Background: Uncontrolled hemorrhage accounts for the majority of deaths in combat. Effective topical hemostatic agents suitable for use on the battlefield may be valuable in controlling hemorrhage until definitive surgical intervention is possible. In an effort to identify a hemostatic agent suitable for battlefield use, we evaluated several potential hemostatic agents in a swine injury model and noted thermal injury to tissues with a granular mineral hemostatic agent (QuikClot(TM)). Methods: Anesthetized swine were maintained with a mean arterial pressure in excess of 60 min Hg. Cutaneous, muscular, hepatic, splenic, venous, and arterial wounds were created in a standardized fashion. Topical hemostatic agents were immediately applied to the wounds and the amount of bleeding and time to hemostasis were noted. Results: The results reported here are part of a larger study in which a variety of hemostatic agents were evaluated. Only the findings related to the granular mineral hemostatic agent are discussed here. Application of the agent resulted in elevated tissue surface temperatures in excess of 95degreesC and internal tissue temperatures exceeding 50degreesC, 3 mm. deep to the bleeding surface. Necrosis of fat and muscle were noted as well as full and partial thickness cutaneous burns. Conclusions: Topical administration of a granular mineral hemostatic agent to a variety of wounds in an experimental swine model resulted in thermal tissue injury and necrosis. Suggestions for reducing the extent of injury with this product are offered.
引用
收藏
页码:224 / 230
页数:7
相关论文
共 16 条
[1]  
ABBOTT WM, 1974, SURGERY, V75, P925
[2]   Comparative analysis of hemostatic agents in a swine model of lethal groin injury [J].
Alam, HB ;
Uy, GB ;
Miller, D ;
Koustova, E ;
Hancock, T ;
Inocencio, R ;
Anderson, D ;
Llorente, O ;
Rhee, P .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2003, 54 (06) :1077-1082
[3]  
CAMERON WJ, 1978, OBSTET GYNECOL, V51, P118
[4]  
CANTRILL SV, 2002, ROSENS EMERGENCY MED, P314
[5]  
HARRIS WH, 1978, J BONE JOINT SURG AM, V60, P454, DOI 10.2106/00004623-197860040-00004
[6]  
HENSEL JF, 2002, HEMCOM FDA 501 5 SUM
[7]  
HURSEY FX, 2002, FDA 510 K SUMMARY
[8]   United States Army rangers in Somalia: An analysis of combat casualties on an urban battlefield [J].
Mabry, RL ;
Holcomb, JB ;
Baker, AM ;
Cloonan, CC ;
Uhorchak, JM ;
Perkins, DE ;
Canfield, AJ ;
Hagmann, JH .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2000, 49 (03) :515-528
[9]  
MALVIYA VK, 1989, OBSTET GYNECOL, V73, P284
[10]   Allergic reactions to oral, surgical and topical bovine collagen - Anaphylactic risk for surgeons [J].
Mullins, RJ ;
Richards, C ;
Walker, T .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1996, 24 (03) :257-260