Efficacy and Safety of High-Viscosity Bone Cement Vertebroplasty in Treatment of Osteoporotic Vertebral Compression Fractures with Intravertebral Cleft

被引:20
作者
Tang, Shenghui [1 ]
Fu, Wangjun [1 ]
Zhang, Hongda [1 ]
Zhang, Haonan [1 ]
Liang, Biru [1 ]
机构
[1] Southern Med Univ, Affiliated Hosp 5, Dept Orthopaed, Guangzhou, Guangdong, Peoples R China
关键词
Cement leakage; High-viscosity cement; Intravertebral cleft; Low-viscosity cement; Osteoporotic vertebral compression fractures; Percutaneous vertebroplasty; PERCUTANEOUS VERTEBROPLASTY; BALLOON KYPHOPLASTY; VACUUM CLEFT; OUTCOMES; SIGN;
D O I
10.1016/j.wneu.2019.08.029
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To evaluate and compare clinical outcomes and cement leakage of high-viscosity bone cement versus low-viscosity bone cement vertebroplasty in treating osteoporotic vertebral compression fractures with intravertebral cleft. METHODS: The study included 72 patients with osteoporotic vertebral compression fractures with intravertebral cleft, who were divided into high-viscosity cement (HVC) (38 cases) and low-viscosity cement (LVC) (34 cases) groups according to the viscosity of bone cement used. Cement leakage, visual analog scale score, Oswestry Disability Index, and kyphotic angle (KA) were evaluated. RESULTS: All patients were followed for at least 12 months. Overall cement leakage rate was 18.4% in the HVC group, lower than the rate of 61.8% obtained in the LVC group. A statistically significant difference was found in the overall cement leakage rate between the groups (P < 0.05). Visual analog scale and Oswestry Disability Index scores were significantly improved after percutaneous vertebroplasty without significant differences between the HVC and LVC groups (P > 0.05). The KA of patients from both groups was also significantly corrected immediately after surgery. Although the KA gradually increased in both groups during the follow-up period, there was no statistically significant difference between the HVC and LVC groups in KA during follow-up (P > 0.05). CONCLUSIONS: Percutaneous vertebroplasty using HVC to treat osteoporotic vertebral compression fractures with intravertebral cleft significantly reduces cement leakage and improves the safety of the operation. In terms of clinical efficacy and prevention of augmented vertebral recollapse, HVC may not have obvious advantages.
引用
收藏
页码:E739 / E745
页数:7
相关论文
共 32 条
[1]   Coexistence of intravertebral vacuum and intradiscal vacuum [J].
Armingeat, Thomas ;
Pham, Thao ;
Legre, Virginie ;
Lafforgue, Pierre .
JOINT BONE SPINE, 2006, 73 (04) :428-432
[2]   High-viscosity cement significantly enhances uniformity of cement filling in vertebroplasty: An experimental model and study on cement leakage [J].
Baroud, Gamal ;
Crookshank, Meghan ;
Bohner, Marc .
SPINE, 2006, 31 (22) :2562-2568
[3]   Percutaneous balloon kyphoplasty of osteoporotic vertebral compression fractures with intravertebral cleft [J].
Chen, Bao ;
Fan, Shunwu ;
Zhao, Fengdong .
INDIAN JOURNAL OF ORTHOPAEDICS, 2014, 48 (01) :53-59
[4]   Vertebral fluid collection associated with vertebral collapse [J].
Dupuy, DE ;
Palmer, WE ;
Rosenthal, DI .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (06) :1535-1538
[5]  
Fang XT, 2015, INT J CLIN EXP MED, V8, P16960
[6]   Clinical Experience with High-Viscosity Cements for Percutaneous Vertebral Body Augmentation: Occurrence, Degree, and Location of Cement Leakage Compared with Kyphoplasty [J].
Georgy, B. A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (03) :504-508
[7]  
Georgy B, 2013, PAIN PHYSICIAN, V16, pE513
[8]   Treating osteoporotic vertebral compression fractures with intraosseous vacuum phenomena using high-viscosity bone cement via bilateral percutaneous vertebroplasty [J].
Guo, Dan ;
Cai, Jun ;
Zhang, Shengfei ;
Zhang, Liang ;
Feng, Xinmin .
MEDICINE, 2017, 96 (14)
[9]   Percutaneous vertebroplasty for vertebral compression fractures with and without intravertebral clefts [J].
Ha, K. -Y. ;
Lee, J. -S. ;
Kim, K. -W. ;
Chon, J. -S. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (05) :629-633
[10]   Intravertebral vacuum phenomenon in osteoporotic compression fracture: report of 67 cases with quantitative evaluation of intravertebral instability [J].
Kim, DY ;
Lee, SH ;
Jang, JS ;
Chung, SK ;
Lee, HY .
JOURNAL OF NEUROSURGERY, 2004, 100 (01) :24-31