DEVELOPMENT OF A MICRO-COMPUTED TOMOGRAPHY-BASED IMAGE-GUIDED CONFORMAL RADIOTHERAPY SYSTEM FOR SMALL ANIMALS

被引:59
作者
Zhou, Hu [1 ]
Rodriguez, Manuel [1 ]
van den Haak, Fred [1 ]
Nelson, Geoffrey [1 ]
Jogani, Rahil [1 ]
Xu, Jiali [3 ]
Zhu, Xinzhi [3 ]
Xian, Yongjiang [4 ]
Tran, Phuoc T. [1 ]
Felsher, Dean W. [2 ]
Keall, Paul J. [1 ]
Graves, Edward E. [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Mol Imaging Program Stanford, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Med, Mol Imaging Program Stanford, Stanford, CA 94305 USA
[3] PheniCo Inc, Fremont, CA USA
[4] Bright Star Machine, Fremont, CA USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2010年 / 78卷 / 01期
关键词
Mouse models; Radiotherapy; Image guidance; MicroCT; RAT LUNG IRRADIATION; EARLY DNA-DAMAGE; RADIATION; MODEL; THERAPY;
D O I
10.1016/j.ijrobp.2009.11.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To report on the physical aspects of a system in which radiotherapy functionality was added to a micro-computed tomography (microCT) scanner, to evaluate the accuracy of this instrument, and to and demonstrate the application of this technology for irradiating tumors growing within the lungs of mice. Methods and Materials: A GE eXplore RS120 microCT scanner was modified by the addition of a two-dimensional subject translation stage and a variable aperture collimator. Quality assurance protocols for these devices, including measurement of translation stage positioning accuracy, collimator aperture accuracy, and collimator alignment with the X-ray beam, were devised. Use of this system for image-guided radiotherapy was assessed by irradiation of a solid water phantom as well as of two mice bearing spontaneous MYC-induced lung tumors. Radiation damage was assessed ex vivo by immunohistochemical detection of gamma H2AX foci. Results: The positioning error of the translation stage was found to be < 0.05 mm, whereas after alignment of the collimator with the X-ray axis through adjustment of its displacement and rotation, the collimator aperture error was < 0.1 mm measured at isocenter. Computed tomography image-guided treatment of a solid water phantom demonstrated target localization accuracy to within 0.1 mm. Gamma-H2AX foci were detected within irradiated lung tumors in mice, with contralateral lung tissue displaying background staining. Conclusions: Addition of radiotherapy functionality to a microCT scanner is an effective means of introducing image-guided radiation treatments into the preclinical setting. This approach has been shown to facilitate small-animal conformal radiotherapy while leveraging existing technology. (C) 2010 Elsevier Inc.
引用
收藏
页码:297 / 305
页数:9
相关论文
共 15 条
[1]  
Boone John M, 2004, Mol Imaging, V3, P149, DOI 10.1162/1535350042380326
[2]   Design and evaluation of a variable aperture collimator for conformal radiotherapy of small animals using a microCT scanner [J].
Graves, Edward E. ;
Zhou, Hu ;
Chatterjee, Raja ;
Keall, Paul J. ;
Gambhir, Sanjiv Sam ;
Contag, Christopher H. ;
Boyer, Arthur L. .
MEDICAL PHYSICS, 2007, 34 (11) :4359-4367
[3]   RT_Image: An open-source tool for investigating PET in radiation oncology [J].
Graves, Edward E. ;
Quon, Andrew ;
Loo, Billy W., Jr. .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2007, 6 (02) :111-121
[4]  
Hillman GG, 2001, CLIN CANCER RES, V7, P136
[5]   Progression of renal cell carcinoma is inhibited by genistein and radiation in an orthotopic model [J].
Hillman, Gilda G. ;
Wang, Yu ;
Che, Mingxin ;
Raffoul, Julian J. ;
Yudelev, Mark ;
Kucuk, Omer ;
Sarkar, Fazlul H. .
BMC CANCER, 2007, 7 (1)
[6]   Partial volume rat lung irradiation: An evaluation of early DNA damage [J].
Khan, MA ;
Hill, RP ;
Van Dyk, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (02) :467-476
[7]   Partial volume rat lung irradiation; assessment of early DNA damage in different lung regions and effect of radical scavengers [J].
Khan, MA ;
Van Dyk, J ;
Yeung, IWT ;
Hill, RP .
RADIOTHERAPY AND ONCOLOGY, 2003, 66 (01) :95-102
[8]   OVERVIEW OF ANIMAL STUDIES COMPARING RADIOIMMUNOTHERAPY WITH DOSE EQUIVALENT EXTERNAL BEAM IRRADIATION [J].
KNOX, SJ ;
GORIS, ML ;
WESSELS, BW .
RADIOTHERAPY AND ONCOLOGY, 1992, 23 (02) :111-117
[9]   BEAM ALIGNMENT TESTS FOR THERAPY ACCELERATORS [J].
LUTZ, WR ;
LARSEN, RD ;
BJARNGARD, BE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (12) :1727-1731
[10]  
RODRIGUEZ M, PHYS MED BI IN PRESS