Clinical trial evaluating a new hub device designed to prevent catheter-related sepsis

被引:24
作者
Luna, J
Masdeu, G
Pérez, M
Claramonte, R
Forcadell, I
Barrachina, F
Panisello, M
机构
[1] Hosp Tortosa Verge Cinta, Intens Care Unit, Serv Med Intens, Tortosa 43500, Spain
[2] Hosp Tortosa Verge Cinta, Dept Microbiol, Tortosa, Spain
关键词
D O I
10.1007/s100960000346
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
A new commercial hub device designed to minimise catheter-related infections was evaluated in a prospective, randomised trial in the intensive care and surgical units of the Hospital de Tortosa Verge de la Cinta in patients in whom the central venous catheters were expected to remain indwelling for at least 7 days. The assessments conducted at catheter withdrawal included cultures of the skin at the catheter site and cultures of the catheter tip and the catheter hubs; moreover, in cases of suspected catheter-related sepsis, samples of peripheral blood and infusion solutions were also cultured. Of the 130 catheters evaluated, 26 (20%) were withdrawn because of suspected catheter-related sepsis 10 (15%) were in the control group and 16 (24%) in the new product group. Catheter-related sepsis was diagnosed in nine patients, six of whom were in the new product group and three in the control group; all infections in the former group and only one in the latter group were caused by the catheter connection. The rates of catheter hub colonisation (10 cfu) and catheter colonisation (15 cfu in semiquantitative culture and/or >1000 cfu in quantitative culture) of hub origin were not significantly different between the groups (15 cases in the control group vs. 20 cases in the new product group, and 5 cases in the control group vs. 11 cases in the new product group, respectively). The data indicate that the use of the new catheter hub device is no more effective in preventing catheter-related infection than standard good clinical procedures.
引用
收藏
页码:655 / 662
页数:8
相关论文
共 28 条
[1]  
[Anonymous], 1998, HOSP INFECT
[2]   Serial surveillance cultures of skin and catheter hub specimens from critically ill patients with central venous catheters: Molecular epidemiology of infection and implications for clinical management and research [J].
Atela, I ;
Coll, P ;
Rello, J ;
Quintana, E ;
Barrio, J ;
March, F ;
Sanchez, F ;
Barraquer, P ;
Ballus, J ;
Cotura, A ;
Prats, G .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (07) :1784-1790
[3]   DIAGNOSIS OF CENTRAL VENOUS CATHETER-RELATED SEPSIS - CRITICAL-LEVEL OF QUANTITATIVE TIP CULTURES [J].
BRUNBUISSON, C ;
ABROUK, F ;
LEGRAND, P ;
HUET, Y ;
LARABI, S ;
RAPIN, M .
ARCHIVES OF INTERNAL MEDICINE, 1987, 147 (05) :873-877
[4]   QUANTITATIVE CULTURE OF INTRAVENOUS CATHETERS AND OTHER INTRAVASCULAR INSERTS [J].
CLERI, DJ ;
CORRADO, ML ;
SELIGMAN, SJ .
JOURNAL OF INFECTIOUS DISEASES, 1980, 141 (06) :781-787
[5]   A PROSPECTIVE, RANDOMIZED STUDY COMPARING TRANSPARENT AND DRY GAUZE DRESSINGS FOR CENTRAL VENOUS CATHETERS [J].
CONLY, JM ;
GRIEVES, K ;
PETERS, B .
JOURNAL OF INFECTIOUS DISEASES, 1989, 159 (02) :310-319
[6]   Novel approach to investigate a source of microbial contamination of central venous catheters [J].
Elliott, TSJ ;
Moss, HA ;
Tebbs, SE ;
Wilson, IC ;
Bonser, RS ;
Graham, TR ;
Burke, LP ;
Faroqui, MH .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1997, 16 (03) :210-213
[7]   CROSS-SECTIONAL EPIDEMIOLOGY OF PHLEBITIS AND CATHETER-RELATED INFECTIONS [J].
ENA, J ;
CERCENADO, E ;
MARTINEZ, D ;
BOUZA, E .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 1992, 13 (01) :15-20
[8]  
HALPIN DP, 1991, NUTRITION, V7, P33
[9]  
HOLM I, 1977, ACTA CHIR SCAND, V143, P297
[10]  
LEON MA, 1993, MED INTENSIVA, V17, P531