A fast and direct determination of bisphenol S in thermal paper samples using paper spray ionization mass spectrometry

被引:6
作者
Bernardo, Ricardo Alves [1 ]
Sousa, Jean Carlos Pereira [1 ]
Gallimberti, Matheus [2 ]
Barbosa Junior, Fernando [2 ]
Vaz, Boniek Gontijo [1 ]
Chaves, Andrea Rodrigues [1 ]
机构
[1] Univ Fed Goias, Inst Chem, BR-74690900 Goiania, Go, Brazil
[2] Univ Sao Paulo, Fac Pharmaceut Sci Ribeirao Preto, BR-14040900 Ribeirao Preto, SP, Brazil
关键词
Bisphenol S; Thermal paper; Paper spray ionization; Ambient ionization; Mass spectrometry; LIQUID-LIQUID MICROEXTRACTION; EXPOSURE; PRODUCTS; REPLACEMENTS; ANALOGS;
D O I
10.1007/s11356-021-14603-0
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Concerns about human health regarding the large use of bisphenol A in thermal papers have led to its replacement by bisphenol S. Analyses of bisphenols require several sample pretreatment steps, which are laborious, expensive, and time-consuming. A paper spray ionization mass spectrometry (PSI-MS) was developed to detect and quantify bisphenol S in three different brands of thermal papers commercially available. Parameters such as paper size, and paper position relative to the mass spectrometer inlet were evaluated. The analyses were performed in selected ion monitoring mode on a linear ion trap mass spectrometer. The developed method presented absolute recovery values ranging from 92.2 to 109.04%, accuracy values from -1.2 to 9.0%, and inter assay precision from 1.8 to 5.6% and enabled LOD as low as 5 ng g(-1). The concentration of bisphenol S in all of the three brands of BPA-free thermal papers evaluated ranged from 1.36 to 6.77 mu g g(-1), and the concentrarion of BPA ranged from 6.56 to 16.4 mu g g(-1) in all samples of thermal paper evaluated. The PSI-MS method described here was comparable to the conventional ones, such as liquid chromatography coupled with mass spectrometry and gas chromatography coupled with mass spectrometry described in the literature. The present study proved to be practical, fast, and efficient for the direct determination of bisphenol S in thermal papers. Furthermore, the methodology here described showed to be a promising alternative to replace the classical methods for determination of bisphenol S, due to its simplicity, and no needing of any sample pretreatment.
引用
收藏
页码:57288 / 57296
页数:9
相关论文
共 48 条
[1]   Comparative effects of Bisphenol S and Bisphenol A on the development of female reproductive system in rats; a neonatal exposure study [J].
Ahsan, Nida ;
Ullah, Hizb ;
Ullah, Waheed ;
Jahan, Sarwat .
CHEMOSPHERE, 2018, 197 :336-343
[2]   Ionic liquid based vortex assisted liquid-liquid microextraction combined with liquid chromatography mass spectrometry for the determination of bisphenols in thermal papers with the aid of response surface methodology [J].
Asati, Ankita ;
Satyanarayana, G. N. V. ;
Panchal, Smita ;
Thakur, Ravindra Singh ;
Ansari, Nasreen G. ;
Patel, Devendra K. .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1509 :35-42
[3]   Detection and quantification of traces of bisphenol A and bisphenol S in paper samples using analytical pyrolysis-GC/MS [J].
Becerra, Valentina ;
Odermatt, Juergen .
ANALYST, 2012, 137 (09) :2250-2259
[4]   Bisphenol A alternatives in thermal paper from the Netherlands, Spain, Sweden and Norway. Screening and potential toxicity [J].
Bjornsdotter, Maria K. ;
Jonker, Willem ;
Legradi, Jessica ;
Kool, Jeroen ;
Ballesteros-Gomez, Ana .
SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 601 :210-221
[5]   Bisphenol A and replacements in thermal paper: A review [J].
Bjornsdotter, Maria K. ;
de Boer, Jacob ;
Ballesteros-Gomez, Ana .
CHEMOSPHERE, 2017, 182 :691-706
[6]   Direct analysis in real time accurate mass spectrometry determination of bisphenol A in thermal printing paper [J].
Castro, G. ;
Rodriguez, I ;
Ramil, M. ;
Cela, R. .
TALANTA, 2019, 205
[7]   Rapid Analysis of Bisphenol A and Its Analogues in Food Packaging Products by Paper Spray Ionization Mass Spectrometry [J].
Chen, Shuo ;
Chang, Quanying ;
Yin, Kai ;
He, Qunying ;
Deng, Yongxiu ;
Chen, Bo ;
Liu, Chengbin ;
Wang, Ying ;
Wang, Liping .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2017, 65 (23) :4859-4865
[8]   Synthesis and Developing Properties of Functional Phenolic Polymers for Ecofriendly Thermal Papers [J].
Choi, Kang-Hoon ;
Kwon, Hyun-Jin ;
An, Byeong-Kwan .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2018, 57 (02) :540-547
[9]  
Colletes TC, 2016, ANALYST, V141, P1707, DOI [10.1039/C5AN01954K, 10.1039/c5an01954k]
[10]   New ionization methods and miniature mass spectrometers for biomedicine: DESI imaging for cancer diagnostics and paper spray ionization for therapeutic drug monitoring [J].
Cooks, R. Graham ;
Manicke, Nicholas E. ;
Dill, Allison L. ;
Ifa, Demian R. ;
Eberlin, Livia S. ;
Costa, Anthony B. ;
Wang, He ;
Huang, Guangming ;
Zheng Ouyang .
FARADAY DISCUSSIONS, 2011, 149 :247-267