Effect of inclination angle on hooked end steel fiber pullout behavior in ultra-high performance concrete

被引:90
作者
Cao, Y. Y. Y. [1 ]
Yu, Q. L. [1 ]
机构
[1] Eindhoven Univ Technol, Dept Built Environm, POB 513, NL-5600 MB Eindhoven, Netherlands
关键词
Single-fiber pullout; Hooked end fiber; Ultra-high performance concrete; Inclination angle; Parametric evaluation; Pullout mechanism; REINFORCED CEMENTITIOUS COMPOSITES; MECHANICAL-PROPERTIES; IMPACT RESISTANCE; FLEXURAL BEHAVIOR; TENSILE BEHAVIOR; OUT BEHAVIOR; STRENGTH; MATRIX; UHPFRC; SHAPE;
D O I
10.1016/j.compstruct.2018.06.029
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The bond relationship between the concrete matrix and steel fiber is a significant factor that affects the performance of ultra-high performance fiber reinforced concrete (UHPFRC). In the present research, pullout performances of hooked end fibers embedded in ultra-high performance concrete matrix under various inclination angles are systematically investigated, with special attention on fiber dimension and embedded length. Pullout load-slip curves are obtained and experimental observations including complete fiber pull-out, fiber rupture and matrix failure are analyzed in detail. The effects of the pullout angle are then studied quantitatively by parameter calculations and mechanism analysis. A new analytical model for evaluating the snubbing and spalling effects of the hooked end steel fiber is proposed and validated. It is shown that the influences of the inclination angle on the peak pullout load vary with different fiber types, embedded lengths and fiber diameters, which are also associated with the occurrences of the fiber rupture and the matrix failure. In addition, optical microscope and scanning electron microscopy observations at mesoscale are performed to further analyze the effects of orientation angle.
引用
收藏
页码:151 / 160
页数:10
相关论文
共 45 条
[1]   Pull-Out Behaviour of Hooked End Steel Fibres Embedded in Ultra-high Performance Mortar with Various W/B Ratios [J].
Abdallah, Sadoon ;
Fan, Mizi ;
Zhou, Xiangming .
INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2017, 11 (02) :301-313
[2]  
[Anonymous], 2015, THESIS
[3]  
BANTHIA N, 1994, ACI MATER J, V91, P435
[4]  
FU SY, 1992, SMART MATER STRUCT, V1, P180
[5]   Experimental test methods to determine the uniaxial tensile and compressive behaviour of ultra high performance fibre reinforced concrete (UHPFRC) [J].
Hassan, A. M. T. ;
Jones, S. W. ;
Mahmud, G. H. .
CONSTRUCTION AND BUILDING MATERIALS, 2012, 37 :874-882
[6]   Analysis of steel fibers pull-out. Experimental study [J].
Isla, Facundo ;
Ruano, Gonzalo ;
Luccioni, Bibiana .
CONSTRUCTION AND BUILDING MATERIALS, 2015, 100 :183-193
[7]  
Johnston CD., 2001, Fiber-Reinforced Cements and Concretes
[8]   Comparative flexural behavior of Hybrid Ultra High Performance Fiber Reinforced Concrete with different macro fibers [J].
Kim, Dong Joo ;
Park, Seung Hun ;
Ryu, Gum Sung ;
Koh, Kyung Taek .
CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (11) :4144-4155
[9]  
Kim DJ, 2008, ACI MATER J, V105, P576
[10]   Influence of sand to coarse aggregate ratio on the interfacial bond strength of steel fibers in concrete for nuclear power plant [J].
Kim, Jung Jin ;
Kim, Dong Joo ;
Kang, Su Tae ;
Lee, Jang Hwa .
NUCLEAR ENGINEERING AND DESIGN, 2012, 252 :1-10