Estimating organ dose in computed tomography using tube current modulation: A Monte Carlo simulation

被引:3
|
作者
Hosseinzadeh, V [1 ]
Ghaffari, H. [2 ]
Rezaeyan, A. [2 ]
Deilami, S. [3 ]
机构
[1] Islamic Azad Univ, Dept Nucl Engn, Arsanjan Branch, Arsanjan, Iran
[2] Iran Univ Med Sci, Sch Med, Dept Med Phys, Tehran, Iran
[3] Islamic Azad Univ, Dept Phys, Arsanjan Branch, Arsanjan, Iran
来源
关键词
Computed tomography; tube current modulation; organ dose; thermoluminsent dosimeter; Monte Carlo simulation; CT EXAMINATIONS; CANCER-RISK; VALIDATION; REDUCTION; ADULT; SCAN;
D O I
10.18869/acadpub.ijrr.19.3.575
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The computed tomography (CT) scan delivers a relatively high radiation dose to the patient. One of the critical factors that affects the absorbed dose is the intensity of tube current. The aim of this study is to measure and compare the radiation dose of three radiation-sensitive organs in constant current mode and tube current modulation (TCM) modes. Materials and Methods: CT-scans from the chest and abdomen-pelvis regions of adults in three different current modes were obtained. The absorbed doses of thyroid, lungs, and ovaries were measured using the thermoluminescent dosimeter (TLD) chips embedded in the RANDO phantom. Furthermore, the confirmation of the organ doses was simulated using the Monte Carlo (MC) simulation. The measured doses were evaluated and confirmed by comparison with the simulated doses. Results: The relative differences between the measured and simulated doses for thyroid, lung, and ovary were -4.7%, -1.3%, and -11.7% for constant current mode, -2.2%, -11.2%, and -6.3% for longitudinal modulation mode, and 0.0%, -14.6%, and -9.9% for angular modulation mode, respectively. With longitudinal modulation mode, thyroid, lung, and ovary doses were reduced by 34.0%, 19.0%, and 19.0% for the measured doses and 32.0%, 26.0%, and 13.0% for the simulated doses, respectively. The longitudinal modulation mode resulted in a greater dose reduction compared to the angular modulation for both measured and simulated doses. Conclusion: Using TCM resulted in reducing does received by the organs in both measured and simulated doses. The TCM reduces organ dose, which is more evident in the longitudinal modulation.
引用
收藏
页码:575 / 581
页数:7
相关论文
共 50 条
  • [1] ORGAN DOSE EVALUATIONS BASED ON MONTE CARLO SIMULATION FOR CT EXAMINATIONS USING TUBE CURRENT MODULATION
    Fujii, K.
    Nomura, K.
    Muramatsu, Y.
    Obara, S.
    Akahane, K.
    Kusumoto, M.
    RADIATION PROTECTION DOSIMETRY, 2017, 174 (03) : 387 - 394
  • [2] Combined Organ Dose for Digital Subtraction Angiography and Computed Tomography Using Monte Carlo Simulation
    Sakabe, D.
    Ohno, T.
    Araki, F.
    Hashida, M.
    Funama, Y.
    MEDICAL PHYSICS, 2016, 43 (06) : 3777 - 3777
  • [3] Monte Carlo simulation of eye lens dose reduction from CT scan using organ based tube current modulation
    Huang, Ying
    Zhuo, Weihai
    Gao, Yiming
    Liu, Haikuan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 48 : 72 - 75
  • [4] Evaluating the Organ Dose From Computed Tomography Using Monte Carlo Calculations
    Ono, T.
    Araki, F.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [5] Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation
    Mohammadi, Gh. R. Fallah
    Alam, N. Riyahi
    Geraily, Gh.
    Paydar, R.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (04): : 313 - 321
  • [6] Monte Carlo Simulation and Dose Calculation of Chest CT Scan with Tube Current Modulation
    Gao, Y.
    Ding, A.
    Zhang, D.
    Liu, B.
    Caracappa, P.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [7] Estimation of Computed Tomography Dose Index (CTDI) Using Monte Carlo Simulation
    Talbi, Mohammed
    Aabid, Mohammed
    El Mansouri, M'hamed
    Nhila, Oussama
    Semghouli, Slimane
    Sebihi, Rajaa
    Choukri, Abdelmajid
    Khalis, Mohammed
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2021, 76 (SUPPL 1) : S103 - S109
  • [8] Estimation of Computed Tomography Dose Index (CTDI) Using Monte Carlo Simulation
    Mohammed Talbi
    Mohammed Aabid
    M’hamed El Mansouri
    Oussama Nhila
    Slimane Semghouli
    Rajaa Sebihi
    Abdelmajid Choukri
    Mohammed Khalis
    Moscow University Physics Bulletin, 2021, 76 : S103 - S109
  • [9] Monte Carlo Simulation of the Computed Tomography Dose Index (CTDI) Using GATE
    Mkimel, M.
    El Baydaoui, R.
    Mesradi, M. R.
    Tahiri, Z.
    Talasmat, K.
    Halimi, A.
    Krim, M.
    Saad, E.
    Hilali, A.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2020, 17 (06) : 900 - 907
  • [10] Monte Carlo Simulation of the Computed Tomography Dose Index (CTDI) Using GATE
    M. Mkimel
    R. El Baydaoui
    M. R. Mesradi
    Z. Tahiri
    K. Talasmat
    A. Halimi
    M. Krim
    E. Saad
    A. Hilali
    Physics of Particles and Nuclei Letters, 2020, 17 : 900 - 907