Background: The computed tomography (CT) scan delivers a relatively high radiation dose to the patient. One of the critical factors that affects the absorbed dose is the intensity of tube current. The aim of this study is to measure and compare the radiation dose of three radiation-sensitive organs in constant current mode and tube current modulation (TCM) modes. Materials and Methods: CT-scans from the chest and abdomen-pelvis regions of adults in three different current modes were obtained. The absorbed doses of thyroid, lungs, and ovaries were measured using the thermoluminescent dosimeter (TLD) chips embedded in the RANDO phantom. Furthermore, the confirmation of the organ doses was simulated using the Monte Carlo (MC) simulation. The measured doses were evaluated and confirmed by comparison with the simulated doses. Results: The relative differences between the measured and simulated doses for thyroid, lung, and ovary were -4.7%, -1.3%, and -11.7% for constant current mode, -2.2%, -11.2%, and -6.3% for longitudinal modulation mode, and 0.0%, -14.6%, and -9.9% for angular modulation mode, respectively. With longitudinal modulation mode, thyroid, lung, and ovary doses were reduced by 34.0%, 19.0%, and 19.0% for the measured doses and 32.0%, 26.0%, and 13.0% for the simulated doses, respectively. The longitudinal modulation mode resulted in a greater dose reduction compared to the angular modulation for both measured and simulated doses. Conclusion: Using TCM resulted in reducing does received by the organs in both measured and simulated doses. The TCM reduces organ dose, which is more evident in the longitudinal modulation.
引用
收藏
页码:575 / 581
页数:7
相关论文
共 50 条
  • [1] ORGAN DOSE EVALUATIONS BASED ON MONTE CARLO SIMULATION FOR CT EXAMINATIONS USING TUBE CURRENT MODULATION
    Fujii, K.
    Nomura, K.
    Muramatsu, Y.
    Obara, S.
    Akahane, K.
    Kusumoto, M.
    RADIATION PROTECTION DOSIMETRY, 2017, 174 (03) : 387 - 394
  • [2] A new Monte Carlo tool for organ dose estimation in computed tomography
    Adrien, C.
    Le Loirec, C.
    Dreuil, S.
    Bordy, J. -M.
    RADIOPROTECTION, 2020, 55 (02) : 123 - 134
  • [3] Organ doses evaluation for chest computed tomography procedures with TL dosimeters: Comparison with Monte Carlo simulations
    Giansante, Louise
    Martins, Juliana C.
    Nersissian, Denise Y.
    Kiers, Karen C.
    Kay, Fernando U.
    Sawamura, Marcia V. Y.
    Lee, Choonsik
    Gebrim, Eloisa M. M. S.
    Costa, Paulo R.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 308 - 320
  • [4] Physical validation of a Monte Carlo-based, phantom-derived approach to computed tomography organ dosimetry under tube current modulation
    Stepusin, Elliott J.
    Long, Daniel J.
    Ficarrotta, Kayla R.
    Hintenlang, David E.
    Bolch, Wesley E.
    MEDICAL PHYSICS, 2017, 44 (10) : 5423 - 5432
  • [5] Assessment of an organ-based tube current modulation in thoracic computed tomography
    Matsubara, Kosuke
    Sugai, Mai
    Toyoda, Asami
    Koshida, Haruka
    Sakuta, Keita
    Takata, Tadanori
    Koshida, Kichiro
    Iida, Hiroji
    Matsui, Osamu
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (02): : 148 - 158
  • [6] Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation
    Mohammadi, Gh. R. Fallah
    Alam, N. Riyahi
    Geraily, Gh.
    Paydar, R.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (04): : 313 - 321
  • [7] Monte Carlo simulation of eye lens dose reduction from CT scan using organ based tube current modulation
    Huang, Ying
    Zhuo, Weihai
    Gao, Yiming
    Liu, Haikuan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 48 : 72 - 75
  • [8] Evaluating the Organ Dose From Computed Tomography Using Monte Carlo Calculations
    Ono, T.
    Araki, F.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [9] Monte Carlo Simulation of the Computed Tomography Dose Index (CTDI) Using GATE
    Mkimel, M.
    El Baydaoui, R.
    Mesradi, M. R.
    Tahiri, Z.
    Talasmat, K.
    Halimi, A.
    Krim, M.
    Saad, E.
    Hilali, A.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2020, 17 (06) : 900 - 907
  • [10] Organ dose in cardiac dual-energy computed tomography: a Monte Carlo study
    Delaram Pakravan
    Farshid Babapour Mofrad
    Mohammad Reza Deevband
    Mahdi Ghorbani
    Hamidreza Pouraliakbar
    Physical and Engineering Sciences in Medicine, 2022, 45 : 157 - 166