Removal of hydroquinone from water by electrocoagulation using flow cell and optimization by response surface methodology

被引:30
|
作者
Prabhakaran, D. [2 ]
Basha, C. A. [1 ]
Kannadasan, T. [3 ]
Aravinthan, P. [4 ]
机构
[1] CSIR, Cent Electrochem Res Inst, Karaikkudi 630006, Tamil Nadu, India
[2] Coimbatore Inst Technol, Coimbatore, Tamil Nadu, India
[3] Anna Univ Coimbatore, Res Ctr, Coimbatore, Tamil Nadu, India
[4] Covanta Samalpatti Operating Private Ltd, Safety Hlth & Environm Dept, Parandapalli Village, India
来源
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING | 2010年 / 45卷 / 04期
关键词
Hydroquinone; electrocoagulation; mono and bipolar flow cell; response surface method; TEXTILE WASTE-WATER; PHOTOCATALYTIC DEGRADATION; COAGULATION; SEPARATION; EFFLUENTS; CU2+;
D O I
10.1080/10934520903540174
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, hydroquinone was removed from water by electrocoagulation using flow electrolyzer in mono polar and bipolar configurations in a batch recirculation mode of operation. Treatment performances of such effluents have been evaluated in terms of chemical oxygen demand removal. The effect of important operating parameters such as current density, flow rate, concentration of hydroquinone and supporting electrolyte on the pollutant removal and energy consumption is critically evaluated. The experimental data were analyzed using response surface methodology (RSM). Maximum COD removal in monopolar configuration of 80.95% was noticed at condition of supporting electrolyte concentration 2.67 g L-1, flow rate 27 mL min(-1), current density 0.7 A dm(-2) at energy consumption of 2.36 kWh per kg of COD for the 1000 mg L-1 of hydroquinone concentration. In the case of bipolar configuration a maximum COD removal of 87.13 was noticed at: supporting electrolyte concentration 4 g L-1, flow rate 29.15 mL min(-1), current density 1 Adm(-2) at energy consumption of 8.495 kWh per kg of COD for the same hydroquinone concentration.
引用
收藏
页码:400 / 412
页数:13
相关论文
共 50 条
  • [11] Optimization of oil removal from oily wastewater by electrocoagulation using response surface method
    Tir, Mohamed
    Moulai-Mostefa, Nadji
    JOURNAL OF HAZARDOUS MATERIALS, 2008, 158 (01) : 107 - 115
  • [12] Optimization and modelling using the response surface methodology (RSM) for ciprofloxacin removal by electrocoagulation
    Barisci, Sibel
    Turkay, Ozge
    WATER SCIENCE AND TECHNOLOGY, 2016, 73 (07) : 1673 - 1679
  • [13] Statistical Optimization of Electrocoagulation Process for Removal of Nitrates Using Response Surface Methodology
    Acharya, Sanigdha
    Sharma, S. K.
    Chauhan, Garima
    Shree, Darshan
    INDIAN CHEMICAL ENGINEER, 2018, 60 (03) : 269 - 284
  • [14] Optimization of As(III) removal in hard water by electrocoagulation using central composite design with response surface methodology
    Yaghmaeian, Kamyar
    Martinez, Susana Silva
    Hoseini, Mohammad
    Amiri, Hoda
    DESALINATION AND WATER TREATMENT, 2016, 57 (57) : 27827 - 27833
  • [15] Leachate effluent COD removal using electrocoagulation: a response surface methodology (RSM) optimization and modeling
    Rabahi, Amel
    Hauchard, Didier
    Arris, Sihem
    Berkani, Mohammed
    Achouri, Ouafa
    Meniai, Abdeslam Hassen
    Bencheikh-Lehocine, Mossaab
    DESALINATION AND WATER TREATMENT, 2018, 114 : 81 - 92
  • [16] Uranium removal from Pyhasalmi/Finland mine water by batch electrocoagulation and optimization with the response surface methodology
    Nariyan, Elham
    Sillanpaa, Mika
    Wolkersdorfer, Christian
    SEPARATION AND PURIFICATION TECHNOLOGY, 2018, 193 : 386 - 397
  • [17] Electrocoagulation for Cyanide Removal from Industrial Waste Solutions: an Innovative Cell Design and Optimization Using Response Surface Methodology
    D.G. Bassyouni
    M. H. Abdel-Aziz
    E-S.Z. El-Ashtoukhy
    G. H. Sedahmed
    I. A. El-Gheriany
    Water, Air, & Soil Pollution, 2023, 234
  • [18] Arsenite removal from groundwater in a batch electrocoagulation process: Optimization through response surface methodology
    Demirbas, Erhan
    Kobya, Mehmet
    Oncel, Mehmet Salim
    Sik, Emrah
    Goren, Aysegul Yagmur
    SEPARATION SCIENCE AND TECHNOLOGY, 2019, 54 (05) : 775 - 785
  • [19] Electrocoagulation for Cyanide Removal from Industrial Waste Solutions: an Innovative Cell Design and Optimization Using Response Surface Methodology
    Bassyouni, D. G.
    Abdel-Aziz, M. H.
    El-Ashtoukhy, E-s. z.
    Sedahmed, G. H.
    El-Gheriany, I. A.
    WATER AIR AND SOIL POLLUTION, 2023, 234 (11)
  • [20] Statistical optimization of nitrocellulose removal from industrial wastewater by electrocoagulation using response surface method
    Pouretedal, Hamid Reza
    Shamsi, Mehdi
    Arabiyan, Darush
    DESALINATION AND WATER TREATMENT, 2021, 212 : 212 - 219