentage of eyes with a PE within +/- 0.50 D was between 56% and 64% and the percentage of eyes with a PE within +/- 1.00 D was between 69% and 72%. CONCLUSIONS: Reasonably good refractive outcomes can be obtained when implanting SSF-IOLs in eyes with no capsular support, although the accuracy is lower than what is reported for normal in-the-bag IOL implantation.
引用
收藏
页码:472 / 476
页数:5
相关论文
共 50 条
  • [1] Long-term Outcomes and Complications of the New Carlevale Sutureless Scleral Fixation Posterior Chamber IOL
    Vaiano, Agostino S.
    Hoffer, Kenneth J.
    Greco, Antonio
    Greco, Andrea
    D'Amico, Giovanni
    Pasqualitto, Valerio
    Carlevale, Carlo
    Savini, Giacomo
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (02) : 126 - +
  • [2] Sutureless scleral fixation Carlevale IOL: a review on the novel designed lens
    Matteo Mario Carlà
    Francesco Boselli
    Federico Giannuzzi
    Tomaso Caporossi
    Gloria Gambini
    Luigi Mosca
    Alfonso Savastano
    Stanislao Rizzo
    International Ophthalmology, 2023, 43 : 2129 - 2138
  • [3] Sutureless scleral fixation Carlevale IOL: a review on the novel designed lens
    Carla, Matteo Mario
    Boselli, Francesco
    Giannuzzi, Federico
    Caporossi, Tomaso
    Gambini, Gloria
    Mosca, Luigi
    Savastano, Alfonso
    Rizzo, Stanislao
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (06) : 2129 - 2138
  • [4] Efficacy and safety of UT-DSAEK combined with Carlevale's sutureless scleral fixation IOL
    Vaiano, Agostino S.
    Greco, Antonio
    Greco, Andrea
    Toro, Maria E.
    Leto, Marco G.
    Savini, Giacomo
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (06) : 2201 - 2209
  • [5] Two Techniques for Sutureless Intrascleral Posterior Chamber IOL Fixation
    Totan, Yuksel
    Karadag, Remzi
    JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (02) : 90 - 94
  • [6] Transconjunctival Sutureless Haptic Fixation of Posterior Chamber IOL: A Minimally Traumatic Approach for IOL Rescue or Secondary Implantation
    Prasad, Som
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2013, 33 (03): : 657 - 660
  • [7] Trans-scleral plugs fixated IOL: a new paradigm for sutureless scleral fixation
    Barca, Francesco
    Caporossi, Tomaso
    de Angelis, Lorenzo
    Giansanti, Fabrizio
    Savastano, Alfonso
    Di Leo, Laura
    Rizzo, Stanislao
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (05): : 716 - 720
  • [8] Sutureless scleral fixation: comparison between 3-piece IOL and new single-piece foldable IOL
    D'Agostino, Isabella
    Parrulli, Salvatore
    De Angelis, Stefano
    Invernizzi, Alessandro
    Bottoni, Ferdinando
    Staurenghi, Giovanni
    Cereda, Matteo Giuseppe
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (05) : 1365 - 1373
  • [9] Sutureless scleral fixation: comparison between 3-piece IOL and new single-piece foldable IOL
    Isabella D’Agostino
    Salvatore Parrulli
    Stefano De Angelis
    Alessandro Invernizzi
    Ferdinando Bottoni
    Giovanni Staurenghi
    Matteo Giuseppe Cereda
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 1365 - 1373
  • [10] Scleral fixation posterior chamber intraocular lens (IOL): An improved design for easier implantation
    Pannarale, L
    Pannarale, MR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 904 - 904