Removal of hydroquinone from water by electrocoagulation using flow cell and optimization by response surface methodology

被引:30
|
作者
Prabhakaran, D. [2 ]
Basha, C. A. [1 ]
Kannadasan, T. [3 ]
Aravinthan, P. [4 ]
机构
[1] CSIR, Cent Electrochem Res Inst, Karaikkudi 630006, Tamil Nadu, India
[2] Coimbatore Inst Technol, Coimbatore, Tamil Nadu, India
[3] Anna Univ Coimbatore, Res Ctr, Coimbatore, Tamil Nadu, India
[4] Covanta Samalpatti Operating Private Ltd, Safety Hlth & Environm Dept, Parandapalli Village, India
来源
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING | 2010年 / 45卷 / 04期
关键词
Hydroquinone; electrocoagulation; mono and bipolar flow cell; response surface method; TEXTILE WASTE-WATER; PHOTOCATALYTIC DEGRADATION; COAGULATION; SEPARATION; EFFLUENTS; CU2+;
D O I
10.1080/10934520903540174
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, hydroquinone was removed from water by electrocoagulation using flow electrolyzer in mono polar and bipolar configurations in a batch recirculation mode of operation. Treatment performances of such effluents have been evaluated in terms of chemical oxygen demand removal. The effect of important operating parameters such as current density, flow rate, concentration of hydroquinone and supporting electrolyte on the pollutant removal and energy consumption is critically evaluated. The experimental data were analyzed using response surface methodology (RSM). Maximum COD removal in monopolar configuration of 80.95% was noticed at condition of supporting electrolyte concentration 2.67 g L-1, flow rate 27 mL min(-1), current density 0.7 A dm(-2) at energy consumption of 2.36 kWh per kg of COD for the 1000 mg L-1 of hydroquinone concentration. In the case of bipolar configuration a maximum COD removal of 87.13 was noticed at: supporting electrolyte concentration 4 g L-1, flow rate 29.15 mL min(-1), current density 1 Adm(-2) at energy consumption of 8.495 kWh per kg of COD for the same hydroquinone concentration.
引用
收藏
页码:400 / 412
页数:13
相关论文
共 50 条
  • [21] Optimization of COD Removal from Pharmaceutical Wastewater by Electrocoagulation process using Response Surface Methodology (RSM)
    Najeeb, Riham Gh.
    Abbar, Ali H.
    EGYPTIAN JOURNAL OF CHEMISTRY, 2022, 65 (01): : 619 - 631
  • [22] Simultaneous removal of lead, chromium and cadmium from synthetic water by electrocoagulation: Optimization through response surface methodology
    Singh Thakur L.
    Baghel R.
    Sharma A.
    Sharma S.
    verma S.
    Parmar H.
    Kumar Varma A.
    Mondal P.
    Materials Today: Proceedings, 2023, 72 : 2697 - 2704
  • [23] Removal of Silica from Cooling Water by Electrocoagulation: A Comprehensive and Systematic Study Using Response Surface Methodology
    Zhi, S. L.
    Zhang, S. T.
    Lu, X. B.
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (16) : 9309 - 9314
  • [24] Removal of Cefixime from aqueous solutions via proxy electrocoagulation: modeling and optimization by response surface methodology
    Mahdi Asadi-Ghalhari
    Roqiyeh Mostafaloo
    Nasim Ghafouri
    Amin Kishipour
    Saideh Usefi
    Oussama Baaloudj
    Reaction Kinetics, Mechanisms and Catalysis, 2021, 134 : 459 - 471
  • [25] Arsenic Removal from Natural Groundwater by Electrocoagulation Using Response Surface Methodology
    Garcia-Lara, A. M.
    Montero-Ocampo, C.
    Equihua-Guillen, F.
    Camporredondo-Saucedo, J. E.
    Servin-Castaneda, R.
    Muniz-Valdes, C. R.
    JOURNAL OF CHEMISTRY, 2014, 2014
  • [26] Removal of chlorophyll and tannins from Anthocleista schweinfurthii Gilg leaves by electrocoagulation using iron electrodes: optimization using response surface methodology
    Tsopjio, Francine Nkouam
    Tchamango, Serge Raoul
    Momeni, Jean
    Monde, Gaye
    Tsopmejio, Jean Paul
    Ngassoum, Martin Benoit
    Darchen, Andre
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2020, 95 (07) : 2001 - 2008
  • [27] Optimization of boron removal from water by electrodialysis using response surface methodology
    Guesmi, Fatma
    Louati, Islem
    Hannachi, Chiraz
    Hamrouni, Bechir
    WATER SCIENCE AND TECHNOLOGY, 2020, 81 (02) : 293 - 300
  • [28] OPTIMIZATION OF COD REMOVAL FROM POLYVINYL ALCOHOL AQUEOUS SOLUTION VIA ELECTROCOAGULATION USING RESPONSE SURFACE METHODOLOGY
    Huang, Kai-Yu
    Shu, Chi-Min
    FRESENIUS ENVIRONMENTAL BULLETIN, 2014, 23 (1A): : 207 - 214
  • [29] OPTIMIZATION OF THE COMBINED UV/ELECTROCOAGULATION PROCESS FOR DYE REMOVAL FROM TEXTILE WASTEWATER USING RESPONSE SURFACE METHODOLOGY
    Pajootan, Elmira
    Arami, Mokhtar
    Bahrami, Hajir
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2016, 15 (01): : 189 - 198
  • [30] Evaluation of amoxicillin antibiotic removal by electrocoagulation process from aqueous solutions: optimization through response surface methodology
    Alidadi, Hosein
    Ghorbanian, Akram
    Ghorbanian, Mahdi
    Rahmanzadeh, Elham
    Nemanifar, Nasrin
    Mehrabpour, Marjan
    DESALINATION AND WATER TREATMENT, 2018, 132 : 350 - 358