Inter-rater reliability of muscle contractile property measurements using non-invasive tensiomyography

被引:142
作者
Tous-Fajardo, Julio [1 ]
Moras, Gerard [1 ]
Rodriguez-Jimenez, Sergio [1 ]
Usach, Robert [1 ]
Doutres, Daniel Moreno [1 ]
Mafiuletti, Nicola A. [2 ]
机构
[1] Sports Sci Res Grp, INEFC Barcelona, Barcelona, Spain
[2] Schulthess Clin, Neuromuscular Res Lab, Zurich, Switzerland
关键词
Radial muscle belly displacement; Vastus medialis; Inter-electrodes distance; Contractile properties; MECHANOMYOGRAPHIC RESPONSES; ISOMETRIC CONTRACTION; PARAMETERS; ELECTROMYOGRAPHY; VOLUNTARY; TORQUE;
D O I
10.1016/j.jelekin.2010.02.008
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Tensiomyography (TMG) is a relatively novel technique to assess muscle mechanical response based on radial muscle belly displacement consecutive to a single electrical stimulus. Although intra-session reliability has been found to be good, inter-rater reliability and the influence of sensor repositioning and electrodes placement on TMG measurements is unknown. The purpose of this study was to analyze the inter-rater reliability of vastus medialis muscle contractile property measurements obtained with TMG as well as the effect of inter-electrode distance (IED). Five contractile parameters were analyzed from vastus medialis muscle belly displacement-time curves: maximal displacement (Dm), contraction time (Tc), sustain time (Ts), delay time (Td), and half-relaxation time (Tr). The inter-rater reliability and IED effect on these measurements were evaluated in 18 subjects. Intra-class correlation coefficients, standard errors of measurement, Bland and Altman systematic bias and random error as well as coefficient of variations were used as measures of reliability. Overall, a good to excellent inter-rater reliability was found for all contractile parameters, except Tr, which showed insufficient reliability. Alterations in IED significantly affected Dm with a trend for all the other parameters. The present results legitimate the use of TMG for the assessment of vastus medialis muscle contractile properties, particularly for Dm and Tc. It is recommended to avoid Tr quanti. cation and IED modi. cations during multiple TMG measurements. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:761 / 766
页数:6
相关论文
共 22 条
[1]   MAGNETIC-RESONANCE-IMAGING AND ELECTROMYOGRAPHY AS INDEXES OF MUSCLE FUNCTION [J].
ADAMS, GR ;
DUVOISIN, MR ;
DUDLEY, GA .
JOURNAL OF APPLIED PHYSIOLOGY, 1992, 73 (04) :1578-1589
[2]  
ALANEN AM, 1994, ACTA NEUROL SCAND, V89, P336
[3]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[4]  
Bergman BC, 2001, J STRENGTH COND RES, V15, P1
[5]   Properties of musculus gluteus maximus in above-knee amputees [J].
Burger, H ;
Valencic, V ;
Marincek, C ;
Kogovsek, N .
CLINICAL BIOMECHANICS, 1996, 11 (01) :35-38
[6]   Spatial fiber type distribution in normal human muscle - Histochemical and tensiomyographical evaluation [J].
Dahmane, R ;
Djordjevic, S ;
Simunic, B ;
Valencic, V .
JOURNAL OF BIOMECHANICS, 2005, 38 (12) :2451-2459
[7]   Evaluation of the ability to make non-invasive estimation of muscle contractile properties on the basis of the muscle belly response [J].
Dahmane, R ;
Valencic, V ;
Knez, N ;
Erzen, I .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2001, 39 (01) :51-55
[8]  
Delagi EF., 1975, Anatomic Guide For The Electromyographer The Limbs
[9]   Mechanomyographic responses to concentric isokinetic muscle contractions [J].
Evetovich, TK ;
Housh, TJ ;
Stout, JR ;
Johnson, GO ;
Smith, DB ;
Ebersole, KT .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1997, 75 (02) :166-169
[10]   Tendinous movement of a human muscle during voluntary contractions determined by real-time ultrasonography [J].
Fukunaga, T ;
Ito, M ;
Ichinose, Y ;
Kuno, S ;
Kawakami, Y ;
Fukashiro, S .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (03) :1430-1433